Abstract
As the operational energy use in buildings contributes highly to the total energy used and greenhouse gases emitted in the cold climate regions of Europe, buildings which are more energy-efficient and less carbon-intensive during operation are key to meet sustainability objectives in these regions. Yet, research shows that the practice of passive or low-energy buildings in the sub-arctic climate of northern Sweden is comparatively less than in the southern region. Moreover, previous studies did not explicitly examine the performance of low energy buildings in sub-arctic climate in relation to established building energy efficiency standards. Consequently, knowledge regarding the energy performance of low-energy buildings in such climate is limited. Therefore, the aim is to evaluate the performance, in terms of indoor temperature and energy use for heating, domestic hot water and electricity of a new-built passive house titled “Sjunde Huset” in the sub-arctic town of Kiruna. It is Sweden’s northernmost house designed to fulfil the Swedish passive-house criteria of a maximum heat loss factor of 17 W/m2 and a maximum annual energy use of 63 kWh/m2. The implemented passive design strategies include a highly insulated, compact and airtight building envelope with a vestibule, mechanical ventilation with heat recovery and renewable energy production through photovoltaic solar cells. The house is connected to district heating and is equipped with energy-efficient appliances to allow low occupant energy use. Ongoing performance evaluation is based on building simulation and measurements of energy and temperature in different zones of the building. Energy performance deviations between occupied and non-occupied zones are explored through internal heat gain evaluations. The indoor temperature is also evaluated to assess the temperature variations throughout the year. The ongoing research further evaluate a comparative simulated and measured energy analysis of heating, hot water and electricity based on both the international passive house standard and the Swedish passive house criteria “Feby 12”.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
D. Risberg, M. Vesterlund, L. Westerlund, J. Dahl, CFD simulation and evaluation of different heating systems installed in low energy building located in sub-arctic climate. Build. Environ. 89, 160–169 (2015)
P. Mukhopadhyaya, D. MacLean, J. Korn, D. Van Reenen, S. Molleti, Building application and thermal performance of vacuum insulation panels (VIPs) in Canadian subarctic climate. Energy Build. 85, 672–680 (2014)
P. Vladyková, C. Rode, T.R. Nielsen, S. Pedersen, Passive houses for arctic: measures and alternatives, in 13th International Passive House Conference, Germany 2009
NCC Report. Sjunde huset–ett lågenergiparhus i Kiruna, Slutrapport 38548-1, Energymyn-digheten, May 2017
SVEBY: Branschstandard för energi i byggnader. Brukarindata för energiberäkningar i bo- städer. Projektrapport, April, 2009
Swedish Meteorological and Hydrological Institute (SMHI) Homepage, https://opendata-download-metobs.smhi.se/explore/?parameter=0. Last accessed 14 Sep 2017
FEBY (Forum for energy-efficient buildings) Homepage, http://www.nollhus.se/. Last accessed 14 Sep 2017
Passive House Institute Homepage (Passivhaus Institute), www.passiv.de, http://www.passiv.de/downloads/03_building_criteria_en.pdf. Last accessed 15 Oct 2015
Acknowledgements
We greatly acknowledge the financial support of Vinnova (Sweden’s Innovation Agency), HLRC (Hjalmar Lundbohm Research Center) and the partner companies through the project Attract (Attractive and Sustainable Cities in Cold Climates) and of the European Union Interreg North program through the project EEBAK (Energi Effektiva Byggnader i Arktiska Kommuner).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Bhattacharjee, S., Lidelöw, S., Schade, J. (2019). Performance Evaluation of a Passive House in Sub-arctic Climate. In: Johansson, D., Bagge, H., Wahlström, Å. (eds) Cold Climate HVAC 2018. CCC 2018. Springer Proceedings in Energy. Springer, Cham. https://doi.org/10.1007/978-3-030-00662-4_13
Download citation
DOI: https://doi.org/10.1007/978-3-030-00662-4_13
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-00661-7
Online ISBN: 978-3-030-00662-4
eBook Packages: EnergyEnergy (R0)