Dependence of detectability of microcalcification clusters on quality of mammography images

  • LM Warren
  • A Mackenzie
  • J Cooke
  • R Given-Wilson
  • M Wallis
  • D Chakraborty
  • DR Dance
  • KC Young
Poster presentation

Keywords

Image Quality Receiver Operating Characteristic Digital Mammography Mammography Image Adequate Image 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Introduction

This work compares the detection of microcalcification clusters (MC) in digital mammography images with different image quality levels.

Methods

A total of 162 normal breast images were acquired on an a-Se DR system. MC clusters extracted from magnified images of sliced mastectomies were electronically inserted into half of the images. The majority of clusters used were subtle. All images were adjusted mathematically using a validated method to simulate the appearance of images from a CR imaging system at the same dose and on both systems at half this dose. Seven experienced observers marked the location of suspicious regions, assigning a five-point score for confidence that the suspicious region was a cluster. The data were analysed using the area under the alternative free-response receiver operating characteristic (AFROC) and the area under the receiver operating characteristic (ROC) as figures of merit.

Results

There was a significant reduction in detection using CR compared with DR; the AFROC area decreased from 0.83 to 0.63 and the ROC area decreased from 0.91 to 0.79 (P < 0.0001). A significant reduction in detection was also evident at half the original dose for both DR and CR.

Conclusion

The detection of subtle clusters was reduced significantly with CR compared with DR and it is possible that CR will miss cancers manifesting as microcalcification that would be found by DR. Calcification detection was sensitive to the dose used, which should be reflected in image quality standards to ensure adequate image quality is achieved even at the cost of a higher dose.

Copyright information

© Warren et al. 2011

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Authors and Affiliations

  • LM Warren
    • 1
  • A Mackenzie
    • 1
  • J Cooke
    • 2
  • R Given-Wilson
    • 3
  • M Wallis
    • 4
  • D Chakraborty
    • 5
  • DR Dance
    • 1
    • 6
  • KC Young
    • 1
    • 6
  1. 1.National Co-ordinating Centre for the Physics of MammographyGuildfordUK
  2. 2.Jarvis Breast Screening and Diagnostic CentreGuildfordUK
  3. 3.St George's Healthcare NHS TrustLondonUK
  4. 4.Cambridge University Hospitals NHS Foundation TrustCambridgeUK
  5. 5.University of PittsburghPAUSA
  6. 6.University of SurreyGuildfordUK

Personalised recommendations