Background

Citrus Bacterial Canker is an economic important disease in several countries, and causes great losses in fruit production and its subsidiaries [1]. There are three types of Citrus Bacterial Canker identified that have different genotypes and posses variations in host range among citrus plants. The type A CBC originating from Asia, is caused by Xanthomonas citri subsp. citri, this is the most destructive and widespread variant of the disease with a host range that includes all citrus cultivars [2]. The CBC types B and C are caused by Xanthomonas fuscans subsp. aurantifolii strains B and C, respectively. Those bacteria are limited in host range and are geographically restricted to South America. Type B CBC is present only in Argentina, Uruguay and Paraguay and is found primarily on lemon and orange [2]. Type C CBC is limited to the Sao Paulo state in Brazil and infects key or mexican lime [2]. The symptoms induced by the tree forms of canker organisms are similar and consist of cankers surrounded by chlorotic haloes and surface necrotic lesions on fruits or leaves and water-soaked lesions on leaves. Besides its leaf symptoms, this disease can cause early fruit abscission and general tree decline and the infected fruit lose market price. Moreover, quarantine restrictions are applied to prevent the spread of the pathogen to new areas, which limit drastically the trade of fresh citrus fruit with the consequent economic damage [3]. Those quarantine programs consist of rapid and reliable detection of the bacteria in all the sampled material, which include seedlings, fruits and leaves. Currently, the main procedure to detect infection is visual inspection based on disease symptoms on trees. Samples that are suspected to be positive are sent to diagnostic laboratories for further isolation on culture media. These cultures are used for reinoculation on citrus and for detection by serological methods [4]. Methodologies based on the culture of the bacterium are laborious and time consuming. In another approach, polymerase chain reaction is used for the detection of Xcc using different genomic portions as amplification targets [57]. These methods are more sensitive, specific and faster than the methods based on bacterial culture, however require modern and expensive laboratory facilities and can be difficult to perform, depending on the location. In addition, they require the use of gel electrophoresis to detect amplified products, which is long and tedious. Real-time PCR assays developed for the rapid detection of Xcc [4, 8] have the drawback of requiring an expensive thermal cycler with a fluorescence detector.

Loop-mediated isothermal amplification (LAMP) is a recent DNA amplification technique that amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions [9]. LAMP is based on the principle of autocycling strand displacement DNA synthesis performed by the Bst DNA polymerase, for the detection of a specific DNA sequence [9]. The technique uses four to six primers that recognize six to eight regions of the target DNA and provides very high specificity [9, 10]. The technique can be carried out under isothermal conditions ranging between 60 and 65°C and produces large amounts of DNA [9]. The reaction shows high tolerance to biological contaminants [11], which can help to avoid false negative results due to the inactivation of the enzyme, a common problem in PCR. Although LAMP amplification products can also be detected by gel electrophoresis, this long procedure reduces the suitability for field applications. For this reason we used SYBRGreen I, an intercalating DNA dye, and a generic lateral flow dipstick (LFD) device to detect the positive amplification by simple visual inspection, as described previously [1220], with potential field application. We optimized the assay for the amplification of a portion of the pthA gene, a well known pathogenicity determinant of CBC-causing Xanthomonas [2125]. Various LAMP assays for the detection of animal and human pathogens have been developed [20, 2633], but this technique remains uncommon for bacterial plant pathogens. Here we describe a sensitive, specific, fast, and simple LAMP assay for the detection of Citrus Bacterial Canker.

Results

Reaction conditions were optimized to establish fast and efficient parameters for amplification. Different temperatures, times and the use of loop primers, which have the capacity to accelerate the reaction, were tested [10]. The optimal amplification of the pthA gene fragment was obtained at 65°C for 30 min using loop primers, as shown by agarose gel electrophoresis (Fig. 1). Amplified products exhibited a typical ladder-like pattern. No products were observed in negative control without DNA (Fig. 1). Specificity of the amplification product was confirmed by sequencing of some bands (data not shown). The samples giving positive reaction show a green color with the addition of SYBRGreen I, while the negative control remained orange (Fig. 2). The lateral flow dipstick shows two clear lines for the positive reaction (the lower line is the sample assay band and the upper one is the control line) while the negative reaction shows only the control line (Fig. 2). CBC-LAMP assays carried out using purified DNA from other common citrus and plant pathogens gave no amplification as evidenced by gel electrophoresis, SYBRGreen stain or LFD (Table 1).

Table 1 Specificity of CBC-LAMP assay
Figure 1
figure 1

CBC-LAMP reaction optimization. Temperature, time and primer combinations applied to CBC-LAMP to determine the optimal reaction conditions. An aliquot of 15 μl of CBC-LAMP reaction aliquot was applied to 1.5% agarose gel electrophoresis and stained with ethidium bromide. C-: negative control without DNA. M: 100-bp DNA ladder.

