Summary
After disinfection and sterilisation, the cleaning of instruments has been shifted to the foreground. The section for MIS in Tübingen has developed a method for reliable validation of cleaning which is decisive for sterilisability. It was proved with the aid of radioactively marked macroalbumins that endoscopic instruments become partly filled and can only be cleaned reliably by a defined rinsing process. A validated cleaning is possible with take-apart instruments (with the new instrument generation). Rinsing with the aid of a Luerlock insert requires very high pressures and long rinsing times (newly developed cleaning devices of Netsch). The study group Hygienics in Tübingen recommends the use of take-apart and rinsable instruments only. Other instruments cannot be sterilised reliably because they cannot be cleaned reliably. Disposable instruments must be used once only as they cannot be cleaned for a re-sterilisation.
Zusammenfassung
Nach Desinfektion und Sterilisation steht nun die Frage der Reinigung von Instrumenten im Vordergrund. Die Sektion für MIC in Tübingen hat eine zuverlässige Validierung der Reinigung entwickelt, was entscheidend für die Sterilisierbar-keit ist. Durch radioaktiv markierte Makroalbumine wurde nachgewiesen, daß sich endoskopische Instrumente teilweise füllen und nur durch einen definierten Spülprozeß zuverlässig zu reinigen sind. Eine validierte Reinigung ist bei zerlegbaren Instrumenten möglich (neue Instrumentengeneration). Die Spülung mit Luerlock-Einsatz benötigt sehr hohe Drücke und lange Spülzeiten (neuentwickelte Reinigungsgeräte von Netsch). Der AK Hygiene in Tübingen empfiehlt, nur noch zerlegbare und spülbare Instrumente zu verwenden. Andere sind nicht zuverlässig sterilisierbar, weil nicht kontrolliert reinigbar. Einmalinstrumente dürfen deshalb nur einmal verwendet werden, da sie nicht für eine ReSterilisation gereinigt werden können.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsAuthor information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1996 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Bueß, G., Roth, K. (1996). Die Bedeutung von Desinfektion und Sterilisation bei Einweg- und Mehrweginstrumenten. In: Hartel, W. (eds) Wahrung des Bestandes, Wandel und Fortschritt der Chirurgie. Langenbecks Archiv für Chirurgie, vol 1996. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-80295-9_195
Download citation
DOI: https://doi.org/10.1007/978-3-642-80295-9_195
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-61617-7
Online ISBN: 978-3-642-80295-9
eBook Packages: Springer Book Archive