Advertisement

BMC Ophthalmology

, 19:4 | Cite as

Pterygium surgery combined with the removal of a missed occult iris foreign body detected incidentally during pterygium examination: a case report

  • Zhitao Su
  • Houfa Yin
  • Panpan Ye
  • Xiaodan Huang
  • Li Zhang
  • Jianyun Fu
  • Xin XieEmail author
Open Access
Case report
  • 234 Downloads
Part of the following topical collections:
  1. Oculoplastics and trauma

Abstract

Background

An occult foreign body may be retained in patient with small self-sealing wound and no decreased visual acuity without complete examination. Here we report a case of a retained occult ferrous iris foreign body detected incidentally during pterygium examination.

Case presentation

A 69-year-old man presented to our ophthalmology department because of foreign body sensation and persistent redness in both eyes for 2 years. In the left eye, a pterygium, paracentral corneal opacity and a vertically oval pupil were observed. Ultrasound biomicroscopy and gonioscopy revealed a retained metallic-like foreign body partially embedded in the inferior peripheral iris. Pterygium surgery and the removal of the retained iris foreign body were performed simultaneously. No recurrent pterygium or residual foreign body was found during follow-up.

Conclusions

A thorough history should be obtained and complete physical examination should be performed in patients with ocular self-sealing wounds to prevent missed intraocular foreign bodies, which may result in potential sight-threatening ocular complications.

Keywords

Occult iris foreign body Combined surgery Pterygium Case report 

Abbreviations

IOFB

Intraocular foreign body

OGI

Open-globe injury

UBM

Ultrasound biomicroscopy

Background

Penetrating eye injury is a common condition presenting in emergency services. The frequency of intraocular foreign body (IOFB) following penetrating eye injury is approximately 40% [1, 2, 3]. In most cases, IOFBs that could cause severe visual impairment are identified. However, tiny and occult foreign bodies may be missed and retained in patients with small self-sealing wounds and no decreased visual acuity without complete examination [4, 5, 6]. The natural progression of a retained IOFB varies depending on its size and location, the toxicity of the material, and risk of infection [7]. A ferrous IOFB can cause deposition of iron molecules in the ocular tissues and result in siderosis bulbi [8, 9]. Serious ocular complications caused by retained IOFBs have been reported [10, 11, 12, 13]. In view of sight-threatening complications and the development of better surgical technique, early removal of the retained IOFBs should be performed. Asymptomatic IOFBs have been published [4, 6, 14]. However, to the best of our knowledge, there are no reports of retained iris foreign body without ocular complications. Here we present a case of an occult asymptomatic retained ferrous iris foreign body, which was detected incidentally during pterygium examination.

Case presentation

All procedures conformed to the Declaration of Helsinki, and written informed consent was obtained from the participant. A 69-year-old man was referred to our ophthalmology department because of foreign body sensation and persistent redness in both eyes for 2 years. The patient suffered a penetrating trauma to the left eye while hammering metal without safety glasses and was treated with topical antibiotics 3 months before. On presentation, the best corrected visual acuity was 20/40 in both eyes, and the intraocular pressure was 14 mmHg in the right eye and 12 mmHg in the left eye. In the left eye, pinkish, triangular tissue growth on the nasal cornea and paracentral corneal opacity at 1 o’clock position were observed. There was no inflammation in the anterior chamber. A vertically oval pupil and a moderate cortical cataract were present (Fig. 1a). Fundus examination revealed no obvious abnormality. Gonioscopy and ultrasound biomicroscopy (UBM) revealed a retained metallic-like foreign body partially embedded in the inferior peripheral iris at 6 o’clock position, which resulted in vertically oval pupil (Fig. 1b). Other foreign bodies were ruled out by B-scan ultrasonography. Except for the pterygium and moderate cortical cataract, the ocular examination was unremarkable in the right eye. Pterygium surgery and removal of the retained iris foreign body were performed simultaneously. After pterygium excision and corneal limbal autograft, a 3.0-mm superonasal clear corneal incision was made using a keratome. The ophthalmic viscoelastic device (Healon) was injected in the anterior chamber through the clear corneal incision to maintain the chamber depth, protect the endothelium and lens integrity, and dislodge the foreign body. The foreign body was captured and removed by a capculorhexis forceps through the clear corneal incision, followed by anterior chamber irrigation to remove the viscoelastic, and hydration of the clear corneal incision. After the surgery, the foreign body, 1.5 mm in width and 2.5 mm in length, was identified as a metallic foreign body by a magnet. Postoperatively, the patient received 0.5% levofloxacin eye drops and 1% prednisolone acetate eye drops 4 times a day for 1 week, and 1% pranoprofen eye drops 4 times a day for 4 weeks. The patient was followed up 1 day, 1 week, 1 month, 6 months, and 12 months after the surgery.
Fig. 1

a Anterior segment photograph showing pinkish, triangular tissue growth on the nasal cornea, paracentral corneal opacity at 1 o’clock position, and a vertically oval pupil. b Gonioscopy and ultrasound biomicroscopy showing a metallic-like foreign body partially embedded in the inferior peripheral iris at 6 o’clock position

Six months postoperatively, the best corrected visual acuity was 20/40 in the left eye, no pinkish tissue growth on the cornea was found, a nasal corneal nebula and a round pupil were observed (Fig. 2a). The moderate cortical cataract and normal fundus were the same as before surgery. No residual foreign body was identified by gonioscopy and UBM (Fig. 2b).
Fig. 2

a Anterior segment photograph showing a nasal corneal nebula and a round pupil 6 months after the surgery, and removal of the retained iris foreign body during the surgery. b Gonioscopy and ultrasound biomicroscopy showing no residual foreign body

Discussion and conclusions

Open-globe injury (OGI) can often result in serious visual loss and imposes a significant economic burden on the patient and society. IOFBs account for 18 to 41% of all OGIs [2, 3, 10]. Missed IOFBs in OGI were rare because of the relatively large size of foreign bodies and serious visual loss. However, tiny occult foreign bodies may be missed and retained in patients with small self-sealing wounds and no decreased visual acuity without complete examination [4, 5, 6, 14].

Retained iron-containing IOFBs can cause deposition of iron molecules in the ocular tissues, and siderosis bulbi will ensue if the IOFBs are not removed. The clinical findings include iris heterochromia, pupillary mydriasis, cataract formation, secondary glaucoma, and retinal pigmentary degeneration [1, 3, 8, 9]. The length of time that elapsed between the foreign body injury and presentation with siderosis ranged from 3 weeks to 8 years due to the natural course of retained IOFBs [3, 12]. Thus, when detected, an IOFB should be removed promptly to prevent these complications.

Here we report a case of an occult retained ferrous iris foreign body detected occasionally during pterygium examination. The patient suffered a penetrating trauma to the left eye while hammering metal without safety glasses 3 months before. Because of the small self-sealing corneal wound and no decreased visual acuity, he was treated only with topical antibiotics, and the IOFB was missed. Close follow-up should be required in cases of retained ferrous IOFBs without complications [3, 11, 15]. Consideration of impossible close follow-up in this patient and exposure of the ferrous foreign body in the anterior chamber, to prevent potential ocular siderosis and to reduce surgery cost, taking advance of modern surgical technique, pterygium surgery and removal of the retained iris foreign body were performed simultaneously in this case. The foreign body was identified as a metallic foreign body by a magnet after the surgery. Fortunately, the patient in the present case did not exhibit signs of ocular siderosis during follow-up. It may be associated with short duration and less amount of the harmful component.

In some cases, IOFBs (e.g., in the anterior chamber angle, embedded in the iris or lens, or on the pars plicata) cannot be visualized clinically, but can be detected by careful UBM examination [16, 17, 18]. Other indications of a possible IOFB include small self-sealing wounds, iris transillumination defect, iris heterochromia, irregular pupil, and focal lens opacities. Computed tomography scan and magnetic resonance imaging are ideal in diagnosing metallic and nonmetallic foreign bodies respectively [15, 19, 20]. However, not all IOFBs can be found even with full examination. A tiny intralenticular foreign body was found during cataract surgery in a patient with negative imaging findings [5]. Therefore, a patient accompanied by penetrating ocular injury should be suspected to have IOFB and should be followed-up closely. When IOFB was detected, it is better to remove the foreign body before irreversible siderosis bulbi occurs.

