Abstract
The rupture of atherosclerotic plaques is the leading cause of acute coronary events. The detection of lipid content and its distribution within the plaques is critical for identifying vulnerable plaques that are prone to rupture [1]. Intravascular spectroscopic photoacoustic technology is capable of imaging the composition and structure of atherosclerotic plaques [2, 3]. To achieve accurate spectroscopic IVPA imaging, an ns-pulsed, wavelength tunable laser [e.g., optical parameter oscillator (OPO) laser] is critical. However, in previously reported IVPA systems, laser pulse energy in the order of mJ was usually required to produce decent photoacoustic signals, so the choices of laser sources were usually limited to OPO lasers of a pulse repetition rate of 10–20 Hz. The B-scan rate at a single wavelength with such lasers was 0.05–0.1 f/s (assuming 200 A-lines/B-scan); for spectroscopic imaging, the image acquisition would take several times longer. Overall, the imaging speed is becoming one of the major challenges for translating IVPA into clinical applications [4, 5]. In this study, a catheter of 0.9 mm in diameter with a novel quasi-focusing light illumination scheme is designed and developed, smaller than the critical size of 1 mm required for clinical translation. With this design, the laser fluence in the targeted imaging region was increased, which produced detectable signals with laser energy as low as ~30 μJ/pulse. As a result, a 1-kHz-repetition-rate, ns-pulsed optical parametric oscillator (OPO) laser was able to be utilized to achieve high-speed IVPA imaging, working at both the 1.2 and 1.7 μm spectral bands for lipid detection. Specifically, a B-scan acquisition rate of 5 Hz was achieved, ~100-fold faster than conventional IVPA systems operating at the similar tunable range. With the system, multi-wavelength (five wavelengths) spectroscopic IVPA imaging of both a lipid-mimicking phantom and peri-adventitial adipose tissue from a porcine vessel was demonstrated at both the 1.2 and 1.7 μm spectral bands. The significantly improved imaging speed, together with the reduced catheter size and multi-wavelength spectroscopic imaging ability, suggests that the developed high-speed IVPA technology is of great potential to be further translated for in vivo applications.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
E. Falk, P. K. Shah, and V. Fuster, “Coronary Plaque Disruption,” Circulation, vol. 92, no. 3, pp. 657–671, 1995.
L. H. V. Wang and S. Hu, “Photoacoustic Tomography: In Vivo Imaging from Organelles to Organs,” Science, vol. 335, no. 6075, pp. 1458–1462, 2012.
K. Jansen, M. Wu, A. F. W. van der Steen, and G. van Soest, “Lipid detection in atherosclerotic human coronaries by spectroscopic intravascular photoacoustic imaging,” Opt Express, vol. 21, no. 18, pp. 21472–21484, 2013.
L. Song, K. Maslov, and L. H. V. Wang, “Multifocal optical-resolution photoacoustic microscopy in vivo,” Opt Lett, vol. 36, no. 7, pp. 1236–1238, 2011.
X. S. Bai, X. J. Gong, W. Hau, R. Q. Lin, J. X. Zheng, C. B. Liu, C. Z. Zeng, X. Zou, H. R. Zheng, and L. Song, “Intravascular Optical-Resolution Photoacoustic Tomography with a 1.1 mm Diameter Catheter,” Plos One, vol. 9, no. 3, p. 0092463, 2014.
Acknowledgements
This work was supported in part by the National Natural Science Foundation of China under Grant Nos. 81427804, 61205203, 61405234, and 61475182; the National Key Basic Research (973) Program of China under Grant Nos. 2014CB744503 and 2015CB755500; the Shenzhen Science and Technology Innovation under Grant Nos. ZDSY- 2013-0401165820-357, KQCX-2012-0816155844-962, CXZZ-2012-0617113635-699, and JCYJ-2012-0615125857-842; Gungdong Innovation Research Team Fund for Low-cost Healthcare Technologies (GIRIF-LCHT).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Gong, X., Li, Y., Lin, R., Leng, J., Song, L. (2019). High-Speed Intravascular Spectroscopic Photoacoustic Imaging at Two Spectral Bands. In: Zhang, YT., Carvalho, P., Magjarevic, R. (eds) International Conference on Biomedical and Health Informatics. ICBHI 2015. IFMBE Proceedings, vol 64. Springer, Singapore. https://doi.org/10.1007/978-981-10-4505-9_33
Download citation
DOI: https://doi.org/10.1007/978-981-10-4505-9_33
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-4504-2
Online ISBN: 978-981-10-4505-9
eBook Packages: EngineeringEngineering (R0)