Skip to main content

XEN Gel Stent: The Solution Designed by AqueSys®

  • Chapter
  • First Online:
Book cover Surgical Innovations in Glaucoma

Abstract

XEN Gel Stent is the solution developed by AqueSys, Inc. by merging together the best of both worlds: a long time proven outflow mechanism of action at the subconjunctival space with a minimally invasive approach creating Minimally Invasive Maximum Efficacy technology (MIME).

A detailed explanation of the rationale and calculations are given to allow the reader to get a complete comprehension of the science behind the XEN Gel Stent.

The surgical technique is summarized in 10 simple steps with images and videos from real surgery and animations.

Results from international studies showed a reduction of 38 % of the mean IOP at 24 months and a reduction of 48 % of medications at 24 months from best medicated IOP. One hundred and eighteen patients were enrolled in the study with a mean preoperative IOP of 23 mmHg (non-washed-out IOP value). At postoperative, the mean IOPs were 15.4 at 12 months, 14.5 at 18 months, and 14.3 at 24 months. The mean decrease in IOP (mmHg) was −7.6 (−33 % reduction) at 12 months and −8.5 (−37 % reduction) at 18 months from best medicated IOP.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 59.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 79.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Watson PG, Jakeman C, Ozturk M, Barnett MF, Barnett F, Khaw KT. Complications of trabeculectomy (a 20-year follow-up). Eye (Lond). 1990;4:425–38.

    Article  Google Scholar 

  2. Nouri-Mahdavi K, Brigatti L, Weitzman M, Caprioli J. Outcomes of trabeculectomy for primary open-angle glaucoma. Ophthalmology. 1995;102:1760–9.

    Article  CAS  PubMed  Google Scholar 

  3. Ticho U, Ophir A. Late complications after glaucoma filtering surgery with adjunctive 5-fluorouracil. Am J Ophthalmol. 1993;115:506–10.

    CAS  PubMed  Google Scholar 

  4. Costa VP, Wilson RP, Moster M, Schmidt CM, Gandham S. Hypotony maculopathy following the use of topical mitomycin C in glaucoma filtration surgery. Ophthalmic Surg. 1993;24:389–94.

    CAS  PubMed  Google Scholar 

  5. Topouzis F, Coleman AL, Choplin N, Bethlem MM, Hill R, Yu F, Panek WC, Wilson MR. Follow-up of the original cohort with the Ahmed glaucoma valve implant. Am J Ophthalmol. 1999;128:198–204.

    Article  CAS  PubMed  Google Scholar 

  6. Smith SL, Starita RJ, Fellman RL, Lynn JR. Early clinical experience with the Baerveldt 350-mm glaucoma implant and associated extraocular muscle imbalance. Ophthalmology. 1993;100:914–8.

    Article  CAS  PubMed  Google Scholar 

  7. Topouzis F, Yu F, Coleman AL. Factors associated with elevated rates of adverse outcome after cyclodestructive procedures versus drainage device procedures. Ophthalmology. 1998;105:2276–81.

    Article  CAS  PubMed  Google Scholar 

  8. Singh D. Conjunctiva lymphatic system. J Cataract Refract Surg. 2003;29:632–3.

    Article  PubMed  Google Scholar 

  9. Yucel YH, Johnston MG, Ly T, et al. Identification of lymphatics in the ciliary body of the human eye: a novel “uveolymphatic” outflow pathway. Exp Eye Res. 2009;89:810–9.

    Article  PubMed  Google Scholar 

  10. Yu D-Y, et al. The critical role of the conjunctiva in glaucoma filtration surgery. Prog Retin Eye Res. 2009;28:303–28.

    Article  CAS  PubMed  Google Scholar 

  11. Schmid-Schonbein GW. Microlymphatics and lymph flow. Physiol Rev. 1990;70:987–1028.

    CAS  PubMed  Google Scholar 

  12. Singh M, Aung T, Tun TA, et al. Quantitative analysis of the change in bleb morphology over time after successful trabeculectomy [abstract]. Invest Ophthalmol Vis Sci. 2009;50:E-abstract 3370.

    Google Scholar 

  13. Theelen T, et al. A pilot study on slit lamp-adapted optical coherence tomography imaging of trabeculectomy filtering blebs. Graefes Arch Clin Exp Ophthalmol. 2007;245:877–82.

    Article  PubMed  Google Scholar 

  14. Addicks EM, Quigley HA, Green WR, et al. Histologic characteristics of filtering blebs in glaucomatous eyes. Arch Ophthalmol. 1983;101:795–8.

    Article  CAS  PubMed  Google Scholar 

  15. Labbé A, Dupas B, Hamard P, Baudouin C. In vivo confocal microscopy study of blebs after filtering surgery. Ophthalmology. 2005;112:1979–86.

    Article  PubMed  Google Scholar 

  16. Guthoff R, Klink T, Schlunck G, Grehn F. In vivo confocal microscopy of failing and functioning filtering blebs: results and clinical correlations. J Glaucoma. 2006;15:552–8.

    Article  PubMed  Google Scholar 

  17. Messer EM, Zapp DM, Mackert MJ, et al. In vivo confocal microscopy of filtering blebs after trabeculectomy. Arch Ophthalmol. 2006;124:1095–103.

    Article  Google Scholar 

  18. Schmitt JM, Knüttel K, Yadlowsky M, Eckhaus MA. Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering. Phys Med Biol. 1994;39:1705–20.

    Article  CAS  PubMed  Google Scholar 

  19. Picht G, Grehn F. Sickekissenentwicklung nach trabekulektomien. Ophthalmologe. 1998;95:380–7.

    Article  Google Scholar 

  20. Singh M, Chew PTK, Friedman DS, et al. Imaging of trabeculectomy blebs using anterior segment optical coherence tomography. Ophthalmology. 2007;114:47–53.

    Article  PubMed  Google Scholar 

  21. Teng CC, Chi HH, Katzin HM. Histology and mechanism of filtering operations. Am J Ophthalmol. 1959;47:16–33.

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Vanessa I. Vera MD .

Editor information

Editors and Affiliations

Electronic supplementary material

Below is the link to the electronic supplementary material.

New animation (MOV 19646 kb)

Life surgical procedure (MOV 77170 kb)

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer Science+Business Media New York

About this chapter

Cite this chapter

Vera, V.I., Horvath, C. (2014). XEN Gel Stent: The Solution Designed by AqueSys®. In: Samples, J.R., Ahmed, I.I.K. (eds) Surgical Innovations in Glaucoma. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-8348-9_17

Download citation

  • DOI: https://doi.org/10.1007/978-1-4614-8348-9_17

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4614-8347-2

  • Online ISBN: 978-1-4614-8348-9

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics