Skip to main content

Pre-launch Calibration of the Tiangong-2 Front-Azimuth Broadband Hyperspectrometer

  • Conference paper
  • First Online:
Proceedings of the Tiangong-2 Remote Sensing Application Conference

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 541))

  • 635 Accesses

Abstract

The Front-Azimuth Broadband Hyperspectrometer was launched on board the Tiangong-2 Space Laboratory on 15 Sep 2016 and had successfully measured spectral radiance of Earth limb atmosphere, to provide profiles of the volumetric concentration of ozone, nitrogen dioxide and other minor trace gases. In order to ensure the high accuracy and stability of data, The Front-Azimuth Broadband Hyperspectrometer was calibrated in laboratory and in orbit accurately. This paper mainly introduced the facility, method and results of the pre-launch calibration. Finally, the uncertainty of the calibration results was analyzed, and the results met the requirements of the data application.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Werij, H., Kruizinga, B., Olij, C., et al.: Calibration aspects of remote sensing spaceborne spectrometer. In: SPIE, vol. 2820, pp. 126–137 (1996)

    Google Scholar 

  2. Frerick, J., Bovensmann, H., Noel, S., et al.: SCIAMACHY on-ground/in-flight calibration, performance verification and monitoring concepts. In: SPIE, vol. 3117, pp. 176–187 (1997)

    Google Scholar 

  3. Ruyten, W.: Smear correction for frame transfer charge-coupled-device cameras. Opt. Lett. 24(13), 878–880 (1999)

    Article  Google Scholar 

  4. Barducci, A., Mecocci, A.: Theoretical and experimental assessment of noise effects on least-squares spectral unmixing of hyperspectral images. Opt. Eng. 44(8), 087008-1–087008-17 (2005)

    Article  Google Scholar 

  5. Zhang, R., Bayanheshig, Yin, L., et al.: Wavelength calibration model for prism-type echelle spectrometer by reversely solving prism’s refractive index in real time. Appl. Opt. 55(15), 4153–4158 (2016)

    Article  Google Scholar 

  6. Yokoya, N., Miyamura, N., Iwasaki, A.: Preprocessing of hyperspectral imagery with consideration of smile and keystone properties. In: SPIE, vol. 7857, pp. 78570B-1–78570B-9 (2010)

    Google Scholar 

  7. Zhanfeng, L.: Spectral stray light correction of forward limb imaging spectrometer. http://kns.cnki.net/kcms/detail/31.1252.O4.20180627.1743.054.html (2018)

  8. Tarrant, A.W.S.: Optical techniques for studying stray light in spectrophotometers. Opt. Acta 25(12), 1167–1174 (1978)

    Article  Google Scholar 

  9. Heath D.F., Wei Z., Fowler W.K.: Comparability of spectral radiance calibrations of large aperture earth observing instruments based upon diffuse reflective panels and internally illuminated spherical integrator techniques. In: SPIE, vol. 2209, pp. 148–159 (1994)

    Google Scholar 

Download references

Acknowledgements

Thanks to China Manned Space Engineering for providing space science and application data products of Tiangong-2.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shurong Wang .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Li, Z., Wang, S., Huang, Y., Ma, Q., Xue, Q., Li, Z. (2019). Pre-launch Calibration of the Tiangong-2 Front-Azimuth Broadband Hyperspectrometer. In: Gu, Y., Gao, M., Zhao, G. (eds) Proceedings of the Tiangong-2 Remote Sensing Application Conference. Lecture Notes in Electrical Engineering, vol 541. Springer, Singapore. https://doi.org/10.1007/978-981-13-3501-3_5

Download citation

  • DOI: https://doi.org/10.1007/978-981-13-3501-3_5

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-13-3500-6

  • Online ISBN: 978-981-13-3501-3

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics