Models of a WTGS Operating in a Power System

  • Chapter
Wind Turbine Operation in Electric Power Systems

Part of the book series: Power Systems ((POWSYS))

Abstract

The chapter presents models of various types of WTGS, whose components were considered in the previous chapters. In this chapter the following types of wind turbine models are considered:

  • • WTGS equipped with squirrel-cage rotor asynchronous generator

  • • WTGS equipped with dynamic slip control system

  • • WTGS equipped with doubly-fed asynchronous machine

  • • WTGS equipped with synchronous generator (two types of converter are considered).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Reference

  1. This is, of course, a simplification because in practice the factor for Hv transmission lines is lower than for MV lines. Additionally, the HV transmission line capacitance is higher than the MV line capacitance.

    Google Scholar 

  2. Of course, the supervisory control system does exist in the case of the WTGS.

    Google Scholar 

  3. Data for the delta and star winding connection of asynchronous generator.

    Google Scholar 

  4. Italic typeface indicates assumed data.

    Google Scholar 

  5. All the controllers considered in this and the following section are PI-type controllers with parameters Kr, Ti. The utilization of controllers of this type are given as examples only and does not mean that these types of controller are or should be used in real WTGSs. The controller parameters are given in the figure captions. The parameters should not be treated as optimal either.

    Google Scholar 

  6. For modeling purposes, the Enron EW 900 wind turbine data have been utilized here. This WTGS was originally a system equipped with a doubly-fed asynchronous generator (considered in the next section). For the considerations conducted here, the use of this wind turbine.

    Google Scholar 

  7. Italic typeface indicates assumed data.

    Google Scholar 

  8. The change of the operating point depends on the power versus wind velocity P=-f(V) and motor mechanical t=f(w) characteristics.

    Google Scholar 

  9. This is in contrast to the previously and further considered WTGS with turbine speed contronller and generator power controller operating at full load.

    Google Scholar 

  10. Voltages Vdr,Vqr are recalculated on the stator side.

    Google Scholar 

  11. The real power transferred to the grid is equal to the sum of the stator and rotor power, I.e. Pg=Pgs+Pgr. The reactive power is equal to the difference of the stator power and the reactive power losses in a grid-side of converter and transformer.

    Google Scholar 

  12. The data in Italic typeface indicate assumed data.

    Google Scholar 

  13. The first state takes place at wind velocity slightly below 10 m/s, the second one at a wind velocity equal to 12 m/s.

    Google Scholar 

  14. This remark is related to the WTGS operation at full load. At partial load, elimination of real power variation is impossible for other reasons considered in this monograph.

    Google Scholar 

  15. The conclusions related to the results of the simulations presented in this chapter do not have general validity and cannot be considered as valid for the all wind turbines equipped with a given type of control system. The control system structures, algorithms, parameters and strategies in various types of WTGSs vary considerably.

    Google Scholar 

  16. The values printed in the Table and related to the WTGS equipped with a synchronous generator (Pn=500KW) are multiplied by factor 900/500 to allow comparison with other WTGSs(Pn=900kw).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 2003 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Lubosny, Z. (2003). Models of a WTGS Operating in a Power System. In: Wind Turbine Operation in Electric Power Systems. Power Systems. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-10944-1_6

Download citation

  • DOI: https://doi.org/10.1007/978-3-662-10944-1_6

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-07317-5

  • Online ISBN: 978-3-662-10944-1

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics