Skip to main content

Percutaneous Pedicle Screw/Rod Fixation

  • Chapter
  • First Online:
Minimally Invasive Spine Surgery Techniques

Abstract

Percutaneous instrumented posterior fixation with pedicle screws and rods is frequently used. The insertion of the percutaneous pedicle screws is identical among the various platforms, whereas insertion of the rod can be done in three different ways, depending on the system utilized. The target entry point is at the junction of the lateral facet and the transverse process (or ala, for S1). We prefer to use beveled Jamshidi needles, since they provide better directional insertion.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 119.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 159.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 159.00
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Ahmad FU, Wang MY. Use of anteroposterior view fluoroscopy for targeting percutaneous pedicle screws in cases of spinal deformity with axial rotation. J Neurosurg Spine. 2014;21:826–32. https://doi.org/10.3171/2014.7.spine13846.

    Article  PubMed  Google Scholar 

  2. Ikeuchi H, Ikuta K. Accuracy of pedicle screw insertion in the thoracic and lumbar spine: a comparative study between percutaneous screw insertion and conventional open technique. Arch Orthop Trauma Surg. 2016;136:1195–202. https://doi.org/10.1007/s00402-016-2502-0.

    Article  PubMed  Google Scholar 

  3. Oh HS, Kim JS, Lee SH, Liu WC, Hong SW. Comparison between the accuracy of percutaneous and open pedicle screw fixations in lumbosacral fusion. Spine J. 2013;13:1751–7. https://doi.org/10.1016/j.spinee.2013.03.042.

    Article  PubMed  Google Scholar 

  4. Chiu CK, Kwan MK, Chan CY, Schaefer C, Hansen-Algenstaedt N. The accuracy and safety of fluoroscopically guided percutaneous pedicle screws in the lumbosacral junction and the lumbar spine: a review of 880 screws. Bone Joint J. 2015;97-B:1111–7. https://doi.org/10.1302/0301-620x.97b8.35330.

    Article  CAS  PubMed  Google Scholar 

  5. Nimjee SM, et al. Safe and accurate placement of thoracic and thoracolumbar percutaneous pedicle screws without image-navigation. Asian J Neurosurg. 2015;10:272–5. https://doi.org/10.4103/1793-5482.162700.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Smith ZA, Sugimoto K, Lawton CD, Fessler RG. Incidence of lumbar spine pedicle breach after percutaneous screw fixation: a radiographic evaluation of 601 screws in 151 patients. J Spinal Disord Tech. 2014;27:358–63. https://doi.org/10.1097/BSD.0b013e31826226cb.

    Article  PubMed  Google Scholar 

  7. Hansen-Algenstaedt N, et al. Accuracy and safety of fluoroscopic guided percutaneous pedicle screws in thoracic and lumbosacral spine: a review of 2000 screws. Spine. 2015;40:E954–63. https://doi.org/10.1097/brs.0000000000000958.

    Article  PubMed  Google Scholar 

  8. Wang L, Wang Y, Yu B, Li Z, Li Y. Comparison of cranial facet joint violation rate between percutaneous and open pedicle screw placement: a systematic review and meta-analysis. Medicine. 2015;94:e504. https://doi.org/10.1097/md.0000000000000504.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Yson SC, et al. Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement using intraoperative 3-D CT (O-arm) computer navigation. Spine. 2013;38:E251–8. https://doi.org/10.1097/BRS.0b013e31827ecbf1.

    Article  PubMed  Google Scholar 

  10. Babu R, et al. Comparison of superior-level facet joint violations during open and percutaneous pedicle screw placement. Neurosurgery. 2012;71:962–70. https://doi.org/10.1227/NEU.0b013e31826a88c8.

    Article  PubMed  PubMed Central  Google Scholar 

  11. Park Y, Ha JW, Lee YT, Sung NY. Cranial facet joint violations by percutaneously placed pedicle screws adjacent to a minimally invasive lumbar spinal fusion. Spine J. 2011;11:295–302. https://doi.org/10.1016/j.spinee.2011.02.007.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Electronic Supplementary Material Percutaneous pedicle screw electronic supplementary material

Percutaneous pedicle screw insertion using the AP technique on the contralateral side of an MI TLIF (MP4 18484 kb)

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer International Publishing AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Serban, D., Calina, N., DiGiorgio, A., Lasseigne, L., Tender, G. (2018). Percutaneous Pedicle Screw/Rod Fixation. In: Tender, G. (eds) Minimally Invasive Spine Surgery Techniques. Springer, Cham. https://doi.org/10.1007/978-3-319-71943-6_9

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-71943-6_9

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-71942-9

  • Online ISBN: 978-3-319-71943-6

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics