Skip to main content

Effect of Biomaterial (Citrullus Lanatus Peels) Nanolubricant on the Thermal Performance and Energy Consumption of R600a in Refrigeration System

  • Conference paper
  • First Online:
Energy Technology 2019

Abstract

The study experimentally investigated the combinatorial impact of bio-based nanoparticles from agriculture waste of Citrullus Lanatus (watermelon) peels on the improvement of thermal performance and energy consumption of R600a as an alternative refrigerant to environment malignant R134a in a domestic refrigeration system. The thermodynamic system includes Copeland 46B/R600a or R134a as control and bio-based nanolubricant /R600a at different concentrations as test samples. The outcome showed that despite the results of coefficient of performance and pull-down time for the conventional R134a refrigerant fluid system, the R600a and its nanorefrigerant fluid variants performed better in terms of energy consumption, cooling capacity, and quantity of heat absorbed and expelled. Thus, reconfiguration of the thermodynamic system with bio-based nanoparticles had effect on the performance and improvement of R600a as a worthy refrigerant alternative to R134a.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Paul Sudipta, Sarkar Achinta, Mandal Bijan Kumar (2013) Environmental impacts of halogenated refrigerants and their alternatives: recent developments. International Journal of Emerging Technology and Advanced Engineering 3(3):400–409

    Google Scholar 

  2. Mohd. Aasim Nazeer Ahmad, Chidanand Mangrulkar, Ehsanullah Khan, Syed Mohiuddin, (2014). Experimental analysis of refrigerator by replacing conventional HFC refrigerants with hydrocarbons, IOSR Journal of Mechanical and Civil Engineering, 1–5

    Google Scholar 

  3. Ajayi OO (2017) Legal Response to Mitigation Strategies for Climate Change in Nigeria. Bowen University Law Journal 1:221–235

    Google Scholar 

  4. Ajayi Oluwatoyin O (2017) The Nigerian National Climate Change Bill: A Review. Ife Journal of International and Comparative Law 3(1):96–108

    Google Scholar 

  5. Bhatkar VW, Kriplani VM, Awari GK (2013) Alternative refrigerants in vapour compression refrigeration cycle for sustainable environment: a review of recent research. Int J Environ Sci Technol 10(4):871–880

    Article  CAS  Google Scholar 

  6. Okolo Teddy I, Ajayi Oluseyi O (2018) Thermal Performance and Energy Consumption Analyses of R290 and R22 Refrigerants in Air-conditioning System. IOPS conference series: Material Science and Engineering 413:012072. https://doi.org/10.1088/1757-899X/413/1/012072

    Article  Google Scholar 

  7. Mahajan Rajanikant Y, Borikar Sanjaykumar A (2014) Performance Evaluation of Domestic Refrigerator Using Hc-12a Refrigerant as an Alternative Refrigerant to R12 And R134a. International Journal of Engineering and Science 3(10):26–27

    Google Scholar 

  8. Gill Jatinder, Singh Jagdev (2017) Energy analysis of vapor compression refrigeration system using mixture of 134a and LPG as refrigerant. Int J Refrig 84:287–299

    Article  CAS  Google Scholar 

  9. Wongwises S, Chimres N (2005) Experimental study of hydrocarbon mixtures to replace HFC134a in domestic refrigerators. Energy Convers Manag 46:85–100

    Article  CAS  Google Scholar 

  10. Bolaji BO, Oyelaran OA, Okoye OC (2017) Thermodynamic study of environment-friendly R429A, R435A and R457A refrigerants as substitutes for ozone depleting R22 in refrigeration and air-conditioning systems. Scientific Journal of Maritime Research 31:45–52

    Google Scholar 

  11. Azmi, W.H. Sharif, M.Z. Yusof, T.M. Rizalman Mamata, Redhwan, A.A.M., (2017). Potential of nanorefrigerant and nanolubricant on energy saving in refrigeration system – A review, Renewable and Sustainable Energy Reviews, 69, 415–428

    Article  CAS  Google Scholar 

  12. Vipin Nair PR, Tailor AD Parekh (2016) Nanorefrigerants: A comprehensive review on its past, present and future. Int J Refrig 67:290–307

    Article  Google Scholar 

  13. Ajayi Oluseyi O, Ibia Dorothy E, Ogbonnaya Mercy, Attabo Ameh, Michael Agarana (2017) CFD analysis of nanorefrigerant through adiabatic capillary tube of vapour compression refrigeration system. Procedia Manufacturing 7:688–695

    Article  Google Scholar 

  14. Ajayi Oluseyi O, Useh Oghenefegor O, Banjo Solomon O, Oweoye Felicia T, Attabo Ameh, Ogbonnaya Mercy, Okokpujie Imhade P, Enesi Y Salawu (2018) Investigation of the heat transfer effect of Ni/R134a nanorefrigerant in a mobile hybrid powered vapour compression refrigerator. IOP Conference Series: Mater. Sci. Eng. 391:012001. https://doi.org/10.1088/1757-899X/391/1/012001

    Article  Google Scholar 

  15. Xing Meibo, Wang Ruixiang, Jianlin Yu (2014) Applicationof fullereneC60nano-oil for performance enhancement of domestic refrigerator compressors. Int J Refrig 40:398–403

    Article  CAS  Google Scholar 

  16. Kumar DS, Elansezhian R (2012) Experimental Study on Al2O3-R134a Nano Refrigerant in Refrigeration System. International Journal of Modern Engineering Research 2(5):3927–3929

    Google Scholar 

  17. Bi Shengshan, Guo Kai, Liu Zhigang, Jiangtao Wu (2011) Performance of a domestic refrigerator using TiO2-R600a nano-refrigerant as working fluid. Energy Convers Manag 52:733–737

    Article  CAS  Google Scholar 

Download references

Acknowledgements

The authors wish to appreciate the management of Covenant University for the part sponsorship of this research and Tshwane University of Technology for the platform provided towards the completion of this research.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Oluseyi O. Ajayi .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 The Minerals, Metals & Materials Society

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Ajayi, O.O. et al. (2019). Effect of Biomaterial (Citrullus Lanatus Peels) Nanolubricant on the Thermal Performance and Energy Consumption of R600a in Refrigeration System. In: Wang, T., et al. Energy Technology 2019. The Minerals, Metals & Materials Series. Springer, Cham. https://doi.org/10.1007/978-3-030-06209-5_9

Download citation

Publish with us

Policies and ethics