Many physics analyses using the Compact Muon Solenoid (CMS) detector at the LHC require accurate electron and photon energy measurements. Excellent energy resolution is crucial for the study of Higgs boson decays with electromagnetic particles in the final state, as well as searches for very high mass resonances decaying to energetic photons or electrons. The CMS electromagnetic calorimeter (ECAL) is presently operating at the LHC with proton-proton collisions at 13 TeV center-of-mass energy, 25 ns bunch spacing, and an unprecedented instantaneous luminosity. High pileup levels and the ageing of crystals from exposure to large particle fluencies necessitate a retuning of the ECAL readout, trigger thresholds, and reconstruction algorithms, to maintain the best possible performance in these increasingly challenging conditions. In addition, the energy response of the detector must be precisely calibrated and monitored, injecting laser light to correct for crystal transparency changes due to irradiation. A dedicated calibration of each detector channel is performed with physics events exploiting electrons from W and Z boson decays, photons from pi0 decays, and from the azimuthally symmetric energy distribution of minimum bias events. This talk presents the new reconstruction algorithm and calibration strategies that have been implemented and the excellent performance achieved by the CMS ECAL throughout LHC Run II.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
The CMS Collaboration, The CMS experiment at the CERN LHC. JINST 3, S08004 (2008)
M. Anfreville et al., Laser monitoring system for the CMS lead tungstate crystal calorimeter. Nucl. Instrum. Meth. A 594, 292 (2008)
[CMS Collaboration] Energy Calibration and Resolution of the CMS Electromagnetic Calorimeter in pp Collisions at sqrt(s) = 7 TeV, JINST 8, P09009 (2013)
[CMS Collaboration] Performance of Electron Reconstruction and Selection with the CMS Detector in Proton-Proton Collisions at √s = 8 TeV JINST 10, P06005 (2015)
[CMS Collaboration] Performance of Photon Reconstruction and Identification with the CMS Detector in Proton-Proton Collisions at √s = 8 TeV JINST 10, P08010 (2015)
Author information
Authors and Affiliations
Consortia
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Dimova, T., on behalf of the CMS Collaboration. (2019). Calibration and Performance of the CMS Electromagnetic Calorimeter During the LHC Run II. In: Korzhik, M., Gektin, A. (eds) Engineering of Scintillation Materials and Radiation Technologies. ISMART 2018. Springer Proceedings in Physics, vol 227. Springer, Cham. https://doi.org/10.1007/978-3-030-21970-3_22
Download citation
DOI: https://doi.org/10.1007/978-3-030-21970-3_22
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-21969-7
Online ISBN: 978-3-030-21970-3
eBook Packages: Physics and AstronomyPhysics and Astronomy (R0)