Background
Feature-tracking cardiovascular magnetic resonance (FT-CMR) provides quantification of myocardial strain by analyzing cine MR images. A previous study has reported that CS measured by FT-CMR showed reasonable agreement with tagged MR in healthy volunteers. However, the usefulness of FT-CMR in patients with old myocardial infarction (OMI) has not been investigated. The purpose of this study was to evaluate diagnostic ability of CS by FT-CMR in patients with OMI.
Methods
Between March 2011 and August 2012, a total of 20 consecutive patients with OMI were enrolled in this study. All cases were performed CMR examination using a 3-Tesla MR scanner (Philips Achieva). CS by FT-CMR was analyzed using Ziostation2 (Ziosoft Inc., Tokyo, Japan). The peak subendocardial CS was quantified for 16 segments of 3 short-axis slices (basal, mid, and apical). With interobserver consensus, myocardial segments were categorized as remote normal segments (n = 173), adjacent segments (n = 70), and infarcted segments (n = 77) from the results of late gadolinium enhancement (LGE) with CMR. An infarcted segment was defined as an area with the presence of LGE. An adjacent segment was defined as an area adjacent to infarcted segment.
Results
The peak subendocardial CS was significantly lower in infarcted segments than in remote normal segments. (-6.3 ± 3.9 vs -11.8 ± 3.3; p < 0.001). Moreover, the peak subendocardial CS was significantly lower in adjacent segments than in remote normal segments. (-9.5 ± 3.7 vs -11.8 ± 3.3; p < 0.05). A cutoff value of -7.9% for peak subendocardial CS allowed differentiation between normal and infarcted segments with a sensitivity of 68%, specificity of 75%, accuracy of 73%, positive predictive value of 55%, negative predictive value of 84%, and an area under the curve (AUC) of 0.75.
Conclusions
FT-CMR can quantify myocardial strain without increasing examination time. Moreover, FT-CMR is useful for detecting infarcted segments.
Author information
Authors and Affiliations
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Ogawa, R., Kido, T., Nakamura, M. et al. Quantitative circumferential strain analysis using 3-Tesla feature-tracking cardiovascular magnetic resonance in patients with old myocardial infarction. J Cardiovasc Magn Reson 18 (Suppl 1), P84 (2016). https://doi.org/10.1186/1532-429X-18-S1-P84
Published:
DOI: https://doi.org/10.1186/1532-429X-18-S1-P84