Evaluation of a partial ring design for the INSERT SPECT/MRI system

  • Kell Erlandsson
  • Debora Slavado
  • Alexandre Bousse
  • Brian Hutton
Open Access
Meeting abstract
  • 437 Downloads

Keywords

Image Quality Ring System Noisy Data Design Option Poisson Noise 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

The aim of the INSERT project is to develop a SPECT insert for a commercial MRI system, for performing simultaneous SPECT/MRI brain studies in humans. We have previously investigated various design options for the detector system, based on a complete ring of detectors. We are now considering a partial ring, due to space limitations. We have investigated the degradation in image quality with a partial ring as compared to a full ring, and the possibility of addressing the limitations by utilising MRI data during reconstruction. Noise-free data were generated by forward-projecting a cylindrical phantom with spherical inserts for a full-ring and a partial ring system, equipped with multislit- slat (MSS) and multi-pinhole (MPH) collimators. Poisson noise was added and images were reconstructed using ML-EM and MAP-EM with a smoothing prior and an anatomical prior. Contrast-recovery (CR) was calculated for the spheres in the lower part of the phantom compared to the top ones. Background CoV was also calculated. With noise-free data, CR was 77-84% for the MSS and 82-88% for the MPH partial-ring system with 400-1600 iterations. For noisy data and MAP-EM with a smoothing prior, CR was 78-80% and 81-82%, and CoV 22-28% and 26-31%, for the MSS and MPH systems, respectively. With the anatomical prior, CR was 85-89% and 87-91%, respectively. With the partial ring-systems, the transaxial resolution in the lower part of the image is reduced. The degradation is slightly larger with MSS than MPH collimators, but the MSS collimator results in a lower noise-level. Some resolution can be recovered with more iterations, but the improvement is limited when regularisation is included. The anatomical prior offers both qualitative and quantitative improvement in image quality.

Copyright information

© Erlandsson et al; licensee Springer. 2015

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Authors and Affiliations

  • Kell Erlandsson
    • 1
  • Debora Slavado
    • 1
  • Alexandre Bousse
    • 1
  • Brian Hutton
    • 1
    • 2
  1. 1.Institute of Nuclear MedicineUniversity College LondonUK
  2. 2.The Centre for Medical Radiation Physics at the University of WollongongWollongongAustralia

Personalised recommendations