Determination of Glucose and Continuous Glucose Monitoring

  • Chapter
  • First Online:
  • 1402 Accesses

Abstract

Glucose is the main source of energy for human activities. Diabetes is a group of disorders characterized by chronic elevation of blood glucose. Thus, determination of blood glucose is a basic method for the diagnosis, treatment, and follow-up of diabetes. In addition to blood, many types of body fluids contain glucose. Continuous glucose monitoring (CGM) technology was first applied in clinical practice at the end of the twentieth century. It monitors the glucose concentrations in subcutaneous interstitial fluid through a glucose sensor and is able to provide continuous, comprehensive, and reliable all-day glucose profiles, thereby allowing for an understanding of the trends in blood glucose fluctuations, and to detect occult hyperglycemia and hypoglycemia that cannot be detected by traditional glucose monitoring methods. The detection equipment for measuring interstitial fluid glucose concentrations is mainly divided into two categories. One is minimally invasive technology in which interstitial glucose concentrations are continuously monitored with a subcutaneous glucose sensor, also known as the CGM system, which can be categorized as a retrospective CGM system or a real-time CGM system. The other is noninvasive technology, in which glucose is extracted across the skin for monitoring of glycemia using weak current electrodes close against the skin. This chapter will introduce the metabolism and regulation of glucose in the body, the detection of the interstitial glucose concentration and its clinical significance, as well as the principle of CGM technology.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   99.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   129.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   179.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Chinese Diabetes Society. Clinical application guide of blood glucose monitoring in China (Edition 2015). Chin J Diabetes. 2015;7:603–13. https://doi.org/10.3760/cma.j.issn.1674-5809.2015.10.004.

    Article  Google Scholar 

  2. Jansson PA, Fowelin J, Smith U, Lonnroth P. Characterization by microdialysis of intracellular glucose level in subcutaneous tissue in humans. Am J Phys. 1988;255:E218–20.

    CAS  Google Scholar 

  3. Dye L, Mansfield M, Lasikiewicz N, Mahawish L, Schnell R, Talbot D, Chauhan H, Croden F, Lawton C. Correspondence of continuous interstitial glucose measurement against arterialised and capillary glucose following an oral glucose tolerance test in healthy volunteers. Br J Nutr. 2010;103:134–40. https://doi.org/10.1017/S0007114509991504.

    Article  PubMed  CAS  Google Scholar 

  4. Boyne MS, Silver DM, Kaplan J, Saudek CD. Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes. 2003;52:2790–4.

    Article  CAS  PubMed  Google Scholar 

  5. Cengiz E, Tamborlane WV. A tale of two compartments: interstitial versus blood glucose monitoring. Diabetes Technol Ther. 2009;11(Suppl 1):11–6. https://doi.org/10.1089/dia.2009.0002.

    Article  Google Scholar 

  6. Sternberg F, Meyerhoff C, Mennel FJ, Mayer H, Bischof F, Pfeiffer EF. Does fall in tissue glucose precede fall in blood glucose? Diabetologia. 1996;39:609–12.

    Article  CAS  PubMed  Google Scholar 

  7. Zhou J, Jia WP, Yu M, Yu HY, Bao YQ, Ma XJ, Lu W, Hu C, Xiang KS. The reference values of glycemic parameters for continuous glucose monitoring and its clinical application. Zhong hua Nei Ke Za Zhi. 2007;46:189–92.

    CAS  Google Scholar 

  8. Zhou J, Li H, Ran X, Yang W, Li Q, Peng Y, Li Y, Gao X, Luan X, Wang W, Jia W. Reference values for continuous glucose monitoring in Chinese subjects. Diabetes Care. 2009;32:1188–93. https://doi.org/10.2337/dc09-0076.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Kilpatrick ES, Rigby AS, Goode K, Atkin SL. Relating mean blood glucose and glucose variability to the risk of multiple episodes of hypoglycemia in type 1 diabetes. Diabetologia. 2007;50:2553–61. https://doi.org/10.1007/s00125-007-0820-z.

    Article  PubMed  CAS  Google Scholar 

  10. Ji L, Guo X, Guo L, Ren Q, Yu N, Zhang J. A multicenter evaluation of the performance and usability of a novel glucose monitoring system in chinese adults with diabetes. J Diabetes Sci Technol. 2017;11:290–5. https://doi.org/10.1177/1932296816662884.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  11. Chase HP, Beck R, Tamborlane W, Buckingham B, Mauras N, Tsalikian E, Wysocki T, Weinzimer S, Kollman C, Ruedy K, Xing D. A randomized multicenter trial comparing the GlucoWatch biographer with standard glucose monitoring in children with type 1 diabetes. Diabetes Care. 2005;28:1101–6.

    Article  PubMed  Google Scholar 

  12. Zhou J, Lv X, Mu Y, Wang X, Li J, Zhang X, Wu J, Bao Y, Jia W. The accuracy and efficacy of real-time continuous glucose monitoring sensor in Chinese diabetes patients: a multicenter study. Diabetes Technol Ther. 2012;14:710–8. https://doi.org/10.1089/dia.2012.0014.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  13. Diabetes Research in Children Network (DirecNet) Study Group. Accuracy of the GlucoWatch G2 biographer and the continuous glucose monitoring system during hypoglycemia: experience of the diabetes research in children network. Diabetes Care. 2004;27:722–6.

