Abstract
Values of the thermal-conductivity coefficient of specimens of the frame insulation manufactured from pre- and unimpregnated, mica-containing tapes are determined. It is established that the tape structure, temperature, epoxy binding content, and type of packing materials (filling compounds) have an effect on the thermal conductivity of the insulation system of the stator winding of turbogenerators with air cooling.
Similar content being viewed by others
References
Marek, P. et al., High Performance Insulation Systems for HV Rotating Machines, Proc. 10th Insucon Int. Conf., 2006, pp. 283–288.
Tari, M. et al., The System of High-Voltage Insulation Intended for Turbogenerators with Increased Thermal Conductivity, Tr. IV Mezhd. simposiuma Elmash (Proc. IV Int. Symp. Elmash), Moscow, 2002, pp. 102–104.
Fukushima, K. et al., High Thermal Conductive Epoxy Resins with Controlled High Order Structure, Annual Report Conf. on Elec. Insul. and Diel. Phenom., 2004, pp. 340–343.
Additional information
Original Russian Text © A.Sh. Azizov, A.M. Andreev, A.M. Kostel’ov, Yu.I. Polikarpov, 2009, published in Elektrotekhnika, 2009, No. 3, pp. 10–14.
About this article
Cite this article
Azizov, A.S., Andreev, A.M., Kostel’ov, A.M. et al. Thermal conductivity of the insulation system of the stator winding of a high-power turbogenerator with air cooling. Russ. Electr. Engin. 80, 128–131 (2009). https://doi.org/10.3103/S106837120903002X
Published:
Issue Date:
DOI: https://doi.org/10.3103/S106837120903002X