Abstract
Achieving the required sensitivity can be a challenge in the development of ligand binding assays for pharmacokinetic (PK) determinations of biotherapeutics. To address this need, BioScale’s Acoustic Membrane Microparticle (AMMP) technology was evaluated for the quantification of a PEGylated domain antibody (dAb) biotherapeutic. Previous uses of this technology had shown utility in biomarker and process development applications and this is the first application, to our knowledge, for PK determinations. In this evaluation, AMMP was capable of delivering a sensitivity of 0.750 ng/mL, which surpasses the sensitivity requirements for the majority of assays to support PK determinations. This evaluation demonstrates that this emerging technology has the ability to produce the required sensitivity, reproducibility, and selectivity needed to meet the industry’s standards for PK analysis.
REFERENCES
Rhyne PW, Wong OT, Zhang YJ, Weiner RS. Electrochemiluminescence in bioanalysis. Bioanalysis. 2009;1(5):919–35.
Morgan E, Varro R, Sepulveda H, Ember JA, Apgar J, Wilson J, et al. Cytometric bead array: a multiplexed assay platform with applications in various areas of biology. Clin Immunol. 2004;110(3):252–66.
Verch T, Bakhtiar R. Miniaturized immunoassays: moving beyond the microplate. Bioanalysis. 2012;4(2):177–88.
Soderstrom CI, Spriggs FP, Song W, Burrell S. Comparison of four distinct detection platforms using multiple ligand binding assay formats. J Immunol Methods. 2011;371(1–2):106–13.
Zambito F KA, Zhang Y, DeSilva B. Development of a PK immunoassay for a therapeutic monoclonal antibody using optimiser technology. Poster presented at: National Biotechnology Conference. 2013 May 22–23; San Diego CA.
Yan ZH, Madison LL, Burkhardt A, Yu J, Tayber O, Li Z, et al. Analysis of two pharmacodynamic biomarkers using acoustic micro magnetic particles on the ViBE bioanalyzer. Anal Biochem. 2011;410(1):13–8.
Collins CM, Yui S, Roberts CE, Kojic I. Thrombin detection using a piezoelectric aptamer-linked immunosorbent assay. Anal Biochem. 2013;443(1):97–103.
ACKNOWLEDGMENTS
The authors would like to acknowledge the work done by Murli Krishna and Holly Palmé in the oversight of reagent generation for this program. Steven Piccoli, Dharmesh Desai, Lora Hamuro, and Binodh DeSilva for review of this manuscript and Carol Gleason for statistical support.
Author information
Authors and Affiliations
Corresponding author
Additional information
Guest Editors: Johanna Mora and Binodh Desilva
Rights and permissions
About this article
Cite this article
Chilewski, S.D., Dickerson, W.M., Mora, J.R. et al. Evaluation of Acoustic Membrane Microparticle (AMMP) Technology for a Sensitive Ligand Binding Assay to Support Pharmacokinetic Determinations of a Biotherapeutic. AAPS J 16, 1366–1371 (2014). https://doi.org/10.1208/s12248-014-9659-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1208/s12248-014-9659-7