Balloons are used on a daily basis in the paediatric and congenital heart catheterization laboratory. A wide range of balloons is currently available. Most balloons are used for static dilation of a cardiac or vascular structure. The properties of those balloons vary, and the differences have to be known and understood by the interventionalist in order to make the best use of them. Pressure characteristics are of major clinical importance. Low-pressure, medium-pressure, high-pressure and ultra-high-pressure balloon catheters exist and have different clinical applications. The cutting balloon, the BIB® catheter and the dumbbell-shaped balloons may be very useful for dilation in specific circumstances. Balloon catheters may be used for atrial septostomy and for sizing of heart defects. Balloon catheters need careful preparation, introduction and inflation. Complications may occur and need to be correctly recognized and managed.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   189.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD   249.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Abele JE. Balloon catheters and transluminal dilatation: technical considerations. Am J Roentgenol. 1980;135:901–6.

    Article  CAS  Google Scholar 

  2. Lock JE, Keane JF, Perry SB, editors. Diagnostic and interventional catheterization in congenital heart disease. 2nd ed. Boston, MA: Kluwer Academic Publishers; 2000.

    Google Scholar 

  3. Mullins C. Balloon dilation procedures—general. In: Mullins C, editor. Cardiac catheterization in congenital heart disease: pediatric and adult. Masachusetts: Blackwell Futura; 2006. p. 410–29.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

1 Electronic Supplementary Material

Preparation of balloons. Step 1: Fill 1 syringe and an indeflator with diluted contrast. The recommended ratio is 1 unit of contrast and 3–4 units of saline, but this may vary according to the type of balloon used, the purpose and operator’s habits. The size of the syringe depends on the size of the balloon. A second syringe can replace the indeflator, if the indeflator is not needed (low pressure balloons). Step 2: Connect the indeflator and syringe to a three-way stopcock. Deair the whole system (syringe, indeflator and stopcock) before connecting to the balloon. Step 3: Deair the balloon. This can be done in different ways. The balloon can be gently inflated at no pressure which will allow subsequent removal of the air bubbles. However, this technique has the disadvantage of unfolding the balloon, which will then loose its ‘profile’. Refolding the balloon is sometimes possible but time-consuming. The usual way of deairing is the ‘negative prep’ technique: a strong negative pressure is applied to the balloon with the indeflator or with the syringe, and this negative pressure is maintained by blocking the indeflator or syringe [3]. The three-way stopcock is then turned to connect the balloon with the other syringe which will then allow the balloon catheter to passively fill with the contrast. This manoeuvre is repeated a few times to allow full replacement of air by contrast. At the end, negative pressure is again applied to the balloon before entering the balloon catheter into the sheath. Step 4: Flush the wire lumen of the balloon catheter (M4V 16073 kb)

Balloon inflation and deflation with indeflator. When using an indeflator for balloon dilation, two steps have to be distinguished. During the first step, the indeflator needs to be in the ‘open’ position. Pushing gently on the piston pushes the diluted contrast into the balloon at low pressure. Once the balloon has reached the full diameter, leaving only the waist at smaller diameter, the indeflator has to be switched to the ‘closed’ position. The piston of the indeflator then needs to be screwed to increase the pressure gradually. Once the waist has disappeared, the indeflator has to be switched again to the ‘open’ position to release the pressure and withdraw the diluted contrast (M4V 21664 kb)

Burst of balloon. This video shows the longitudinal tear of a Tyshak II® 25 mm balloon used to try to replace and dilate unstable stents placed in a very dilated pulmonary valve, before percutaneous valve insertion. The contrast suddenly disappears into the pulmonary arteries which signs the rupture of the balloon (AVI 100773 kb)

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer International Publishing AG, part of Springer Nature

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Ovaert, C., Martins, D. (2019). Balloons. In: Butera, G., Chessa, M., Eicken, A., Thomson, J.D. (eds) Atlas of Cardiac Catheterization for Congenital Heart Disease. Springer, Cham. https://doi.org/10.1007/978-3-319-72443-0_3

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-72443-0_3

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-72442-3

  • Online ISBN: 978-3-319-72443-0

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics