Skip to main content

Subthalamic Nucleus DBS Placement for Parkinson’s Disease: Use of the microTargeting™ Frame and Waypoint™ Stereotactic System with MER Guidance

  • Chapter
  • First Online:
Book cover Surgery for Parkinson's Disease

Abstract

The subthalamic nucleus (STN) target is frequently employed as a deep brain stimulation (DBS) target for the treatment of Parkinson’s disease. This target offers the advantage of tremor reduction and L-Dopa medication reduction. When compared with other targets for the treatment of PD, such as the globus pallidus interna (GPi), some practitioners feel that the STN target may lead to greater reduction in impulse control, worsened cognitive deficits, and increased balance problems. Modern rapid prototyping methods, such as 3D printing, have made it possible to create custom skull-mounted stereotactic mini-frames (microTargeting™ platform) specific to a given patient and target. The microTargeting™ platform is a complete stereotactic system that offers several advantages including greater patient comfort, shorter surgical time on the day of lead implantation, reduced capital cost, and a shorter distance to target. Disadvantages of the system include the requirement of an extra patient visit, because the frame must be planned with imaging on a day separate from the operative day, and some constraints on targeting trajectories on the day of surgery. Waypoint planning software is coupled with the microTargeting™ platform for the purpose of trajectory planning and frame creation. Waypoint planning software includes a probabilistic atlas based on a historical cohort of patients that previously underwent DBS placement, and it can be used as an adjunct to standardized coordinates in choosing the specific location of the STN target. After the trajectories are planned and the microTargeting™ frame is produced, it is affixed to the patients’ skull on the day of lead placement. From this point, bur hole creation proceeds in the standard manner and microelectrode recording can occur simultaneously, if necessary, through both planned trajectories. Reducing the time necessary to affix the frame and plan the case on the day of surgery provides more time for MER and test stimulation and may improve patient cooperation, by shortening the surgical time.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 54.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Benabid AL, Chabardes S, Mitrofanis J, Pollak P. Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson’s disease. Lancet Neurol. 2009. https://doi.org/10.1016/S1474-4422(08)70291-6.

    Article  Google Scholar 

  2. McIntyre CC, Savasta M, Kerkerian-Le Goff L, Vitek JL. Uncovering the mechanism(s) of action of deep brain stimulation: activation, inhibition, or both. Clin Neurophysiol. 2004. https://doi.org/10.1016/j.clinph.2003.12.024.

    Article  Google Scholar 

  3. Charles D, Konrad PE, Neimat JS, et al. Subthalamic nucleus deep brain stimulation in early stage Parkinson’s disease. Parkinsonism Relat Disord. 2012;20:731–7. https://doi.org/10.1016/j.parkreldis.2014.03.019.

    Article  Google Scholar 

  4. Konrad PE, Neimat JS, Yu H, et al. Customized, miniature rapid-prototype stereotactic frames for use in deep brain stimulator surgery: initial clinical methodology and experience from 263 patients from 2002 to 2008. Stereotact Funct Neurosurg. 2011. https://doi.org/10.1159/000322276.

    Article  Google Scholar 

  5. Kelman C, Ramakrishnan V, Davies A, Holloway K. Analysis of stereotactic accuracy of the cosman-robert-wells frame and nexframe frameless systems in deep brain stimulation surgery. Stereotact Funct Neurosurg. 2010;88(5):288–95. https://doi.org/10.1159/000316761.

    Article  PubMed  Google Scholar 

  6. D’haese PF, Pallavaram S, Konrad PE, Neimat J, Fitzpatrick JM, Dawant BM. Clinical accuracy of a customized stereotactic platform for deep brain stimulation after accounting for brain shift. Stereotact Funct Neurosurg. 2010. https://doi.org/10.1159/000271823.

    Article  Google Scholar 

  7. Stuart RM, Goodman RR. Novel use of a custom stereotactic frame for placement of depth electrodes for epilepsy monitoring. Neurosurg Focus. 2008. https://doi.org/10.3171/FOC/2008/25/9/E20.

    Article  Google Scholar 

  8. Follett KA, Weaver FM, Stern M, et al. Pallidal versus subthalamic deep-brain stimulation for Parkinson’s disease. N Engl J Med. 2010;362:2077–91. https://doi.org/10.1056/NEJMoa0907083.

    Article  CAS  PubMed  Google Scholar 

  9. Camalier CR, Konrad PE, Gill CE, et al. Methods for surgical targeting of the stn in early-stage Parkinson’s disease. Front Neurol. 2014. https://doi.org/10.3389/fneur.2014.00025.

  10. Pallavaram S, D’Haese P-F, Lake W, Konrad PE, Dawant BM, Neimat JS. Fully automated targeting using nonrigid image registration matches accuracy and exceeds precision of best manual approaches to subthalamic deep brain stimulation targeting in Parkinson disease. Neurosurgery. 2015;1. https://doi.org/10.1227/NEU.0000000000000714.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Joseph S. Neimat .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Lake, W., Sukul, V., Neimat, J.S. (2019). Subthalamic Nucleus DBS Placement for Parkinson’s Disease: Use of the microTargeting™ Frame and Waypoint™ Stereotactic System with MER Guidance. In: Goodman, R. (eds) Surgery for Parkinson's Disease. Springer, Cham. https://doi.org/10.1007/978-3-319-23693-3_3

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-23693-3_3

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-23692-6

  • Online ISBN: 978-3-319-23693-3

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics