Abstract
The introduction of computer-assisted surgery is an important landmark in the history of orthopedics. Its clinical use for total hip arthroplasty is recent. It can be image-based or imageless depending on the registration technique used: whether imageless or based on preoperative/intraoperative radiological images. It has changed the way surgeons perceive procedures. In this chapter, we describe an imageless method of computer navigation. It guides the surgeon through the various surgical steps that the surgeon could only speculate about previously. With this system, the surgeon sees the operation on a monitor in real time. It helps not only with acetabular orientation; it shows the cup’s center shift at the time of reaming and cup insertion. Similarly, it can show femoral stem orientation and the changes it will make in leg length and its offset, thereby helping with final selection of the prosthesis. Its accuracy and precision have been reported by many to be >95% regarding cup orientation, offset, and leg-length reproducibility. There is, however, a learning curve. The initial cases take more time to complete, but with experience, the operating time is lengthened by only 5–10 min. The instrumentation and technique could (and no doubt will) be improved. Even now, however, it has allowed more accurate and reproducible surgery. The preoperative plan can be executed with unprecedented accuracy compared with that achieved using conventional techniques.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Wixson RL. Computer-assisted total hip navigation. Instr Course Lect. 2008;57:707–20.
Ecker TM, Murphy SB. Application of surgical navigation to total hip arthroplasty. Proc Inst Mech Eng H. 2007;221(7):699–712.
Sugano N, Nishii T, Miki H, Yoshikawa H, Sato Y, Tamura S. Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation. J Bone Joint Surg Br. 2007;89(4):455–60.
Murali R, Bonar SF, Kirsh G, Walter WK, Walter WL. Osteolysis in third-generation alumina ceramic-on-ceramic hip bearings with severe impingement and titanium metallosis. J Arthroplasty. 2008;23(8):1240.e13–9.
Onda K, Nagoya S, Kaya M, Yamashita T. Cup-neck impingement due to the malposition of the implant as a possible mechanism for metallosis in metal-on-metal total hip arthroplasty. Orthopaedics. 2008;31(4):396.
Langton DJ, Joyce TJ, Jameson SS, et al. Adverse reaction to metal debris following hp resurfacing – the influence of component type, orientation and volumetric wear. J Bone Joint Surg Br. 2011;93B(2):164–71.
Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60(2):217–20.
Hakki S, Bilotta V, Oliveira D, Dordelly L. Acetabular central axis; Is it the future of hp navigation? Orthopaedics. 2010;33(10 Suppl):43–7.
Pinoit Y, May O, Girard J, Laffargue P, Ala Eddine T, Migaud H. Low accuracy of anterior pelvic plane to guide the position of the cup with imageless computer assistance. Variation of position in 106 patients. Rev Chir Orthop Reparatrice Appar Mot. 2007;93(5):455–60.
Deep K, Ward N, Donnelly W, Tevelan G, Crawford R. Biomechanical force displacement analysis of strength of fixation of tracker holding devices to bone in computer aided joint replacements. J Bone Joint Surg Br. 2006;88B(Supp):439.
Barrack R. Dislocation after total hip arthroplasty: implant design and orientation. J Am Acad Orthop Surg. 2003;11:89.
McCollum DE, Gray WJ. Dislocations after total hip arthroplasty: causes and prevention. Clin Orthop. 1990;261:159.
Di Gioia AM, Jaramaz B, Blackwell M, et al. The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res. 1998;355:8–22.
Kalteis T, Handel M, Herold T, et al. Greater accuracy in positioning of the acetabular cup by using an image-free navigation system. Int Orthop. 2005;29(5):272–6.
Najarian BC, Kilgore JE, Markel DC. Evaluation of component positioning in primary total hip arthroplasty using an imageless navigation device compared with traditional methods. J Arthroplasty. 2009;24(1):15–21.
Saxler G, Marx A, Vandevelde D, et al. The accuracy of free-hand cup positioning: a CT based measurement of cup placement in 105 total hip arthroplasties. Int Orthop. 2004;28:198–201.
