Cyclic performance of precast concrete shear walls with a mortar–sleeve connection for longitudinal steel bars

Original Article

Abstract

To study the cyclic performance of precast concrete shear walls with a mortar–sleeve connection for longitudinal steel bars, a quasistatic test on shear wall specimens with flexure failure modes was carried out. The longitudinal steel bars in the precast concrete walls were connected with a steel sleeve using mortar. Test results indicated that the mortar–sleeve splicing effectively transferred the stresses on the vertical steel bars. The failure mode of the precast shear wall specimens had similar behaviors to that of the cast-in-place shear wall specimen, including the tensile yielding of the longitudinal steel bars and the crushing of the concrete in the compressive zone. The stiffness and energy dissipation capacity of the precast wall specimens were less than those of the cast-in-place wall specimen. The ultimate drift ratio of the precast wall specimens ranged from 1.69 to 2.08 %. The integrity of the precast shear walls with a vertical rough interface was better than that of the precast shear walls with a vertical step groove.

Keywords

Precast shear wall Quasistatic test Seismic behavior Mortar–sleeve 

References

  1. 1.
    Xue W, Wang D (2002) Progress of pre-cast concrete slab and wall system. Ind Constr 32(12):57–60Google Scholar
  2. 2.
    Cleland NM (1997) Design for lateral force resistance with pre-cast concrete shear walls. PCI J 5:44–64Google Scholar
  3. 3.
    Basler E (1963) Allgemeine merklnale der vorfabrikation. Teehn. Forsehungsun Reratungsstelle der sehweizerischen Zementindustrie, WildeggGoogle Scholar
  4. 4.
    Englekirk RE (2004) Impact of Northridge earthquake on pre-cast concrete design practice. Struct Des Tall Spec Build 13:457–463CrossRefGoogle Scholar
  5. 5.
    Muguruma H, Nishiyarna M, Watanabe F (1995) Lessons learned from the Kobe earthquake: a Japanese perspective. PCI J 4:28–42CrossRefGoogle Scholar
  6. 6.
    Arditi D, Ergin U, Gunhan S (2000) Factors affecting the use of pre-cast concrete systems. J Archit Eng 3:79–86CrossRefGoogle Scholar
  7. 7.
    Cleland NM (1997) Design for lateral force resistance with pre-cast concrete shear walls. PCI J 5:44–64Google Scholar
  8. 8.
    Sun J (1986) Behavior of the reinforcement in pre-cast structures. Beijing Institute of Architecture DesignGoogle Scholar
  9. 9.
    Rizkalla SH, Serrette RL, Heuvel JS (1989) Multiple shear key connections for pre-cast shear wall panels. PCI J 1:104–119CrossRefGoogle Scholar
  10. 10.
    Schultz AE, Magana RA, Tadros MK, Huo X (1994) Experimental study of joint connections in pre-cast concrete walls. Fifth U.S. national conference on earthquake engineering, vol II, 10–14 July 1994Google Scholar
  11. 11.
    Soudki KA, Rizkalla SH (1995) Horizontal connection for pre-cast concrete shear walls subjected to cyclic deformations. PCI J 4:78–96CrossRefGoogle Scholar
  12. 12.
    Priestley MJN, MacRae GA (1996) Seismic tests of pre-cast beam-to-column joint subassemblages with unbounded tendons. PCI J 41(1):64–81CrossRefGoogle Scholar
  13. 13.
    Perez FDJ (1998) Lateral load behavior and design of unbonded post-tensioned pre-cast concrete walls with ductile vertical joint connectors. Theses and Dissertations, Paper 567Google Scholar
  14. 14.
    PCI Connection Details Committee (2008) PCI connections manual for pre-cast and prestressed concrete construction, 1st edn. PCI, ChicagoGoogle Scholar
  15. 15.
    Belleri A, Riva P (2012) Seismic performance and retrofit of pre-cast concrete grouted sleeve connections. PCI J 57(1):97–109CrossRefGoogle Scholar
  16. 16.
    Aslam M, Goddon WG, Scalise DT (1980) Earthquake rocking response of rigid bodies. J Struct Div ASCE 106(2):377–392Google Scholar
  17. 17.
    Housner GW (1963) The behavior of inverted pendulum structures during earthquake. Bull Seismol Soc Am 53(2):403–417Google Scholar
  18. 18.
    Kurama Y, Sause R, Pessiki S, Lu LW, El-Sheikh M (1998) Seismic design and response evaluation of un-bonded post-tensioned pre-cast concrete walls. Pre-cast Seismic Structural Systems (PRESSS), Rep. No. 98(03) Lehigh Univ., Lehigh, Pa., Rep. No. EQ-97-01Google Scholar
  19. 19.
    Boroschek RL, Yáñez FV (2000) Experimental verification of basic analytical assumptions used in the analysis of structural wall buildings. Eng Struct 22(6):657–669CrossRefGoogle Scholar
  20. 20.
    Mitchell D, Cook W, Deng Y, Liu J (2014) Confinement of columns and wall boundary elements using headed bars. J Struct Eng 140(3):04013080CrossRefGoogle Scholar

Copyright information

© RILEM 2015

Authors and Affiliations

  1. 1.School of Civil EngineeringChongqing UniversityChongqingChina
  2. 2.Chongqing Architecture Design InstituteChongqingChina
  3. 3.Department of Civil EngineeringTsinghua UniversityBeijingChina

Personalised recommendations