Comparison of Electron Beam Scattering at Edges of 3D-Printed Plastic and Metal Collimators

  • A. A. Krasnykh
  • Yu. M. Cherepennikov
  • S. G. Stuchebrov
  • I. A. Miloichikova
  • B. M. Gavrikov
  • D. A. Belousov
  • M. A. KazaryanEmail author
Article
  • 2 Downloads

Abstract

Dose distributions of 6-MeV electrons in the region of edges of metal and plastic collimators are compared using calculated and experimental data. The results of the study show an insignificant disagreement in the dose distributions: the difference in the penumbra widths does not exceed 1.1 mm.

Keywords

electron beam collimator numerical simulation clinical linear accelerator dose distribution 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Notes

Acknowledgments

This study was supported by the Russian Science Foundation, project no. 18-79-10052.

References

  1. 1.
    Yu. A. Bashmakov, T. V. Bondarenko, and S. M. Polozov, Kjatkie Soobshcheniya po Fizike FIAN 43(2), 138 (2016) [Bulletin of the Lebedev Physics Institute 43, 59(2016)].Google Scholar
  2. 2.
    C. Garibaldi, B. A. Jereczek-Fossa, G. Marvaso et at, Ecancermedicalscience 11(785), 19 (2017).Google Scholar
  3. 3.
    V. V. Siksin and Yu. P. Endovin, Kratkie Soobshcheniya po Fizike FIAN 45(6), 42 (2018) [Bulletin of the Lebedev Physics Institute 45, 190 (2018)].Google Scholar
  4. 4.
    “Workstation for Melting and Casting Alloy,” http://www.parscientific.com/Workstation.html.
  5. 5.
    I. A. Miloichikova, A. A. Krasnykh, I. B. Danilova et al., AIP Conf. Proc. 1772(1), 060018 (2016).CrossRefGoogle Scholar
  6. 6.
    Computer Laboratory (PCLab). Certificate of Official Registration of the Computer Program no. 2007615275, 28.12.2007.Google Scholar
  7. 7.
    ONCOR Digital Medical Linear Accelerator Specifications, http://www.siemens.com.tr/i/assets/saglik/onkoloji/oncor.pdf.
  8. 8.
    P. Sipilä, J. Ojala, S. Kaijaluoto, et al., J. Appl. Clin. Med. Phys. 17, 360 (2016).CrossRefGoogle Scholar

Copyright information

© Allerton Press, Inc. 2019

Authors and Affiliations

  • A. A. Krasnykh
    • 1
  • Yu. M. Cherepennikov
    • 1
  • S. G. Stuchebrov
    • 1
  • I. A. Miloichikova
    • 1
    • 2
  • B. M. Gavrikov
    • 3
  • D. A. Belousov
    • 4
  • M. A. Kazaryan
    • 5
    Email author
  1. 1.National research Tomsk Polytechnic UniversityTomskRussia
  2. 2.Tomsk Cancer Research Institute, Tomsk National Research Medical CenterRussian Academy of Medical SciencesTomskRussia
  3. 3.Moscow Municipal Oncological Hospital no. 62Moscow regionRussia
  4. 4.Institute of Automation and ElectrometrySiberian Branch of the Russian Academy of ScienceNovosibirskRussia
  5. 5.Lebedev Physical InstituteRussian Academy of SciencesMoscowRussia

Personalised recommendations