Abstract
This paper focuses on thyristor in the aspects of its junction temperature, its zero di/dt, its forward current IT and its reverse voltage Vr, and presents in-depth study of internal factors which cause commutation failure of the valve. This paper puts forward the optimal configuration approach to the factors above, reduces various improvement measures to induce thyristor turn off time. A physical test platform of the shutdown characteristics is built. By testing the shutdown characteristics of thyristor, the linear regression analysis method is used to get the fitting formula of the thyristor turn off time.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Zheng B, Ricai G (2003) The development of interconnected power grid China. Power Grid Technol 27(2):1–3
Chao Z (2004) The role of HVDC transmission in the development of China’s power grid. High Voltage Technol 30(11):11–12
Shang C (2006) Application and application of UHV transmission technology in China southern power grid. High Voltage Technol 32(1):35–37
Fang X, Zhong S, Chen Z et al (2006) Study on access system of Zhuzhou converter station in Zhuzhou ±800 kV HVDC project. China Electr Power 39(3):50–54
Yinbiao S (2005) Development and implementation of UHV transmission in China. China Electr Power 38(11):1–8
Wang M (2003) Application of modern new technology in HVDC. Int Electr 7(2):32–34
Liu H, Xu Z (2002) Review of reliability of world long - distance high - capacity HVDC project. High Voltage Apparatus 38(3):26–28
Wang W (2004) HVDC engineering technology. China Electric Power Press, Beijing
Yang X, Chen H, Jin X (2006) Research on dynamic recovery characteristics of HVDC transmission system. High Voltage Technol 32(9):11–14
Ren Z, Chen Y, Zhensheng L et al (2004) Probabilistic analysis of commutation failure of HVDC transmission system. Autom Electr Power Syst 28(24):19–22
Zheng C, Huang L, Lin G et al (2011) RTO simulation of ±800 kV UHVDC commutation failure and its subsequent control and protection characteristics. Power System Technol 35(4):14–20
Acknowledgements
This work was supported by National Power Grid Corp science and technology project: Study on Ultra High Voltage Bypass Impedance Topology.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Zhang, Z., Zhang, L., Shou, Z., Jin, Y., Tan, Y. (2018). Test and Regression Analysis of Dynamic Shutdown Characteristic of High Power Thyristor. In: Jia, L., Qin, Y., Suo, J., Feng, J., Diao, L., An, M. (eds) Proceedings of the 3rd International Conference on Electrical and Information Technologies for Rail Transportation (EITRT) 2017. EITRT 2017. Lecture Notes in Electrical Engineering, vol 482. Springer, Singapore. https://doi.org/10.1007/978-981-10-7986-3_33
Download citation
DOI: https://doi.org/10.1007/978-981-10-7986-3_33
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-7985-6
Online ISBN: 978-981-10-7986-3
eBook Packages: EnergyEnergy (R0)