Russian Electrical Engineering

, Volume 84, Issue 10, pp 586–590 | Cite as

The effect of the operating regime of 6(10)-kV power cables on parameters of partial discharges in insulation

  • A. V. Korzhov
  • A. A. Kozin
Article
  • 45 Downloads

Abstract

The effect of the operating regime of 6(10)-kV power cables of urban power-distribution networks on the parameters of partial discharges in insulation is investigated. Operating regimes of the cable, regimes after high-voltage testing and short circuits, and the ability to diagnose a single-phase fault in an urban 6(10)-kV power-distribution network are analyzed. Dependences of changes in partial discharge intensity in these regimes are defined.

Keywords

6(10)-kV power cable operating regime insulation partial discharges 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Korzhov, A.V., How electric and magnetic fields of power cable lines of 6(10)kV voltage influence onto partial discharges intensity in insulation under different modes of operation, in Kabeli i provoda (Cables and Wires), Moscow, 2012, issue 1(332), pp. 16–21.Google Scholar
  2. 2.
    Korzhov, A.V. and Sidorov, A.I., Metody i modeli otsenki sostoyaniya izolyatsii i elektrobezopasnosti kabel’nykh linii 6 (10) kV gorodskikh elektricheskikh setei (Methods and Models for Estimating Insulation State and Electrical Safety of 6(10) kV Cable Lines for City Electrical Networks), Chelyabinsk: Izd. tsentr Yuzh.-Ural. Gos. Univ., 2009.Google Scholar
  3. 3.
    Korzhov, A.V., How magnetic component of electromagnetic field influences onto partial discharges intensity in cables with paper impregated and polyethylened isolation, in Kabeli i Provoda (Cables and Wires), Moscow, 2012, issue 6(337), pp. 10–15.Google Scholar
  4. 4.
    Korzhov, A.V., The way to choose relay protection settings and zone automated repeated switching in 6 (10) kV cable network for isolation resource-saving and for improving working conditions, in Promyshlennaya energetika (Industrial Electric Engineering), Moscow, 2013, issue 2, pp. 10–16.Google Scholar
  5. 5.
    Izmerenie chastichnykh razryadov v izolyatsii vysokovol’tnogo oborudovaniya. Metodicheskoe posobie (The Way to Measure Partial Discharges in High Voltage Equipment Isolation. Guide Book), Perm: Vibro-Tsentr, 2009. http://www.dimrus.ru; http://www.vibrocenler.ru
  6. 6.
    Kuchinskii, G.S., Chastichnye razryady v vysokovol’tnykh konstruktsiyakh (Partial Discharges in High-Voltage Structures), Leningrad: Energiya, 1979.Google Scholar

Copyright information

© Allerton Press, Inc. 2013

Authors and Affiliations

  • A. V. Korzhov
  • A. A. Kozin

There are no affiliations available

Personalised recommendations