Skip to main content

Performance Evaluation of a Passive House in Sub-arctic Climate

  • Conference paper
  • First Online:
Cold Climate HVAC 2018 (CCC 2018)

Part of the book series: Springer Proceedings in Energy ((SPE))

Included in the following conference series:

  • 1401 Accesses

Abstract

As the operational energy use in buildings contributes highly to the total energy used and greenhouse gases emitted in the cold climate regions of Europe, buildings which are more energy-efficient and less carbon-intensive during operation are key to meet sustainability objectives in these regions. Yet, research shows that the practice of passive or low-energy buildings in the sub-arctic climate of northern Sweden is comparatively less than in the southern region. Moreover, previous studies did not explicitly examine the performance of low energy buildings in sub-arctic climate in relation to established building energy efficiency standards. Consequently, knowledge regarding the energy performance of low-energy buildings in such climate is limited. Therefore, the aim is to evaluate the performance, in terms of indoor temperature and energy use for heating, domestic hot water and electricity of a new-built passive house titled “Sjunde Huset” in the sub-arctic town of Kiruna. It is Sweden’s northernmost house designed to fulfil the Swedish passive-house criteria of a maximum heat loss factor of 17 W/m2 and a maximum annual energy use of 63 kWh/m2. The implemented passive design strategies include a highly insulated, compact and airtight building envelope with a vestibule, mechanical ventilation with heat recovery and renewable energy production through photovoltaic solar cells. The house is connected to district heating and is equipped with energy-efficient appliances to allow low occupant energy use. Ongoing performance evaluation is based on building simulation and measurements of energy and temperature in different zones of the building. Energy performance deviations between occupied and non-occupied zones are explored through internal heat gain evaluations. The indoor temperature is also evaluated to assess the temperature variations throughout the year. The ongoing research further evaluate a comparative simulated and measured energy analysis of heating, hot water and electricity based on both the international passive house standard and the Swedish passive house criteria “Feby 12”.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. D. Risberg, M. Vesterlund, L. Westerlund, J. Dahl, CFD simulation and evaluation of different heating systems installed in low energy building located in sub-arctic climate. Build. Environ. 89, 160–169 (2015)

    Article  Google Scholar 

  2. P. Mukhopadhyaya, D. MacLean, J. Korn, D. Van Reenen, S. Molleti, Building application and thermal performance of vacuum insulation panels (VIPs) in Canadian subarctic climate. Energy Build. 85, 672–680 (2014)

    Article  Google Scholar 

  3. P. Vladyková, C. Rode, T.R. Nielsen, S. Pedersen, Passive houses for arctic: measures and alternatives, in 13th International Passive House Conference, Germany 2009

    Google Scholar 

  4. NCC Report. Sjunde huset–ett lågenergiparhus i Kiruna, Slutrapport 38548-1, Energymyn-digheten, May 2017

    Google Scholar 

  5. SVEBY: Branschstandard för energi i byggnader. Brukarindata för energiberäkningar i bo- städer. Projektrapport, April, 2009

    Google Scholar 

  6. Swedish Meteorological and Hydrological Institute (SMHI) Homepage, https://opendata-download-metobs.smhi.se/explore/?parameter=0. Last accessed 14 Sep 2017

  7. FEBY (Forum for energy-efficient buildings) Homepage, http://www.nollhus.se/. Last accessed 14 Sep 2017

  8. Passive House Institute Homepage (Passivhaus Institute), www.passiv.de, http://www.passiv.de/downloads/03_building_criteria_en.pdf. Last accessed 15 Oct 2015

Download references

Acknowledgements

We greatly acknowledge the financial support of Vinnova (Sweden’s Innovation Agency), HLRC (Hjalmar Lundbohm Research Center) and the partner companies through the project Attract (Attractive and Sustainable Cities in Cold Climates) and of the European Union Interreg North program through the project EEBAK (Energi Effektiva Byggnader i Arktiska Kommuner).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shimantika Bhattacharjee .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Bhattacharjee, S., Lidelöw, S., Schade, J. (2019). Performance Evaluation of a Passive House in Sub-arctic Climate. In: Johansson, D., Bagge, H., Wahlström, Å. (eds) Cold Climate HVAC 2018. CCC 2018. Springer Proceedings in Energy. Springer, Cham. https://doi.org/10.1007/978-3-030-00662-4_13

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-00662-4_13

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-00661-7

  • Online ISBN: 978-3-030-00662-4

  • eBook Packages: EnergyEnergy (R0)

Publish with us

Policies and ethics