Skip to main content

New Measurement Method of Three-Phase Voltage Unbalance Rate Based on DSOGI-PLL

  • Conference paper
  • First Online:
Advances in Intelligent Systems and Interactive Applications (IISA 2019)

Part of the book series: Advances in Intelligent Systems and Computing ((AISC,volume 1084))

  • 1003 Accesses

Abstract

Three-phase Voltage Unbalance Rate (TPVUR) is an important indicator to measure power quality, whose accurate measurement requires fast and accurate extraction of fundamental sequence component. Considering harmonic interference and shortcomings that Vector Symmetric Component (VSC) is only suitable for extracting sequence components in steady-state circuits. A new measurement method of TPVUR based on Double Second Order Generalized Integrator-Phase Locked Loop (DSOGI-PLL) and Instantaneous Symmetrical Component (ISC) has been put forward. Firstly, the three-phase voltage signal is converted to the \( \alpha \beta \) signal in two-phase stationary coordinate system, and then the DSOGI-PLL and the ISC are combined to filter out the harmonics and extract the instantaneous positive sequence and negative sequence components of fundamental, thereby the real-time measurement of TPVUR are realized. Simulink simulation results show that the new method not only satisfies the real-time detection of TPVUR, but also achieves the same accuracy as the recommended algorithm in GB/T 15543-2008 and IEC-6100-4-27-2015.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Zhe, W., Yiru, W., et al.: Development status of China’s renewable energy power generation. In: IEEE International Conference on Sustainable Power Generation and Supply (2009)

    Google Scholar 

  2. Singh, M., Allen, A., Hodge, B.-M.S.: Grid connection and power conditioning of wind farms. In: Handbook of Clean Energy Systems (2004)

    Google Scholar 

  3. Yang, C., Meng, H., et al.: The transient response analysis of SRF-PLL under the unbalance grid voltage sag. Trans. China Electro Tech. Soc. S2, 34–44 (2016)

    Google Scholar 

  4. Kabiri, R., et al.: Control of active and reactive power ripple to mitigate unbalanced grid voltages. IEEE Trans. Ind. Appl. 52(2), 1660–1668 (2015)

    Article  Google Scholar 

  5. Hao, P., Li, D., et al.: An improved algorithm for harmonic analysis of power system using FFT technique. Proc. CSEE 23(6), 50–54 (2003)

    Google Scholar 

  6. Wen, H., Teng, Z., et al.: Simple interpolated FFT algorithm based on minimize side lobe windows for power-harmonic analysis. IEEE Trans. Power Electron. 26(9), 2570–2579 (2011)

    Article  Google Scholar 

  7. Bing, J., Zhirui, L., Shengsuo, N.: FFT harmonic analysis based on nine terms minimum side-lobe cosine-sum window. Electr. Power Sci. Eng. 28(10) (2012)

    Google Scholar 

  8. He, W., Ran, J., et al.: Fast measurement method of voltage unbalance factor based on windowed FFT. Trans. China Electro Tech. Soc. 32(16), 275–283 (2017)

    Google Scholar 

  9. Rodriguez, P., Teodorescu, R., et al.: New positive-sequence voltage detector for grid synchronization of power converters under faulty grid conditions. In: IEEE Power Electronics Specialists Conference, pp. 1–7 (2006)

    Google Scholar 

  10. Yuan, X.: An improved method of instantaneous symmetrical components and its detection for positive and negative sequence current. Proc. CSEE 28(1) (2008)

    Google Scholar 

  11. Zhu, J.: Three-phase four-wire D-STATCOM control based on instantaneous symmetrical component method. Electr. Meas. Instrum. 51(23) (2013)

    Google Scholar 

  12. Ghijselen, B.: Exact voltage unbalance assessment without phase measurements. IEEE Trans. Power Syst. 20(1), 519–520 (2005)

    Article  Google Scholar 

  13. Lyon. Discussion on “transient conditions in electric machinery”. J. Am. Inst. Electr. Eng. 42(10), 1076–1078 (1923)

    Google Scholar 

  14. Rasheduzzaman, M., Khorbotly, S.: A modified SRF-PLL for phase and frequency measurement of single-phase systems. In: IEEE Energy Conversion Congress and Exposition (2017)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jiafeng Ding .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Yu, C. et al. (2020). New Measurement Method of Three-Phase Voltage Unbalance Rate Based on DSOGI-PLL. In: Xhafa, F., Patnaik, S., Tavana, M. (eds) Advances in Intelligent Systems and Interactive Applications. IISA 2019. Advances in Intelligent Systems and Computing, vol 1084. Springer, Cham. https://doi.org/10.1007/978-3-030-34387-3_57

Download citation

Publish with us

Policies and ethics