Abstract
A piece of fused-silica fibre coated with silica modified with ketamine-groups was used as a solidphase microextraction (SPME) fibre and its efficiency in the qualitative and quantitative analysis of volatile organic compounds released from coloured overprinting on DVDs was evaluated. The effect of the parameters that can affect the SPME procedure, such as extraction time, extraction temperature, desorption temperature, was investigated to determine the analytical performance of this novel fibre in the qualitative and quantitative analyses of organic compounds. The optimised procedure was applied to the qualitative and quantitative analyses of organic compounds released from coloured overprinting on DVDs. The limit of detection of 4-methoxyphenol (mequinol) was 88 × 10−3 μg mL−1, while the limit of quantification (LOQ) was calculated as ten times the baseline noise, i.e. 3.1 × 10−1 μg mL−1. The proposed fibre was used successfully for preconcentration of the volatile organic compounds from the gaseous phase of DVD samples.
Similar content being viewed by others
References
Arthur, C. L.,& Pawliszyn, J. (1990). Solid phase microextraction with thermal desorption using fused silica optical fibres. Analytical Chemistry, 62, 2145–2148. DOI:10.1021/ac00218a019.
da Silveira, C. B., de Oliveira, A. F., de Campos, S. D., de Campos, É. A., & Carasek, E. (2005). Glass fibres coated with Nb2O5 for use in SPME. Colloids and Surfaces A: Physicochemistry and Engineering Aspects, 259, 15–22. DOI:10.1016/j.colsurfa.2004.12.065.
de Souza, M. M., Bortoluzzi, J. H., & Carasek, E. (2006). Thermal immobilization of poly(butylacrylate) on glass-ceramic rod for preparation of solid phase microextraction fibres. Microchim Acta, 155, 465–469. DOI: 10.1007/s00604-006-0582-1.
Djozan, Dj.,& Assadi, Y. (2004). Modified pencil lead as a new fibre for solid-phase microextraction. Chromatographia, 60, 313–317. DOI: 10.1365/s10337-004-0368-8.
Farajzadeh, M. A.,& Matin, A. A. (2008). Determination of BTEX in water samples with an SPME hollow fibre coated copper wire. Chromatographia, 68, 443–446. DOI:10.1365/s10337-008-0726-z.
Gierak, A., Seredych, M.,& Bartnicki, A. (2006). The preparation, properties and application of carbon fibre for SPME. Talanta, 69, 1079–1087. DOI: 10.1016/j.talanta.2005.12.025.
Hawthorne, S. B., Miller, D. J., Pawliszyn, J.,& Arthur, C. L. (1992). Solventless determination of caffeine in beverages using solid-phase microextraction with fused-silica fibres. Journal of Chromatography A, 603, 185–191. DOI: 10.1016/0021-9673(92)85360-6.
Pawliszyn, J. (1997). Solid phase microextraction: Theory and practice. New York, NY, USA: Wiley-VCH.
Rykowska, I., Wasiak, W.,& Byra, J. (2008). Extraction of copper ions using silica gel with chemically modified surface. Chemical Papers, 28, 255–259. DOI: 10.2478/s11696-008-0020-4.
Sun, T. H., Cao, L. K.,& Jia, J. P. (2005). Novel activated carbon fibre solid-phase microextraction for determination of benzyl chloride and related compounds in water by gas chromatography-mass spectrometry. Chromatographia, 61, 173–179. DOI: 10.1365/s10337-004-0481-8.
Wan, H. B., Chi, H., Wong, M. K.,& Mok, C. Y. (1994). Solidphase microextraction using pencil lead as sorbent for analysis of organic pollutants in water. Analytica Chimica Acta, 298, 219–223. DOI: 10.1016/0003-2670(94)00270-3.
Wang, S., Wang, Y., You, H.,& Yao, J. (2006). Preparation of a carbon-coated SPME fibre and application to the analysis of BTEX and halocarbons in water. Chromatographia, 63, 365–371. DOI: 10.1365/s10337-006-0750-9.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Palacz, M., Wasiak, W. New SPME fibre for analysis of mequinol emitted from DVDs. Chem. Pap. 65, 113–118 (2011). https://doi.org/10.2478/s11696-011-0006-5
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2478/s11696-011-0006-5