Abstract
Continuous intraoperative nerve monitoring (CIONM) is an advanced tool to improve risk management of the recurrent laryngeal nerve (RLN) by ongoing determination of vagus amplitude and latency during thyroid surgery. The advantage of CIONM compared to intermittent nerve stimulation (IIONM) becomes apparent in technically demanding operations because CIONM provides instant alerts as soon as a surgical procedure impinges on the RLN. This is why CIONM is set to overcome the principal methodological limitation of IIONM, which is identification of RLN malfunction only after the damage has taken place.
Animal and human studies have consistently confirmed the feasibility, safety, and reliability of CIONM. By implication, accurate prediction of impending RLN injury hinges on the evaluation of wave changes which indicate nerve dysfunction that ultimately may result in complete loss of electromyographical (EMG) signal (LOS). “Combined events,” defined as concordant EMG changes in both amplitude (decreases to less than 50 % of initial baseline) and latency (increase to more than 110 % of initial baseline), typically precede postoperative vocal fold palsy and are reversible in 80 % of cases upon release of the nerve. CIONM also helps identifying functional nerve recovery with restitution of the amplitude to ≥50 % of its baseline so that surgical plans can be adjusted accordingly.
CIONM can prompt corrective actions before LOS occurs. Recent evidence suggests that CIONM may afford better nerve protection than IIONM, which resulted in permanent RLN palsy rates of 0 % with CIONM vs. 0.4 % with IIONM (P = 0.019).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Cernea CR, Brandão LG, Brandão J. Neuromonitoring in thyroid surgery. Curr Opin Otolaryngol Head Neck Surg. 2012;20:125–9.
Dralle H, Sekulla C, Lorenz K, Nguyen Thanh P, Schneider R, Machens A. Loss of the nerve monitoring signal during bilateral thyroid surgery. Br J Surg. 2012;99:1089–95.
Dralle H, Lorenz K, Schabram P, Musholt TJ, Dotzenrath C, Goretzki PE, et al. Surgical Working Group for Endocrinology [Intraoperative neuromonitoring in thyroid surgery. Recommendations of the Surgical Working Group for Endocrinology]. Chirurg. 2013;84:1049–56.
Lamadé W, Meyding-Lamade U, Hund E, Senninger N, Herfarth C. Transtracheal monitoring of the recurrent laryngeal nerve. Prototype of a new tube. Chirurg. 1997;68:193–5.
Lamadé W, Meyding-Lamade U, Buchhold C, Brauer M, Brandner R, Uttenweiler V, et al. First continuous nerve monitoring in thyroid gland surgery. Chirurg. 2000;71:551–7.
Lamadé W, Ulmer C, Seimer A, Molnar V, Meyding-Lamade U, Thon K, et al. A new system for continuous recurrent laryngeal nerve monitoring. Minim Invasive Ther Allied Technol. 2007;16:149–54.
Ulmer C, Koch K, Seimer A, Molnar V, Meyding-Lamade U, Thon K, et al. Real-time monitoring of the recurrent laryngeal nerve: an observational clinical trial. Surgery. 2008;143:359–65.
Schneider R, Randolph GW, Sekulla C, Phelan E, Thanh PN, Bucher M, et al. Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury. Head Neck. 2013;35:1591–98.
Schneider R, Przybyl J, Pliquett U, Hermann M, Wehner M, Pietsch UC, et al. A new vagal anchor electrode for real-time monitoring of the recurrent laryngeal nerve. Am J Surg. 2010;199:507–14.
Schneider R, Lamadé W, Hermann M, Goretzki P, Timmermann W, Hauss J, et al. [Continuous intraoperative neuromonitoring of the recurrent laryngeal nerve in thyroid surgery (CIONM)—where are we now?]. Zentralbl Chir. 2012;137:88–90.
Randolph G, Dralle H, International Intraoperative Monitoring Study Group. Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope. 2011;121 Suppl 1:S1–16.
Castoro M, Yoo P, Hincapie J, Hamann J, Ruble S, Wolf P, et al. Excitation properties of the right cervical vagus nerve in adult dogs. Exp Neurol. 2011;227:62–8.
Groves DA, Brown VJ. Vagal nerve stimulation: a review of its applications and potential mechanisms that mediate its clinical effects. Neurosci Biobehav Rev. 2005;29:493–500.
Ulmer C, Friedrich C, Kohler A, Rieber F, Basar T, Deuschle M, Thon K, Lamadé W. Impact of continuous intraoperative neuromonitoring on autonomic nervous system during thyroid surgery. Head Neck. 2011;33:976–84.
Yoo P, Lubock N, Hincapie J, Ruble S, Hamann J, Grill W. High-resolution measurement of electrically-evoked vagus nerve activity in the anesthetized dog. J Neural Eng. 2013;10:026003.
Wu C, Dionigi G, Chen H, Chen H, Lee K, Lu I, et al. Vagal nerve stimulation without dissecting the carotid sheath during intraoperative neuromonitoring of the recurrent laryngeal nerve in thyroid surgery. Head Neck. 2013;35:1443–7.
Lorenz K, Abuazab M, Sekulla C, Schneider R, Nguyen Thanh P, Dralle H. Results of intraoperative neuromonitoring in thyroid surgery and preoperative vocal cord paralysis. World J Surg. 2014;38:582–91.
Dralle H, Damm I, Scheumann GF, Kotzerke J, Kupsch E, Geerlings H, et al. Compartment-oriented microdissection of regional lymph nodes in medullary thyroid carcinoma. Surg Today. 1994;24:112–21.
Dionigi G, Chiang F, Rausei S, Wu C, Boni L, Lee K, et al. Surgical anatomy and neurophysiology of the vagus nerve (VN) for standardised intraoperative neuromonitoring (IONM) of the inferior laryngeal nerve (ILN) during thyroidectomy. Langenbecks Arch Surg. 2010;395:893–9.
Schneider R, Przybyl J, Hermann M, Hauss J, Jonas S, Leinung S. A new anchor electrode design for continuous neuromonitoring of the recurrent laryngeal nerve by vagal nerve stimulations. Langenbecks Arch Surg. 2009;394:903–10.
Friedrich C, Ulmer C, Rieber F, Kern E, Kohler A, Schymik K, et al. Safety analysis of vagal nerve stimulation for continuous nerve monitoring during thyroid surgery. Laryngoscope. 2012;122:1979–87.
Dionigi G, Chiang FY, Dralle H, Boni L, Rausei S, Rovera F, et al. Safety of neural monitoring in thyroid surgery. Int J Surg. 2013;11 Suppl 1:S120–6.
Phelan E, Schneider R, Lorenz K, Dralle H, Kamani D, Potenza A, et al. Continuous vagal IONM prevents RLN paralysis by revealing initial EMG changes of impending neuropraxic injury: a prospective, multicenter study. Laryngoscope. 2014;124:1498–505.
Schneider R, Sekulla C, Machens A, Lorenz K, Nguyen-Thanh P, Dralle H. Postoperative vocal fold palsy in patients undergoing thyroid surgery with continuous and intermittent nerve monitoring. Br J Surg. 2015;102(11):1380–7.
Van Slycke S, Gillardin JP, Brusselaers N, Vermeersch H. Initial experience with S-shaped electrode for continuous vagal nerve stimulation in thyroid surgery. Langenbecks Arch Surg. 2013;398:717–22.
Brauckhoff M, Machens A, Sekulla C, Lorenz K, Dralle H. Latencies shorter than 3.5 ms after vagus nerve stimulation signify a nonrecurrent inferior laryngeal nerve before dissection. Ann Surg. 2011;253:1172–7.
Ben-Menachem E. Vagus-nerve stimulation for the treatment of epilepsy. Lancet Neurol. 2002;1:477–82.
Ben-Menachem E, Revesz D, Simon BJ, Silberstein S. Surgically implanted and non-invasive vagus nerve stimulation: a review of efficacy, safety and tolerability. Eur J Neurol. 2015;22(9):1260–8.
Cohen-Gadol AA, Britton JW, Wetjen NM, Marsh WR, Meyer FB, Raffel C. Neurostimulation therapy for epilepsy: current modalities and future directions. Mayo Clin Proc. 2003;78:238–48.
Hatton KW, McLarney JT, Pittman T, Fahy BG. Vagal nerve stimulation: overview and implications for anesthesiologists. Anesth Analg. 2006;103:1241–9.
Wu CW, Dionigi G, Sun H, Liu X, Kim HY, Hsiao PJ, et al. Intraoperative neuromonitoring for the early detection and prevention of RLN traction injury in thyroid surgery: a porcine model. Surgery. 2014;155:329–39.
Wu CW, Lu IC, Randolph GW, Kuo WR, Lee KW, Chen CL, et al. Investigation of optimal intensity and safety of electrical nerve stimulation during intraoperative neuromonitoring of the recurrent laryngeal nerve: a prospective porcine model. Head Neck. 2010;32:1295–301.
Lamadé W, Ulmer C, Rieber F, Friedrich C, Koch KP, Thon KP. New backstrap vagus electrode for continuous intraoperative neuromonitoring in thyroid surgery. Surg Innov. 2011;18:206–13.