Hassan DM, Johnston GH, Dust WN, Watson G, Dolovich AT. Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty. 1998;13(1):80–4.
Callanan MC, Jarrett B, Bragdon CR, Zurakowski D, Rubash HE, Frieberg AA, Malchau H. Risk factors for cup malpositioning: quality improvement through a joint registry in a tertiary hospital. Clin Orthop Relat Res. 2011;469(2):319–29.
Deep K, Khan MS, Deakin A. Assessment of precision and accuracy of computer navigation in total hip Arthroplasty. Bone Joint J. 2013;95-B(Suppl 28):47.
Lecerf G, et al. Femoral offset: anatomical concept, definition, assessment, implications of preoperative templating and hip arthroplasty. Orthop Traumatol Surg Res. 2009;95:210–9.
Sakalkale DP, Sharkey PF, Eng K, et al. Effect of femoral component offset on polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 2011;388:125.
Little NJ, Busch CA, Gallagher JA, Rorabeck CH, Bourne RB. Acetabular polyethylene wear and acetabular inclination and femoral offset. Clin Orthop Relat Res. 2009;467:2895–900.
Maloney WJ, Keeney JA. Leg length discrepancy after total hip arthroplasty. J Arthroplasty. 2004;19(Suppl 1):108.
Konyves A, Bannister GC. The importance of leg length discrepancy after total hip replacement. J Bone Joint Surg. 2005;87B(2):155–7.
Dolhain P, et al. The effectiveness of dual offset stems in restoring offset during total hip replacement. Acta Orthop Belg. 2002;68:490–9.
Dastane M, Dorr LD, Tarwala R, Wan Z. Hip offset in total hip arthroplasty: quantitative measurement with navigation. Clin Orthop Relat Res. 2011;469:429–36.
Ellapparadja P, Mahajan V, Deakin AH, Deep K. Reproduction of hip offset and leg length in navigated total hip arthroplasty: how accurate are we? J Arthroplasty. 2015;30(6):1002–7.
Confalonieri N, Manzotti A, Montironi F, Pullen C. Leg length discrepancy, dislocation rate, and offset in total hip replacement using a short modular stem: navigation vs conventional freehand. Orthopaedics. 2008;31(10 Suppl 1)
Ellapparadja P, Mahajan V, Atiya S, Sankar B, Deep K. Leg length discrepancy in computer navigated total hip arthroplasty - how accurate are we? Hip Int. 2016;26(5):438–43.
Gofton W, Dubrowski A, Tabloie F, Backstein D. The effect of computer navigation on trainee learning of surgical skills. J Bone Joint Surg Am. 2007;89(12):2819–27.
Deep K, Picard F. Computer assisted navigation in primary total hip arthroplasty. Orthopaedics Trauma. 2014;28(5):309–14.
Picard F, Deep K. Role of Computer assisted surgery in training and outcomes. Orthopaedics Trauma. 2014;28(5):322–6.
Judet H. Five years of experience in hip navigation using a mini-invasive anterior approach. Orthopaedics. 2007;30(10 Suppl):S141–3.
Conflict of Interest
The author’s department has received research funding from several companies (nonexhaustive list): Zimmer; Stryker, BBraun, Mathys, Convatec, Blue Belt Technology. The author has received consulting fees from BBraun Aesculap.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer Nature Singapore Pte Ltd.
About this chapter
Cite this chapter
Deep, K. (2018). Imageless Computer-Assisted Navigation for Total Hip Arthroplasty. In: Sugano, N. (eds) Computer Assisted Orthopaedic Surgery for Hip and Knee. Springer, Singapore. https://doi.org/10.1007/978-981-10-5245-3_9
Download citation
DOI: https://doi.org/10.1007/978-981-10-5245-3_9
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-5244-6
Online ISBN: 978-981-10-5245-3
eBook Packages: MedicineMedicine (R0)