Abstract
This study aims to assess the effects of using wood stoves on indoor air quality (IAQ) regarding fine PM, ultrafine PM, CO2 and relative humidity in Norwegian residential houses. Measurements were performed in an old natural ventilated house and a new mechanical ventilated house. Three locations for PM measurements were selected: close to the stove opening, in the middle of the room and at the supply air inlet, with original installed stoves typical for the buildings’ time of construction. Each measurement lasted 3 h, which includes monitoring of the background concentration, the light up process, the burning and the refill processes. The results show peaks of fine and ultrafine PM emissions during the light up and refill phases, connected to opening of the wood stove door. The ultrafine PM peaks were higher and occurred more frequently than the fine PM ones, indicating that not only the opening of the wood stove door caused these PM peaks. Significant differences were found between the two houses regarding the relative distribution between fine PM and ultrafine PM. Peak concentrations of ultrafine PM took longer time to fall back towards background levels compared to the fine PM concentrations. No clear correlations were found between the load of the stove and PM emissions, and further research is required to assess why. Yet the situation was not alarming as the 24 h mean PM2.5 concentration in both houses was below the WHO guideline. CO2 emissions in both houses were on average always at a healthy level.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
R. Ruckerl, A. Schneider, S. Breitner, J. Cyrys, A. Peters, Health effects of particulate air pollution: a review of epidemiological evidence. Inhalation Toxicol. 23(10), 555–592 (2011). https://doi.org/10.3109/08958378.2011.593587
K.A. Miller et al., Long-term exposure to air pollution and incidence of cardiovascular events in women. N. Engl. J. Med. 356, 447–458 (2007). https://doi.org/10.1056/nejmoa054409
P. Wargocki et al., Ventilation and health in non-industrial indoor environments: report from a european multidisciplinary scientific consensus meeting (EUROVEN). Indoor Air 12(2), 113–128 (2002). https://doi.org/10.1034/j.1600-0668.2002.01145.x
J. Sundell, H. Levin, W.W. Nazaroff, W.S. Cain, W.J. Fisk, D.T. Grimsrud, F. Gyntelberg et al., Ventilation rates and health: multidisciplinary review of the scientific literature. Indoor Air 21(3), 191–204 (2011). https://doi.org/10.1111/j.1600-0668.2010.00703.x
Direktoratet for byggkvalitet TEK10, 13.2 Ventilasjon i boenhet. https://dibk.no/byggeregler/tek/3/13/i/13-2/
Sweden building code, Boverket, BBR19 BFS 2011:26. http://www.boverket.se/en/start-in-english/publications/2012/building-regulations-bbr/
D2 Suomen rakentamismääräyskokoelma Ympäristöministeriö, Rakennetun ympäristön osasto. http://www.finlex.fi/data/normit/37187/D2-2012_Suomi.pdf
Danish Building Regulations BR15. http://bygningsreglementet.dk/file/591081/br15_english.pdf
A.B. Wyss et al., Particulate matter 2.5 exposure and self-reported use of wood stoves and other indoor combustion sources in urban nonsmoking homes in Norway. PLOS One 11(11), e0166440 (2016). https://doi.org/10.1371/journal.pone.0166440
R.W. Allen et al., The impact of wood stove technology upgrades on indoor residential air quality. Atmos. Environ. 43(37), 5908–5915 (2009). https://doi.org/10.1016/j.atmosenv.2009.08.016
B. Lévesque et al., Wood-burning appliances and indoor air quality. Sci. Total Environ. 281(1–3), 47–62 (2001). https://doi.org/10.1016/s0048-9697(01)00834-8
G. Cao et al., Experimental study of indoor air quality in two types of Norwegians houses heated by wood stove, NTNU, SINTEF (2015)
L.P. Naeher, M. Brauer, M. Lipsett et al., Woodsmoke health effects: a review. Inhalation Toxicol. 19, 67–106 (2007). https://doi.org/10.1080/08958370600985875
B.F. Yu et al., Review of research on air-conditioning systems and indoor air quality control for human health. Int. J. Refrig. 32(1), 3–20 (2009). https://doi.org/10.1016/j.ijrefrig.2008.05.004
J. Froines, Ultrafine Particle Health Effects. (2006). http://www.aqmd.gov/docs/default-source/technology-research/ultrafine-particles-conference/pre-conference_2_froines.pdf?sfvrsn=2
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Hamon, M. et al. (2019). Assessment of the Effects of Using Wood Stoves on Indoor Air Quality in Two Types of Norwegian Houses. In: Johansson, D., Bagge, H., Wahlström, Å. (eds) Cold Climate HVAC 2018. CCC 2018. Springer Proceedings in Energy. Springer, Cham. https://doi.org/10.1007/978-3-030-00662-4_75
Download citation
DOI: https://doi.org/10.1007/978-3-030-00662-4_75
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-00661-7
Online ISBN: 978-3-030-00662-4
eBook Packages: EnergyEnergy (R0)