Figure 2
figure 2

Direct analysis of CBC-LAMP products. Direct visual evaluation methods were used as follows. A-CBC-LAMP positive and negative reaction tubes were stained with SYBRGreen I and inspected under daylight. B-CBC-LAMP positive and negative reactions were subjected to lateral flow dipstick visual detection.

The CBC-LAMP detection limit was determined using Xanthomonas citri subsp. citri strain 306. The detection limit for Xcc pure DNA was 10 fg (Table 2), 5 CFU of Xcc cultured cells and 18 CFU from infected leave tissues according to the detection method used (Table 3). Positive amplification was obtained for every CBC-causing Xanthomonas strains from different regions in Argentina and around the world, including CBC types A, B and C strains. Xanthomonas axonopodis pv. citrumelo, the causative agent of Citrus Bacterial Spot, a non canker producing citrus associated bacteria, did not produced any amplification (Table 4).

Table 2 CBC-LAMP assay sensitivity from pure DNA
Table 3 CBC-LAMP assay sensitivity from cultured cells and infected tissue
Table 4 Strains of Citrus pathogenic Xanthomonas used to evaluate the CBC-LAMP assay

The potential use of this technique in location was evaluated. Infected lemon and orange fruits and leaves were collected in field. All the field samples with canker symptoms gave positive reaction using all amplicon detection methods presented in this work (Additional file 1 fig. S1).

Discussion

Citrus Bacterial Canker is a serious, aggressive disease that attacks most species of citrus worldwide. Rapid and correct diagnosis of the pathogens is crucial to minimize and control damage to the citrus industry. During the last decade several nucleic acid amplification-based methods have been developed for the detection of CBC causing-Xanthomonas [48]. These methods are fast, specific and sensitive, but are not applicable for field trials, since they can require equipment and facilities that are not easily portable. The methodology presented in this work demonstrated that CBC can be detected quickly, sensitively and specifically by using LAMP technology in an equipment-free procedure. The use of gene pthA was proven to be very selective and efficient for the diagnosis of CBC as it has been described previously [4, 6, 8]. Our studies suggest that the sensitivity could be greater than in those achieved previously by conventional PCR [5, 7] and comparable to those reported by using real-time PCR [4], although a comparative study must be performed to confirm it. On the other hand, the high sensitivity observed in this assay could require special attention in order to avoid final product contamination, a common setback in DNA-based diagnostics.

Specificity studies found no cross reaction with citrus and other plant pathogens, due to the fact that LAMP recognizes several sites in the template, improving specificity over conventional methods such as PCR [9]. Furthermore, a negative result was obtained with Xanthomonas citri pv. citrumelo, a closely related, non canker inducing Xanthomonas, ethiological agent of Citrus Bacterial Spot. This is concurrent with the fact that no pthA homolog has been found in this bacterium [6].

A BLAST search using as a query the target sequence of CBC-LAMP shows high identity with different CBC-causing Xanthomonas strains. Because pthA belongs to a family of Xanthomonas avirulence-pathogenicity genes, some grade of identity is found with other Xanthomonas spp., however as this xanthomonads do not attack citrus, this should not be a problem in diagnosing and identifying CBC, as discussed by Cubero and Graham in a previous study [6]. Positive reaction was obtained in all Xanthomonas citri subsp, citri type A strains tested, comprising reference strains and field isolates from Argentina and other countries. Interestingly the strain A*, a variant of the A strains from southwest Asia [4] is also recognized by the assay. Furthermore, CBC-LAMP was effective in the detection of type B and C strains; these results and the positive results obtained with field samples from lemon and orange confirm the robustness of the method here described for diagnosis of Citrus Bacterial Canker whatever the infecting variant is.

The DNA extraction method using Chelex allowed a fast and efficient DNA extraction from citrus plants infected with Xcc as described previously [4]. This method of sample preparation can be useful to shorten the time required in sample processing and in reducing the need for equipment. Amplicon detection by visual methods proved to be as sensitive as the gel in the case of lateral flow dipstick, but much faster and convenient. In the case of detection by adding SYBRGreen, when working with low concentrations of DNA the difference between positive and negative samples were not clear, this evidence a loss of sensitivity using the SYBRGreen detection method. Indeed we found the detection of the amplicon more robust using the lateral flow dipstick methodology as compared to the use of SYBRGreen.

The selected optimal conditions for amplification according to the experiments were 65°C for 30 minutes and with the addition of loop primers, which accelerated the reaction by hybridization to the stem loops as described previously [10]. The combination of an isothermal amplification reaction followed by a visual detection method allows the detection of this pathogen with a speed not reported so far. The time it takes to perform the test using the lateral flow dipstick is approximately 45 min including the detection of the amplification product, without DNA preparation. This speed of detection coupled with the ability to be conducted in the field can be very important in plant protection programs for citrus producers and importer countries.