    Article  Google Scholar 

  14. Corrie SR, Coffey JW, Islam J, Markey KA, Kendall MA. Blood, sweat, and tears: developing clinically relevant protein biosensors for integrated body fluid analysis. Analyst. 2015;140:4350–64. https://doi.org/10.1039/c5an00464k.

    Article  PubMed  CAS  Google Scholar 

  15. Ma X, Hu X, Zhou J, Hao Y, Luo Y, Lu Z, Bao Y, Jia W. Glycated albumin is more closely correlated with coronary artery disease than 1,5-anhydroglucitol and glycated hemoglobin A1c. Cardiovasc Diabetol. 2015;14:16. https://doi.org/10.1186/s12933-014-0166-z.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  16. Vigersky RA. Glucose monitoring. In: Umpierrez GE, editor. Therapy for diabetes mellitus and related disorders. 6th ed. Alexandria: American Diabetes Association; 2014. p. 28–50.

    Google Scholar 

  17. Bennion N, Christensen NK, McGarraugh G. Alternate site glucose testing: a crossover design. Diabetes Technol Ther. 2002;4:25–33.

    Article  CAS  PubMed  Google Scholar 

  18. Knapp PE, Showers KM, Phipps JC, Speckman JL, Sternthal E, Freund KM, Ash AS, Apovian CM. Self-monitoring of blood glucose with finger tip versus alternative site sampling: effect on glycemic control in insulin-using patients with type 2 diabetes. Diabetes Technol Ther. 2009;11:219–25.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  19. Suzuki Y, Atsumi Y, Matusoka K. Alternative site testing increases compliance of SMBG (preliminary study of 3 years cohort trials). Diabetes Res Clin Pract. 2003;59:233–4.

    Article  PubMed  Google Scholar 

  20. Bina DM, Anderson RL, Johnson ML, Bergenstal RM, Kendall DM. Clinical impact of prandial state, exercise, and site preparation on the equivalence of alternative-site blood glucose testing. Diabetes Care. 2003;26:981–5.

    Article  PubMed  Google Scholar 

  21. Jungheim K, Koschinsky T. Glucose monitoring at the arm: risky delays of hypoglycemia and hyperglycemia detection. Diabetes Care. 2002;25:956–60.

    Article  PubMed  Google Scholar 

  22. Tonyushkina K, Nichols JH. Glucose meters: a review of technical challenges to obtaining accurate results. J Diabetes Sci Technol. 2009;3:971–80. https://doi.org/10.1177/193229680900300446.

    Article  PubMed  PubMed Central  Google Scholar 

  23. Tang Z, Lee JH, Louie RF, Kost GJ. Effects of different hematocrit levels on glucose measurements with handheld meters for point-of-care testing. Arch Pathol Lab Med. 2000;124:1135–40. https://doi.org/10.1043/0003-9985(2000)124<1135:EODHLO>2.0.CO;2.

    Article  PubMed  CAS  Google Scholar 

  24. Ginsberg BH. Factors affecting blood glucose monitoring: sources of errors in measurement. J Diabetes Sci Technol. 2009;3:903–13. https://doi.org/10.1177/193229680900300438.

    Article  PubMed  PubMed Central  Google Scholar 

  25. Belazi MA, Galli TA, Drakoulakos D, Fleva A, Papanayiotou PH. Salivary alterations in insulin-dependent diabetes mellitus. Int J Paediatr Dent. 1998;8:29–33.

    Article  CAS  PubMed  Google Scholar 

  26. March WF, Mueller A, Herbrechtsmeier P. Clinical trial of a noninvasive contact lens glucose sensor. Diabetes Technol Ther. 2004;6:782–9. https://doi.org/10.1089/dia.2004.6.782.

    Article  PubMed  CAS  Google Scholar 

  27. Badugu R, Lakowicz JR, Geddes CD. A glucose-sensing contact lens: from bench top to patient. Curr Opin Biotechnol. 2005;16:100–7. https://doi.org/10.1016/j.copbio.2004.12.007.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  28. Su H, Ma X, Yin J, Wang Y, He X, Bao Y, Zhou J, Jia W. Serum 1,5-anhydroglucitol levels slightly increase rather than decrease after a glucose load in subjects with different glucose tolerance status. Acta Diabetol. 2017;54:463–70. https://doi.org/10.1007/s00592-017-0968-z.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to W. Jia .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd. and Shanghai Scientific and Technical Publishers

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Wang, Y.F., Jia, W. (2018). Determination of Glucose and Continuous Glucose Monitoring. In: Jia, W. (eds) Continuous Glucose Monitoring. Springer, Singapore. https://doi.org/10.1007/978-981-10-7074-7_1

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-7074-7_1

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-7073-0

  • Online ISBN: 978-981-10-7074-7

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics