Simultaneous spectrophotometric determination of minoxidil and tretinoin by the H-point standard addition method and partial least squares

  • Original Paper
  • Published:
Chemical Papers Aims and scope Submit manuscript

Abstract

A simple, sensitive and selective spectrophotometric method for simultaneous determination of tretinoin and minoxidil using partial least square (PLS) calibration and H-point standard addition method (HPSAM) is described. The results of the H-point standard addition method show that minoxidil and tretinoin can be determined simultaneously with the concentration ratio of tretinoin to minoxidil varying from 2: 1 to 1: 33 in mixed samples. A partial least squares multivariate calibration method for the analysis of binary mixtures of tretinoin and minoxidil was also developed. The total relative standard error for applying the PLS method to eleven synthetic samples in the concentration range of 0–10 μg mL−1 tretinoin and 0–32 μg mL−1 minoxidil was 2.59 %. Both proposed methods (PLS and HPSAM) were also successfully applied in the determination of tretinoin and minoxidil in several synthetic pharmaceutical solutions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Amankwa, L., Chatten, L. G., & Pons, S. (1983). Electrochemical studies on minoxidil and its determination in tablets by differential-pulse polarography. Analyst, 108, 1221–1226. DOI: 10.1039/AN9941902123.

    Article  CAS  Google Scholar 

  • Arcos, J., García, B., Munguia, A., & López Palacios, J. (1991). Spectrophotometric and electroanalytical study of minoxidil. Analytical Letters, 24, 357–376. DOI: 10.1080/00032719108 052912.

    CAS  Google Scholar 

  • Blanco, M., Coello, J., Ituriaga, H., Maspoch, S., & Redon, M. (1994). Principal component regression for mixture resolution in control analysis by UV-Visible spectrophotometry. Applied Spectroscopy, 48, 37–43. DOI: 10.1366/0003702944027633.

    Article  CAS  Google Scholar 

  • Bosch-Reig, F., & Campíns-Falcó, P. (1988). H-point standard additions method. Part 1. Fundamentals and application to analytical spectroscopy. Analyst, 113, 1011–1016. DOI: 10.1039/AN9881301011.

    Article  Google Scholar 

  • Bosch-Reig, F., Campíns-Falcó, P., Sevillano-Cabeza, A., Herráez-Hernández, B., & Molins-Legua, C. (1991). Development of the H-point standard-additions method for ultraviolet-visible spectroscopic kinetic analysis of two-component systems. Analytical Chemistry, 63, 2424–2429. DOI: 10.1021/ac00021a008.

    Article  CAS  Google Scholar 

  • Bosch-Reig, F., Campíns-Falcó, P., & Verdú-Andrés, J. (1992a). Application of the H-point standard additions method by using absorbance increment values as analytical signals. Talanta, 39, 1–7. DOI: 10.1016/0039-9140(92)80042-C.

    Article  Google Scholar 

  • Bosch-Reig, F., Campíns-Falcó, P., Herráez-Hernández, B., & Sevillano-Cabeza, A. (1992b). Development of the H-point standard additions method for coupled liquid chromatography and UV-visible spectrophotometry. Analytica Chimica Acta, 257, 89–98. DOI: 10.1016/0003-2670(92)80154-Y.

    Article  Google Scholar 

  • Bosch-Reig, F., Campíns-Falcó, P., & Verdú-Andrés, J. (1992c). Evaluation and elimination of the “blank bias error” using the H-point standard addition method: Application to spectrophotometric determinations using absorbent blank. Analytica Chimica Acta, 270, 253–265. DOI: 10.1016/0003-2670(92)80115-N.

    Article  Google Scholar 

  • Bosch-Reig, F., Campíns-Falcó, P., & Verdú-Andrés, J. (1993). Development of the H-point standard additions method for analyte determinations in unknown matrix: Location of linear matrix spectral interval. Analytica Chimica Acta, 283, 831–844. DOI: 10.1016/0003-2670(93)85297-W.

    Article  CAS  Google Scholar 

  • Bosch-Reig, F., Campíns-Falcó, P., Verdú-Andrés, J., & Molins-Legua, C. (1994a). Study of the behaviour of the absorbent blanks in analytical procedures by using the H-Point standard additions method (HPSAM). Talanta, 41, 39–52. DOI: 10.1016/0039-9140(94)80166-5.

    Article  CAS  Google Scholar 

  • Bosch-Reig, F., Campíns-Falcó, P., Sevillano-Cabeza, A., & Molins-Legua, C. (1994b). Determination of amphetamine and methamphetamine in urine with sodium 1,2 naphthoquinone 4-sulphonate using the H-point standard addition method. Analytica Chimica Acta, 287, 41–48. DOI: 10.1016/0003-2670(94)85099-2.

    Article  Google Scholar 

  • Bosch-Reig, F., Campíns-Falcó, P., & Verdú-Andrés, J. (1994c). Development of the H-point standard additions method for the use of spectrofluorimetry and synchronous spectrofluorimetry. Analyst, 119, 2123–2127. DOI: 10.1039/AN9941902123.

    Article  Google Scholar 

  • Bosch-Reig, F., Campíns-Falcó, P., Sevillano-Cabeza, A., & Molins-Legua, C. (1995). Generalized H-point standard additions method for analyte determinations in unknown samples. Analytica Chimica Acta, 302, 323–333. DOI: 10.1016/0003-2670(94)00496-9.

    Article  Google Scholar 

  • Boyd, A. S. (1989). An overview of the retinoids. The American Journal of Medicine, 86, 568–574. DOI: 10.1016/0002-9343(89)90386-0.

    Article  CAS  Google Scholar 

  • Brown, S. D., Barker, T. Q., Lerivee, R. J., Monfre, S. L., & Wilk, H. R. (1988). Chemometrics. Analytical Chemistry, 60, 252R–273R. DOI: 10.1021/ac00163a018.

    Article  CAS  Google Scholar 

  • Campíns-Falcó, P., Blasco Gómez, F. & Bosch-Reig, F. (1998). The H-point and generalized H-point standard additions methods for flow injection procedures. Talanta, 47, 193–202. DOI: 10.1016/S0039-9140(98)00067-8.

    Article  Google Scholar 

  • Chen, Y.-C., Luo, D., & Tang, X.-Z. (2000). Determination of two components in compound minoxidil liniment by UV spectrophotometry. West China Journal of Pharmaceutical Sciences, 15, 62–63.

    CAS  Google Scholar 

  • Despagne, F., Masart, D., & Noord, C. E. (1997). Optimization of partial-least-squares calibration models by simulation of instrumental perturbations. Analytical Chemistry, 69, 3391–3399. DOI: 10.1021/ac970228d.

    Article  CAS  Google Scholar 

  • Fanali, S., Cristalli, M., & Catellani, P. (1987). Determination of minoxidil in pharmaceutical forms by capillary isotachophoresis. Journal of Chromatography A, 405, 385–388. DOI: 10.1016/S0021-9673(01)81781-7.

    Article  CAS  Google Scholar 

  • Ferry, J. J., Forbes, K. K., VanderLugt, J. T., & Szpunar, G. J. (1990). Influence of tretinoin on the percutaneous absorption of minoxidil from an aqueous topical solution. Clinical Pharmacology & Therapeutics, 47, 439–442.

    CAS  Google Scholar 

  • Frank, I. E., Feikema, J., Constantine, N., & Kowalski, B. R. (1984). Prediction of product quality from Spectral data using the partial least-squares method. Journal of Chemical Information and Computer Sciences, 24, 20–24. DOI: 10.1021/ci00041a602.

    Google Scholar 

  • Gaillard, Y., & Pépin, G. (1997). Use of high-performance liquid chromatography with photodiode-array UV detection for the creation of a 600-compound library application to forensic toxicology. Journal of Chromatography A, 763, 149–163. DOI: 10.1016/S0021-9673(96)00706-6.

    Article  CAS  Google Scholar 

  • Geladi, P., & Kowalski, B. R. (1986). Partial least-squares regression: a tutorial. Analytica Chimica Acta, 185, 1–17. DOI: 10.1016/0003-2670(86)80028-9.

    Article  CAS  Google Scholar 

  • Gerlach, R. W., Kowalski, B. R., & Wold, H. (1979). Partial least-squares path modelling with latent variables. Analytica Chimica Acta, 112, 417–421. DOI: 10.1016/S0003-2670(01)85039-X.

    Article  CAS  Google Scholar 

  • Haaland, D. M., & Thomas, E. V. (1988a). Partial least-squares methods for spectral analyses. 1. Relation to other quantitative calibration methods and the extraction of qualitative information. Analytical Chemistry, 60, 1193–1202. DOI: 10.1021/ac00162a020.

    Article  CAS  Google Scholar 

  • Haaland, D. M., & Thomas, E. V. (1988b). Partial least-squares methods for spectral analyses. 2. Application to simulated and glass spectral data. Analytical Chemistry, 60, 1202–1208. DOI: 10.1021/ac00162a021.

    Article  CAS  Google Scholar 

  • Hargis, L. G., & Howell, J. A. (1988). Ultraviolet and light absorption spectrometry. Analytical Chemistry, 60, 131R–146R. DOI: 10.1021/ac00163a010.

    Article  CAS  Google Scholar 

  • Jöreskog, K. G., & Wold, H. O. A. (Eds.) (1982). System under indirect observation: casuality, structure, prediction (pp.110–125). Amsterdam: North Holland Publishing Company.

    Google Scholar 

  • Lauer, A. C. (1999). Percutaneous drug delivery to the hair follicle. In R. L. Bronaugh, and H. I. Maibach (Eds.), Percutaneous absorption, drugs-cosmetics-mechanisms-methodology (3rd ed.) (pp. 427–450). New York: Marcel Dekker, Inc.

    Google Scholar 

  • Lauer, A. C., Lieb, L. M., Ramachandran, C., Flynn, G. L., & Weiner, N. D. (1995). Transfollicular drug delivery. Pharmaceutical Research, 12, 179–186. DOI: 10.1023/A:1016250422596.

    Article  CAS  Google Scholar 

  • Law, N., & Appleby, J. R. G. (1996). Re-evaluation of strong cation-exchange high-performance liquid chromatography for the analysis of basic drugs. Journal of Chromatography A, 725, 335–341. DOI: 10.1016/0021-9673(95)01002-5.

    Article  CAS  Google Scholar 

  • London-Wong, D. M., & Hart, L. L. (1990). Minoxidil with tretinoin in baldness. The Annals of Pharmacotherapy, 24, 43–44.

    CAS  Google Scholar 

  • Mahrous, M. S., Abdel-Khalek, M. M., & Beltagy, Y. A. (1992). Simultaneous quantitation of minoxidil and tretinoin in magistral and pharmaceutical preparations by first derivative spectrophotometry. Analytical Letters, 25, 1673–1686. DOI: 10.1080/00032719208018242.

    CAS  Google Scholar 

  • Otto, M., & Wegscheider, W. (1985). Spectrophotometric multicomponent analysis applied to trace metal determinations. Analytical Chemistry, 57, 63–69. DOI: 10.1021/ac00279a020.

    Article  CAS  Google Scholar 

  • Perez-Bendito, D., & Silva, M. (1998). Kinetic methods in analytical chemistry (pp. 150). Chichester: Ellis Horwood.

    Google Scholar 

  • Rougier, A., & Lotte, C. (1993). Predictive approaches I: The stripping technique. In V. P. Shah, and H. I. Maibach (Eds.), Topical drug bioavailability, bioequivalence and penetration (pp. 163–182). New York: Plenum Press.

    Google Scholar 

  • Royer, M. E., Ko, H., Gilbertson, T. J., McCall, J. M., & Johnston, K. T. (1977). Radioimmunoassay of minoxidil in human serum. Journal of Pharmaceutical Sciences, 66, 1266–1269. DOI: 10.1002/jps.2600660915.

    Article  CAS  Google Scholar 

  • Safavi, A., Abdollahi, H., Sedaghatpour, F., & Zeinali, S. (2000). Kinetic spectrophotometric determination of V(IV) in the presence of V(V) by the H-point standard addition method. Analytica Chimica Acta, 409, 275–282. DOI: 10.1016/S0003-2670(99)00868-5.

    Article  CAS  Google Scholar 

  • Spiegelman, C. H., McShane, M. J., Goetz, M. J., Motamedi, M., Yue, Q. L., & Coté, G. L. (1998). Theoretical justification of wavelength selection in PLS calibration: Development of a new algorithm. Analytical Chemistry, 70, 35–44. DOI: 10.1021/ac9705733.

    Article  CAS  Google Scholar 

  • Tracqui, A., Kintz, P., & Mangin, P. (1995). Systematic toxicological analysis using HPLC/DAD. Journal of Forensic Science, 40, 254–262.

    CAS  Google Scholar 

  • Trotta, M., Ugazio, E., Peira, E., & Pulitano, C. (2003). Influence of ion pairing on topical delivery of retinoic acid from microemulsions. Journal of Controlled Release, 86, 315–321. DOI: 10.1016/S0168-3659(02)00416-9.

    Article  CAS  Google Scholar 

  • Van de Vaart, F. J., Indemans, A. W. M., Hulshoff, A., & Lake, O. A. (1982). The application of chromatography to the analysis of pharmaceutical creams. Chromatographia, 16, 247–250. DOI: 10.1007/BF02258912.

    Article  Google Scholar 

  • Wang, L. H. (2000). Simultaneous determination of retinal, retinol and retinoic acid (all-trans and 13-cis) in cosmetics and pharmaceuticals at electrodeposited metal electrodes. Analytica Chimica Acta, 415, 193–200. DOI: 10.1016/S0003-2670(00)00870-9.

    Article  CAS  Google Scholar 

  • Weiner, N. (1998). Targeted follicular delivery of macromolecules via liposomes. International Journal of Pharmaceutics, 162, 29–38. DOI: 10.1016/S0378-5173(97)00409-2.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Maryam Bordbar.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bordbar, M., Yeganeh-Faal, A., Ghasemi, J. et al. Simultaneous spectrophotometric determination of minoxidil and tretinoin by the H-point standard addition method and partial least squares. Chem. Pap. 63, 336–344 (2009). https://doi.org/10.2478/s11696-009-0003-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2478/s11696-009-0003-0

Keywords

Navigation