Skip to main content

Entwicklung eines Rotationskatheters zur dynamischen Angioplastie

Development of a Milling Catheter for Dynamic Angioplasty

  • Conference paper
Book cover Verhandlungen der Deutschen Gesellschaft für Chirurgie

Part of the book series: Langenbecks Archiv für Chirurgie ((KONGRESSBAND,volume 1988))

  • 4 Accesses

Summary

We developed three milling catheters (2.3, 3.0 and 3.5 mm Ø) consisting of a rotating head that is connected to a high-speed driving motor (frequency up to 80,000 rpm) via a flexible cable. The rinse fluid from numerous holes within the head has cooling as well as antithrombotic properties. The catheters were employed percutaneously (2.3 mm) and in conjunction with vascular surgery to treat occlusions of the superficial femoral and the popliteal artery when impassable to a guide wire. The dynamic recanalisation was successful in eight patients with severe ischemia. Two patients underwent a femoropopliteal bypass. The special construction of this device reduces the risk of perforation or emoblisation.

Zusammenfassung

Wir entwickelten 3 Fräskatheter (2,3 3,0 u. 3,5 mm 0), die aus einem rotierenden Kopf bestehen, der mit einem regelbaren Elektromotor (Frequenz bis 80 000/min) über ein flexibles Kabel verbunden ist. Die Spülflüssigkeit tritt aus zahlreichen Öffnungen an der Spitze aus und hat zugleich kühlende als auch antithrombotische Eigenschaften. Die Katheter wurden perkutan (2,3 mm) und in Verbindung mit einem gefäßchirurgischen Eingriff benutzt zur Behandlung von Verschlüssen der A. femoralis superficialis, die mit dem Führungsdraht nicht passierbar waren. Bei 8 Patienten war die Rekanalisation erfolgreich; 2 Patienten erhielten einen femoro-poplitealen Bypass. Dieses spezielle System ist so konstruiert, daß eine minimale Perforations- und Embolisationsgefahr besteht.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 49.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 59.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 1988 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Steckmeier, B., Baumgart, R. (1988). Entwicklung eines Rotationskatheters zur dynamischen Angioplastie. In: Verhandlungen der Deutschen Gesellschaft für Chirurgie. Langenbecks Archiv für Chirurgie, vol 1988. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-48161-1_243

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-48161-1_243

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-50433-7

  • Online ISBN: 978-3-642-48161-1

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics