Abstract
Microstructural examination of a beam from Building 7 showed that temperatures higher than 940 °C were experienced in localized regions. Concurrent examination of the beam surfaces and surface layers showed evidence of extensive metal removal, and the analysis suggests that this removal occurred while the beam was exposed to the fire in the rubble pile after the building had collapsed.
Similar content being viewed by others
References
J.R. Barnett, R.R. Biederman, and R.D. Sisson, Jr: “An Initial Microstructural Analysis of A36 Steel from WTC Building, 7,”JOM-J. Min. Met. Mat. S, Dec 2001, pp. 18.
J.R. Barnett, R.R. Biederman, and R.D. Sisson, Jr.: “World Trade Center Building Performance Study: Data Collection, Preliminary Observations and Recommendations,” FEMA Report 403, Federal Emergency Management Agency, Federal Insurance and Mitigation Administration, Washington, DC, Apr 2002, Appendix C: “Limited Metallurgical Examination.”
W. Callister:Materials Science and Engineering, An Introduction, 5th ed., John Wiley & Sons, 2000.
P. Asanti and E. Kohlmeyer:Z. Anorg. Chem., 1951, {vn265}({sn94}).
R.R. Biederman, E. Sullivan, and R.D. Sisson, Jr., Worcester Polytechnic Institute, and G.F. Vander Voort, Buehler: “Microstructural Analysis of the Steels from Buildings 7, 1 and 2 from the World Trade Center,” private communication.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sisson, R.D., Biederman, R.R. Metal removal via slag attack of the steel from building 7 of the world trade center—Some observations. J Fail. Anal. and Preven. 6, 17–21 (2006). https://doi.org/10.1361/154770206X129006
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1361/154770206X129006