Abstract
This paper describes performance test results for the Ball Flight Prototype single-stage split Stirling cycle cryocooler, which was selected for use on the AXAF X-ray Spectrometer/Cryogenic Subsystem (XRS/CSS).
The cryocooler incorporates the basic Oxford heritage cryocooler design acquired by Ball from Rutherford Appleton Laboratory. Two opposed compressors are connected to a momentum compensated single-stage integral displacer/regenerator coldhead.
Thermal performance in a vacuum environment from −40 ° C to +50 °C arc described as well as control of vibration, coldtip temperature control, EMI measurements, and the results of testing of modifications to increase the environmental operating temperature range. Ongoing life test results are also discussed.
The next generation Advanced Flight Prototype will be tested during the summer of 1994. It is ready to be incorporated into a flight system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
E-mail address: bhorsley@ball.com
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1995 Springer Science+Business Media New York
About this chapter
Cite this chapter
Horsley, W.J. et al. (1995). Test Results for the Single-Stage Ball Flight Prototype Cooler. In: Ross, R.G. (eds) Cryocoolers 8. Springer, Boston, MA. https://doi.org/10.1007/978-1-4757-9888-3_3
Download citation
DOI: https://doi.org/10.1007/978-1-4757-9888-3_3
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4757-9890-6
Online ISBN: 978-1-4757-9888-3
eBook Packages: Springer Book Archive