Abstract
Increasing dose for improved radiotherapy efficiency is essential for linear accelerator development and also for flattening filter geometry and material enhancement. Determination and understanding the photon beam properties using material and geometry of a beam modifier is very important in radiotherapy department and also for high patient life quality. This Monte Carlo study aims to improve the FF in a linac for increasing the photon number at the entrance of treatment volume tumor and the dose delivered inside the treatment volume as recommended by the IAEA protocols. The aim of this study was to check out the possibility to reduce the flattening filter volume for improving the clinical photons at phantom surface. We have studied photon attenuation coefficients and beam softening coefficients with FF volume reduction. The FF volume was reduced by 10, 20, and 30% of initial FF volume. The photon fluence increased with FF volume reduction near the beam central axis than the beam edge and the beam softening coefficients remained apparently invariable with FF volume reduction as a function of off-axis distance. Our work can be a basic study that will be used in research and improvement for future linac configuration in terms of photon attenuation and beam softening for a material, geometry and volume that were used for finding out good flattening and good softening to produce an optimal delivered dose as recommended by IAEA.
Similar content being viewed by others
References
M. Bencheikh, A. Maghnouj, and T. Tajmouati, “Photon beam softening coefficients evaluation for a 6 MeV photon beam for an aluminum slab: Monte Carlo study using BEAMnrc code, DOSXYZnrc code and BEAMDP code,” Moscow Univ. Phys. Bull. 72, 263–270 (2017).
THERAPLAN Plus Technical Reference Manual, 18th ed. (MDS Nordion, Canada, 2000).
M. Yu, R. Sloboda, and B. Murray, “Linear accelerator photon beam quality at off-axis points,” Med. Phys. 24, 233–239 (1997).
M. Bencheikh, A. Maghnouj, and J. Tajmouati, “Energetic properties’ investigation of removing flattening filter at phantom surface: Monte Carlo study using BEAMnrc code, DOSXYZnrc code and BEAMDP code,” Phys. Part. Nucl. Lett. 14, 953–962 (2017).
A. Didi, A. Dadouch, M. Bencheikh, and O. Jai, “Monte Carlo simulation of thermal neutron flux of americium–beryllium source used in neutron activation analysis,” Moscow Univ. Phys. Bull. 72, 460–464 (2017)
A. Didi, A. Dadouch and H. El Bekkouri, “Feasibility study for production of iodine-131 using dioxide of tellurium-130,” Int. J. Pharm. Pharm. Sci. 8, 327–331 (2016)
D. W. O. Rogers, B. Walters, and I. Kawrakow, BEAMnrc Users Manual, NRCC Report (Ottawa, 2013), pp. 12–254.
D. W. O. Rogers, I. Kawrakow, J. P. Seuntjens, B. Walters, and H. E. Mainegra, NRC User Codes for EGSnrc (Ottawa, 2013), pp. 6–83.
M. Bencheikh, A. Maghnouj, J. Tajmouati, A. Didi, and A. O. Ezzati, “Validation of Monte Carlo simulation of linear accelerator using BEAMnrc code and DOSXYZnrc code,” Phys. Part. Nucl. Lett. 14, 780–787 (2017).
Commissioning and Quality Assurance of Computerized Planning Systems for Radiation Treatment of Cancer (International Atomic Energy Agency, Vienna, 2004).
Specification and Acceptance Testing of Radiotherapy Treatment Planning Systems (International Atomic Energy Agency, Vienna, 2007).
M. Aljamal and A. Zakaria, “Monte Carlo modeling of a Siemens Primus 6 MeV photon beam linear accelerator,” Aust. J. Basic Appl. Sci. 7, 340–346 (2013).
C. M. Ma and D. W. O. Rogers, BEAMDP Users Manual, (National Research Council of Canada, Ottawa, 2013), pp. 3–24.
M. Muhammad, M. Wazir, S. Muhammad, A. Misbah, and M. Matiullah, “Accuracy checks of physical beam modifier factors algorithm used in computerized treatment planning system for a 15 MeV photon beam, Rep. Pract. Oncol. Radiother. 14 14, 214–220 (2010).
M. Bencheikh, A. Maghnouj, and J. Tajmouati, “Photon beam softening coefficient determination with slab thickness in small filed size: Monte Carlo study,” Phys. Part. Nucl. Lett. 14, 963–970 (2017)
P. Lonski, M. L. Taylor, R. D. Franich, P. Harty, and T. Kron, “Assessment of leakage doses around the treatment heads of different linear accelerators,” Radiat. Prot. Dosim. 152, 304–312 (2012).
Absorbed Dose Determination in External Beam Radiotherapy (International Atomic Energy Agency, Vienna, 2000), No. 398, pp. 110–133.
Author information
Authors and Affiliations
Corresponding author
Additional information
The article is published in the original.
About this article
Cite this article
Bencheikh, M., Maghnouj, A., Tajmouati, J. et al. Study of Possibility to Reduce Flattening Filter Volume for Increasing Energetic Photons for High Radiotherapy Efficiency. Moscow Univ. Phys. 72, 653–657 (2017). https://doi.org/10.3103/S0027134918660049
Received:
Published:
Issue Date:
DOI: https://doi.org/10.3103/S0027134918660049