Negative predictive value of normal adenosine-stress cardiac magnetic resonance imaging in the assessment of coronary artery disease

  • Guenter Pilz
  • Tobias Heer
  • Susanne Eierle
  • Markus Klos
  • Eman Ali
  • Roland Scheck
  • Michael Wild
  • Peter Bernhardt
  • Berthold Hoefling
Open Access
Oral presentation
  • 883 Downloads

Keywords

Coronary Artery Disease Coronary Angiography Cardiac Magnetic Resonance Cardiac Magnetic Resonance Imaging Coronary Artery Disease Patient 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Purpose

To prospectively determine the negative predictive value of normal adenosine stress cardiac magnetic resonance (CMR) in routine patients referred for evaluation of coronary artery disease (CAD), predominantly with intermediate to high pre-test risk.

Methods

Consecutive patients referred for coronary angiography were examined in a 1.5 T whole-body scanner prior to catheterization. Patients with normal CMR were included for the present analysis. Significant CAD was regarded as luminal narrowing of ≥ 70% in coronary angiography. For false-negative CMR results, exploratory semi-quantitative perfusion analysis was performed.

Results

In the 158 study patients, negative predictive value of normal adenosine-stress CMR for significant CAD was 96.2% (in the subgroup without previously known CAD: 98.3%, in patients with previous PCI: 90.7%). True negative and false negative patients were comparable regarding clinical presentation, risk factors and CMR findings. Semi-quantitative perfusion analysis gave significantly prolonged values for the arrival time index and peak time index in the false negative group.

Conclusion

The CMR exam's very high negative predictive value for CAD supports CMR-based decision making in CAD work-up to reduce the rate of superfluous diagnostic coronary angiographies. Semi-quantitative perfusion analysis may be promising to identify the small group of CAD patients not detectable by qualitative CMR assessment.

Copyright information

© Pilz et al; licensee BioMed Central Ltd. 2010

This article is published under license to BioMed Central Ltd.

Authors and Affiliations

  • Guenter Pilz
    • 1
  • Tobias Heer
    • 1
  • Susanne Eierle
    • 1
  • Markus Klos
    • 1
  • Eman Ali
    • 1
  • Roland Scheck
    • 1
  • Michael Wild
    • 1
  • Peter Bernhardt
    • 1
  • Berthold Hoefling
    • 1
  1. 1.Clinic Agatharied, University of MunichHaushamGermany

Personalised recommendations