Abstract
Direct real-time observations of electromigration (EM) in submicron Al interconnects were made using a special sample-stage which allowed TEM observations to be recorded while simultaneously heating and passing current through the sample. The samples consisted of 4000Å thick Al(0.5wt%Cu) patterned over a TEM-transparent window into five runners in parallel, with linewidths 0.2, 0.3, 0.5, 0.8, and 1.0μm. Both passivated and unpassivated samples were examined. A current density of 2 x 106A/cm2 was used with temperatures ranging from 200 - 350°C. The experiments were done using constant voltage testing, and we used a special sample design which dramatically minimized Joule-heating. Our approach has allowed us to directly observe voids form, grow, migrate, pin, fail a runner, and heal, all with respect to the detailed local microstructure of the runners.
This is a preview of subscription content, access via your institution.
References
- 1
R. Kirchheim, Mat. Res. Soc. Symp. Proc., ed. by K.P Rodbell, W.F. Filter, H.J. Frost, and P.S. Ho, 309, 1993, p. 101.
- 2
M.A. Korhonen et al., AIP Conference Proc., 305, Stress Induced Phenomena in Metallization, ed. P.S. Ho, C.Y. Li, P. Totta, p. 15, 1993.
- 3
H.J Frost and C.V. Thompson, Ibid, p. 254.
- 4
Previous in-situ methods have examined much wider runners, e.g.: I. A. Blech and E.S. Meieran, J. Appl. Phys., 40, 485 (1969). High-voltage SEM methods have also been used: T.N. Marieb et al, AIP Conference Proc., 305, Stress Induced Phenomena in Metallization, ed. P.S. Ho, C.Y. Li, P. Totta, p. 1, 1993.
- 5
Note on Figures 3-7: these micrographs were obtained by “frame-grabbing” from a video tape. A slight defect in the oil-immersion lens of the camera produced a line near the middle-to-right hand side of each micrograph.
- 6
J.E. Sanchez, O. Kraft, and E. Arzt, Appl. Phys. Lett., 61, 3121 (1992).
- 7
S.P. Riege, A.W. Hunt, and J.A. Prybyla, in progress, to be submitted to J. Appl. Phys.
- 8
A.W. Hunt, S.P. Riege, and J.A. Prybyla, In-Situ TEM Observations of Healing Dynamics of Electromigration-Failed Interconnects, submitted to Appl. Phys. Lett.
Author information
Affiliations
Rights and permissions
About this article
Cite this article
Riege, S.P., Hunt, A.W. & Prybyla, J.A. Real-Time Tem Studies of Electromigration in Submicron Aluminum Runners. MRS Online Proceedings Library 391, 249 (1995). https://doi.org/10.1557/PROC-391-249
Published: