Abstract
When reconstructing existing school buildings and building new buildings, great emphasis is placed on increasing their thermal resistance and reducing air tightness. The consequence of these modifications is the reduction of heat flow through the building structure, as well as minimization of uncontrolled ventilation by infiltration through building leaks. According to various studies conducted in the world, it can be said that the exchange of used air for fresh air has a huge impact on the mood of students in the classroom. As part of a research stay at the Lviv Polytechnic, measurements were made in the classroom to determine the air quality during the teaching. The classroom was selected in which measuring instruments were installed for measuring carbon dioxide (CO2) concentration and air temperature. During the measurements didactic classes took place in the classroom. In addition to the measurement of indoor air parameters, a subjective assessment of air quality was carried out using questionnaires. The students filled out the indoor air quality questionnaire at the beginning of their stay in the auditorium at the end of their stay. An assessment of air quality was carried out based on the measured air parameters and questionnaire ratings in the selected classroom.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Abdel-Salam MMM (2019) Investigation of indoor air quality at urban schools in Qatar. Indoor Built Environ 28(2):278–288. https://doi.org/10.1177/1420326x17700948 ISSN: 1420326X
Becker R, Goldberger I, Paciuk M (2007) Improving energy performance of school buildings while ensuring indoor air quality ventilation. Build Environ 42(9):3261–3276. https://doi.org/10.1016/j.buildenv.2006.08.016 ISSN: 0360-1323
Carlos JS (2017) The impact of refurbished windows on Portuguese old school buildings. Architect Eng Des Manag 13(3):185–201. https://doi.org/10.1080/17452007.2016.1274252
Ghaddar N, Ghali K, Chehaitly S (2011) Assessing thermal comfort of active people in transitional spaces in presence of air movement. Energy Build 43(10):2832–2842. https://doi.org/10.1016/j.enbuild.2011.06.040
Han DH, Kim S, Choi JH, Kim YS, Chung HS, Jeong H, Choi SO, Watjanatepin N, Ruangpattanawiwat Ch (2018) Experimental study on thermal buoyancy-induced natural ventilation. Energy Build 177:1–11. https://doi.org/10.1016/j.enbuild.2018.07.046 ISSN: 0378-7788
Hooff T, Blocken B, Hensen JLM, Timmermans HJP (2014) On the predicted effectiveness of climate adaptation measures for residential buildings. Build Environ 82:300–316. https://doi.org/10.1016/j.buildenv.2014.08.027
Hou YF, Liu JJ, Li JY (2015) Investigation of indoor air quality in primary school classrooms. Procedia Eng 121(2015):830–837. https://doi.org/10.1016/j.proeng.2015.09.037
Chen Y, Tong Z, Malkawi A (2017) Investigating natural ventilation potentials across the globe: regional and climatic variations. Build Environ 122:386–396. https://doi.org/10.1016/j.buildenv.2017.06.026
Jovanovic M, Vucicevic B, Turanjanin V, Zivkovic M, Spasojevic V (2014) Investigation of indoor and outdoor air quality of the classrooms at a school in Serbia. Energy 77:42–48. https://doi.org/10.1016/j.energy.2014.03.080
Kapalo P, Meciarova L, Vilcekova S, Burdova EK, Domnita F, Bacotiu C, Peterfi KE (2019) Investigation of CO2 production depending on physical activity of students. Int J Environ Health Res 29(1):31–44. https://doi.org/10.1080/09603123.2018.1506570 ISSN: 09603123
Karimipanah T, Awbi HB, Sandberg M, Blomqvist C (2007) Investigation of air quality, comfort parameters and effectiveness for two floor-level air supply systems in classrooms. Build Environ 42(2):647–655. https://doi.org/10.1016/j.buildenv.2005.10.016
Krawczyk DA, Rodero A, Gładyszewska-Fiedoruk K, Gajewski A (2016) CO2 concentration in naturally ventilated classrooms located in different climates – measurements and simulations. Energy Build 129:491–498
Meciarova L, Vilcekova S, Kridlova Burdova E, Kapalo P, Mihalova N (2018) The real and subjective indoor environmental quality in schools. Int J Environ Health Res 28(1):102–123. https://doi.org/10.1080/09603123.2018.1429579 ISSN: 09603123
Merema B, Delwati M, Sourbron M, Breesch H (2018) Demand controlled ventilation (DCV) in school and office buildings: lessons learnt from case studies. Energy Build 172:349–360. https://doi.org/10.1016/j.enbuild.2018.04.065
Schibuola L, Scarpa M, Tambani Ch (2016) Natural ventilation level assessment in a school building by CO2 concentration measures. Energy Procedia 101:257–264. https://doi.org/10.1016/j.egypro.2016.11.033
Teleszewski T, Gładyszewska-Fiedoruk K (2018) Changes of carbon dioxide concentration in classrooms - simplified model and experimental verification. Pol J Environ Stud 27(5):2397–2403. https://doi.org/10.15244/pjoes/77074
Acknowledgements
This article was elaborated in the framework of the project VEGA 1/0697/17. The article was written during a research stay at the National University “Lviv Polytechnic”.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Kapalo, P., Klymenko, H., Zhelykh, V., Adamski, M. (2020). Investigation of Indoor Air Quality in the Selected Ukraine Classroom – Case Study. In: Blikharskyy, Z., Koszelnik, P., Mesaros, P. (eds) Proceedings of CEE 2019. CEE 2019. Lecture Notes in Civil Engineering , vol 47. Springer, Cham. https://doi.org/10.1007/978-3-030-27011-7_21
Download citation
DOI: https://doi.org/10.1007/978-3-030-27011-7_21
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-27010-0
Online ISBN: 978-3-030-27011-7
eBook Packages: EngineeringEngineering (R0)