Advertisement

Journal of the Korean Physical Society

, Volume 73, Issue 1, pp 60–64 | Cite as

PDMS-based Screw-wall Microfluidic Channel Forming a Turbulent Flow at Low Reynold Number

  • Jun-Min Kim
  • Jaekwan Lim
  • Tae-Rin Lee
  • Sangyoon Park
Article
  • 28 Downloads

Abstract

A mixture of reactants in a PDMS(Polydimethylsiloxane)-based microfluidic channel is a very important factor. A mixture of the fluid in a microfluidic channel is frequently achieved by using some special structure such as grooves or form by inducing a high rate flow that results in a high Reynold number (over 24943 ≫ 2000). However, these methods are accompanied by a complicated procedure like lithography or a special attachment protocol between PDMS and glass. In this study, we introduce a PDMS-based screw-wall microfluidic channel (SMC) as a functionalized channel. The SMC can be developed using a simple protocol and skipping some complicated procedures. Nevertheless, a turbulent flow showing the same mixing performance at low flow rate can be formed. The turbulent flow in the SMC is supported by a computational simulation and is observed by using a mixture of red ink and blue ink under a microscope. Furthermore, its effectiveness for commercial application is confirmed with the synthesis of nanoparticles. The dispersion coefficient (DR) is suggested in a computational simulation and is calculated for three different ratios of the screw thread diameter to the pipe line diameter. This shows that the more effective the mixture by turbulent flow in the SMC is, the nearer to 1 the ratio is. In experiments, a comparison study of a SMC and a plain wall microchannel shows clear differences in the mixtures performance. Finally, nanoparticles are synthesized for 5 different SMCs with pipe line diameters of 120, 170, 200, 500, and 1000 um and a single-peaked distribution for the sizes of the nanoparticles is observed when a 120 um SMC is applied. These results prove that the SMC developed by using our suggesting simple protocol can form a turbulent flow at low flow rate and is good enough to be used as a mixer.

Keywords

PDMS Microfluidics Turbulent flow Screw thread Mixer 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. [1]
    C. L. Chiang, C. S. Sung, T. F. Wu, C. Y. Chen and C. Y. Hsu, J. Chromatogr B Analyt. Technol. Biomed. Life Sci. 822, 1 (2005).CrossRefGoogle Scholar
  2. [2]
    B. J. Zheng, D. Tice, L. S. Roach and R. F. Ismagilov, Angew Chem. Int. Ed. Engl. 43, 19 (2004).Google Scholar
  3. [3]
    L. H. Hung, K. M. Choi, W. Y. Tseng, Y. C. Tan, K. J. Shea and A. P. Lee, Lab Chip 6, 2 (2006).CrossRefGoogle Scholar
  4. [4]
    Y. Song, J. Hormes and C. S. Kumar, Small 4, 6 (2008).CrossRefGoogle Scholar
  5. [5]
    K. S. Elvira, X. C. Solvas and R. C. Wootton, Nat. Chem. 5, 11 (2013).CrossRefGoogle Scholar
  6. [6]
    K. Jain, C. Wu, S. V. Atre, G. Jovanovic, V. Narayanan, S. Kimura, V. Sprenkle, N. Canfield and S. Roy, NSTI Nanotech. Technical Proceedings 3, 391 (2007).Google Scholar
  7. [7]
    X. Z. Lin, A. D. Terepka and H. Yang, Nano Lett. 4, 11 (2004).ADSCrossRefGoogle Scholar
  8. [8]
    S. Y. Yang, F. Y. Cheng, C. S. Yeh and G. B. Lee, Microfluid Nanofluidics 8, 3 (2010).Google Scholar
  9. [9]
    V. S. Cabeza, S. Kuhn, A. A. Kulkarni and K. F. Jensen, Langmuir 28, 17 (2012).CrossRefGoogle Scholar
  10. [10]
    I. Shestopalov, J. D. Tice and R. F. Ismagilov, Lab Chip 4, 4 (2004).CrossRefGoogle Scholar
  11. [11]
    J. BurmáKyong and E. Kyuá Lee, Analyst 130, 7 (2005).Google Scholar
  12. [12]
    L. H. Hung, K. M. Choi, W. Y. Tseng, Y. C. Tan, K. J. Shea and A. P. Lee, Lab Chip 6, 2 (2006).CrossRefGoogle Scholar
  13. [13]
    R. Karnik, F. Gu, P. Basto, C. Cannizzaro, L. Dean, W. Kyei-Manu, R. Langer and O. C. Farokhzad, Nano Lett. 8, 9 (2008).Google Scholar
  14. [14]
    Q. Zhang, J. J. Xu, Y. Liu and H. Y. Chen, Lab Chip 8, 2 (2008).CrossRefGoogle Scholar
  15. [15]
    S. Marre and K. F. Jensen, Chem. Soc. Rev. 39, 3 (2010).CrossRefGoogle Scholar
  16. [16]
    D. Liu, S. Cito, Y. Zhang, C. F. Wang, T. M. Sikanen and H. A. Santos, Adv. Mater. 27, 14 (2015).Google Scholar
  17. [17]
    B. Yu, X. Sun, X. Liu, H. Cong, Y. Wang, X. Shu, H. Yuan, D. Wang and J. Tang, Sci. Adv. Mater. 7, 5 (2015).Google Scholar
  18. [18]
    J. B. You, K. I. Min, B. Lee, D. P. Kim and S. G. Im, Lab Chip 13, 7 (2013).CrossRefGoogle Scholar
  19. [19]
    J. B. You, K. Kang, T. T. Tran, H. Park, W. R. Hwang, J. M. Kim and S. G. Im, Lab Chip 15, 7 (2015).CrossRefGoogle Scholar

Copyright information

© The Korean Physical Society 2018

Authors and Affiliations

  1. 1.Medical Device Research Center Medical & Health Device DivisionKorea Testing LaboratorySeoulKorea
  2. 2.Advanced Institutes of Convergence TechnologySeoul National UniversitySuwonKorea

Personalised recommendations