Conclusions

Considering the data from the loop-mediated isothermal amplification assay combined with the lateral flow dipstick device, we conclude that the technique is specific, reliable, sensitive, fast and represents a powerful diagnostic tool for CBC. The CBC-LAMP assay requires only a simple water bath, which makes this technique suitable as a field diagnosis tool in locations where more complex laboratory equipment is not available.

Methods

Bacterial strains

Xanthomonas citri subsp. citri strain 306 [34] was the reference strain used in this study; in addition, field isolates of Xcc from several geographical origins and different pathotypes were tested. The strains used in this work belong to the strain collection of the Dr. Canteros' laboratory at Instituto Nacional de Tecnología Agropecuaria (INTA), Bella Vista, Corrientes, Argentina. All the strains were propagated on their specific medium at 28°C.

Infected Plant Tissue

For sensitivity tests, we used C. limón cv. Eureka leaves artificially inoculated with Xcc strain 306 as described previously [35]. Lemon and orange field samples were collected from citrus orchards in Tucumán province in Argentina from plants positives for CBC.

DNA extraction

For sensitivity with pure DNA and specificity assays, DNA was extracted using the Wizard® Genomic DNA purification Kit, Promega, Madison, WI, USA, according the manufacturer instructions. DNA obtained from cultured bacteria and infected tissue were purified using Chelex® 100 resin, Biorad, Hercules, CA, USA, as described previously [4].

LAMP reaction

Oligonucleotide LAMP primers were designed according to the published sequence of PthA4 gene from Xcc [GenBank: XACb0065] using the program Primer Explorer version 4 (Net Laboratory, Tokyo, Japan) targeting the 5'-end region of the gene (Fig. 3) which generated the primers XCC-F3, XCC-B3, XCC-FIP and XCC-BIP (Table 5). In addition a set of two Loop primers, XCC-LF and XCC-LB was generated for reaction acceleration (Table 5). LAMP assay was performed using a thermal dry block with a 0.5-mL PCR tube holder. Several reaction conditions were assayed, including different temperature, time (Fig. 1), and primer concentrations (data not shown). The final LAMP conditions comprised 40 pmol each of primers XCC-FIP and XCC-BIP, 5 pmol each of outer primers XCC-F3 and XCC-B3, 20 pmol each of loop primers XCC-LF and XCC-LB, 8 U of Bst DNA polymerase, 4.5 mM MgSO4, 1.4 mM of dNTP mix, 20 mM Tris-HCl (pH 8.8), 10 mM KCl, 10 mM (NH4)2SO4, 0.1% Triton X-100 and 1.6 M betaine, in a final volume of 25 μL containing the template. This mixture was incubated at 65°C for 30 minutes.

Table 5 Sequences of primers used for CBC-LAMP assay
Figure 3
figure 3

Localization of target sequences used for primer construction. Target sequences used for LAMP primer design are underlined and shadowed. The figure shows a portion of pthA gene from Xcc 449 nucleotides downstream from the start codon.

Analysis of LAMP products

The amplified products were subjected to electrophoresis at 100V for 50 minutes on a 1.5% agarose gel, followed by ethidium bromide staining. To confirm the specificity of the product some bands were cut and sequenced (data not shown). The sequences obtained were used as queries to perform BLAST searches [36] in order to confirm identity.

Direct analysis of LAMP products

For direct analysis of LAMP products, generic LFD strips (Type I BEST™ cassette, Biohelix Co, Beverly, MA, USA) were used. These strips are capable to detect an amplicon that is dual labelled with biotin and fluorescein. For this purpose we used 5'-biotin-labelled XCC-FIP primers and 5'-fluorescein-labelled XCC-BIP primers in the amplification reactions. The labelled oligonucleotides were purchased from Integrated DNA Technologies™ requesting HPLC purification. After amplification reaction, the reaction tube is inserted in the detection chamber; the dual tagged amplicon is automatically mixed with the detection buffer, and directed by capillary flow to the strip. The amplicon is detected in the test zone (T) of the cassette whereas the control zone (C) serves as a control for the flow function. The complete detection process takes about 10 minutes. More information is available in the manufacturer web site http://www.biohelix.com/products/Type_I_%26;_Type_II_Cassettes.asp.

The inspection for amplification was also performed through observation of colour change after addition of 1 μL of a 1:1000 dilution of SYBRGreen dye to the reaction tube. In the case of positive amplification the original orange color of the dye turns to green which can be examined in daylight.

Sensitivity of LAMP

In the sensitivity assay from pure DNA, 100 ng of Xcc DNA was 10-fold diluted and used as template for LAMP amplifications. For sensitivity assay from cultured cells, 10-fold dilutions of Xcc liquid culture were prepared, then a 4- μL aliquot from the dilutions were used for plating and colonies enumeration and, after DNA purification processing, 4-μL aliquots of dilutions were used as DNA template. In the assay for sensitivity from infected tissue, artificially-infected citrus leaves were used as starting material for the same procedure mentioned above.