Schneider R, Bures C, Lorenz K, Dralle H, Freissmuth M, Hermann M. Evolution of nerve injury with unexpected EMG signal recovery in thyroid surgery using continuous intraoperative neuromonitoring. World J Surg. 2013;37:364–8.
Schneider R, Sekulla C, Machens A, Lorenz K, Thanh PN, Dralle H. Dynamics of loss and recovery of the nerve monitoring signal during thyroidectomy predict early postoperative vocal fold function. Head Neck. 2016;38:E1144–51.
Wu CW, Wang MH, Chen CC, Chen HC, Chen HY, Yu JY, et al. Loss of signal in recurrent nerve neuromonitoring: causes and management. Gland Surg. 2015;4:19–26.
Schneider R, Lorenz K, Sekulla C, Machens A, Nguyen-Thanh P, Dralle H. Surgical strategy during intended total thyroidectomy after loss of EMG signal on the first side of resection. Chirurg. 2015;86:154–63.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Electronic Supplementary Material
Below is the link to the electronic supplementary material.
This video describes two surgical approaches to the carotid sheath; placement of the Advanced Periodic Stimulation (APS)® electrode on the vagus nerve; and calibration of the continuous intraoperative neuromonitoring system. The anterior (“midline”) approach to the right carotid sheath is the preferred approach in thyroid and parathyroid surgery. The anterior approach starts with midline incision of the superficial and middle layers of the cervical fascia. The left and right strap muscles are separated and mobilized along with the right thyroid lobe. Lateral retraction of the right strap muscles together with medial retraction of the right thyroid lobe reveals the carotid sheath. After the right vagus nerve has been identified, the probe for intermittent stimulation is used to confirm the functional integrity of the whole system, vagus nerve—recurrent laryngeal nerve—vocal muscle, by eliciting normal EMG signals. The carotid sheath is then entered, and a short segment of the vagus nerve is gently dissected free so that the electrode can embrace the nerve. Utmost care is to be used not to devascularize the vagus nerve. The vagus nerve is exposed with a nerve retractor, and the APS® electrode, with the enclosure tabs open, is placed on the nerve from a 45° angle. The APS® electrode is connected with the NIM 3.0 system so that the system can auto-calibrate baselines for amplitude and latency. To enable stable and reliable signals for neuromonitoring, the amplitude is calibrated to 500 μV at least. The vagus nerve is stimulated with a current of 1 mA at a frequency of 1 Hz. Once the system is calibrated, the left pane of the NIM 3.0 monitor shows a biphasic EMG tracing, and the right monitor pane displays separate lines for amplitude and latency. The probe for intermittent stimulation is used to document these baseline parameters. The lateral approach is more useful when there is extensive scarring in the central neck, large benign or malignant goiters reach out into the lateral neck, and for dissection of lateral neck nodes. In this video sequence, the left lateral approach is demonstrated. The superficial fascia of the neck is opened alongside a virtual line formed by the lateral border of the left sternohyoid muscle and the medial border of the left sternocleidomastoid muscle. Blunt separation of the muscles reveals the carotid sheath. Once the vagus nerve has been identified, its functional integrity is confirmed using a handheld stimulation probe, which is not to be seen here. As before, the carotid sheath is entered into through a short-range incision, and a short segment of the left vagus nerve is dissected free to embrace the APS® electrode. The APS® electrode is carefully placed on the nerve that is held into position by a nerve retractor. After the APS® electrode has been hooked up to the NIM 3.0 system, the system auto-calibrates baselines for amplitude and latency. As previously, a current of 1 mA at a frequency of 1 Hz is used to stimulate the vagus nerve. After calibration, the left pane of the NIM 3.0 monitor shows a biphasic EMG tracing, and the right monitor pane displays separate lines for amplitude and latency (MP4 446957 kb)
Rights and permissions
Copyright information
© 2016 Springer International Publishing Switzerland
About this chapter
Cite this chapter
Schneider, R., Lorenz, K., Machens, A., Thanh, P.N., Randolph, G.W., Dralle, H. (2016). Continuous Intraoperative Neuromonitoring (CIONM) of the Recurrent Laryngeal Nerve. In: Randolph, G. (eds) The Recurrent and Superior Laryngeal Nerves. Springer, Cham. https://doi.org/10.1007/978-3-319-27727-1_15
Download citation
DOI: https://doi.org/10.1007/978-3-319-27727-1_15
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-27725-7
Online ISBN: 978-3-319-27727-1
eBook Packages: MedicineMedicine (R0)