To the best of our knowledge, this is the first case of an occult missed iris foreign body that was detected incidentally during pterygium examination, followed by pterygium surgery and removal of the retained iris foreign body simultaneously. This case emphasizes the importance of a thorough history and physical examination in patients with ocular self-sealing wounds to prevent missed IOFBs, which may result in potential sight-threatening ocular complications.

Notes

Acknowledgements

None.

Funding

This study was supported by Natural Science Foundation of Zhejiang Province LY15H120001 and National Natural Science Foundation of China (Grant No. 81370019 and 81870624).

Authors’ contributions

ZTS collected the data and drafted the manuscript. HFY, PPY and XDH collected the data. JYF and LZ participated in diagnosis and treatment of the patient. XX guided the study and revised the manuscript. All authors have read and approved the final manuscript.

Ethics approval and consent to participate

This report has been performed in accordance with the Declaration of Helsinki. As this is a single case report that does not include data that can identify the patient, no ethical approval was required by Ethics Committee of the Second Affiliated Hospital, Zhejiang University School of Medicine.

Consent for publication

Written informed consents were obtained from the patient for publication of this case report and any accompanying images.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  1. 1.
    Yeh S, Colyer MH, Weichel ED. Current trends in the management of intraocular foreign bodies. Curr Opin Ophthalmol. 2008;19(3):225–33.CrossRefGoogle Scholar
  2. 2.
    Yigit O, Yuruktumen A, Arslan S. Foreign body traumas of the eye managed in an emergency department of a single-institution. Ulus Travma Acil Cerrahi Derg. 2012;18(1):75–9.CrossRefGoogle Scholar
  3. 3.
    Loporchio D, Mukkamala L, Gorukanti K, Zarbin M, Langer P, Bhagat N. Intraocular foreign bodies: a review. Surv Ophthalmol. 2016;61(5):582–96.CrossRefGoogle Scholar
  4. 4.
    Chang YS, Jeong YC, Ko BY. A case of an asymptomatic intralenticular foreign body. Korean J Ophthalmol. 2008;22(4):272–5.CrossRefGoogle Scholar
  5. 5.
    Koutsonas A, Plange N, Roessler GF, Walter P, Mazinani BA. A case of siderosis bulbi without a radiologically detectable foreign body. Can J Ophthalmol. 2013;48(1):e9–e11.CrossRefGoogle Scholar
  6. 6.
    Foss AJ, Forbes JE, Morgan J. An intralenticular foreign body and a clear lens. Br J Ophthalmol. 1993;77(12):828.CrossRefGoogle Scholar
  7. 7.
    Dhawahir-Scala FE, Kamal A. Intralenticular foreign body: a D-day reminder. Clin Exp Ophthalmol. 2005;33(6):659–60.CrossRefGoogle Scholar
  8. 8.
    Appel I, Barishak YR. Histopatholocial changes in siderosis bulbi. OPHTHALMOLOGICA. 1978;176(4):205–10.CrossRefGoogle Scholar
  9. 9.
    Tawara A. Transformation and cytotoxicity of iron in siderosis bulbi. Invest Ophthalmol Vis Sci. 1986;27(2):226–36.PubMedGoogle Scholar
  10. 10.
    Zhang Y, Zhang M, Jiang C, Qiu HY. Intraocular foreign bodies in China: clinical characteristics, prognostic factors, and visual outcomes in 1,421 eyes. Am J Ophthalmol. 2011;152(1):66–73.CrossRefGoogle Scholar
  11. 11.
    Wu TT, Kung YH, Sheu SJ, Yang CA. Lens siderosis resulting from a tiny missed intralenticular foreign body. J CHIN MED ASSOC. 2009;72(1):42–4.CrossRefGoogle Scholar
  12. 12.
    Zhu L, Shen P, Lu H, Du C, Shen J, Gu Y. Ocular trauma score in Siderosis bulbi with retained intraocular foreign body. Medicine (Baltimore). 2015;94(39):e1533.CrossRefGoogle Scholar
  13. 13.
    O'Duffy D, Salmon JF. Siderosis bulbi resulting from an intralenticular foreign body. Am J Ophthalmol. 1999;127(2):218–9.CrossRefGoogle Scholar
  14. 14.
    Niazi MK, Arain MA, Khan MD, Dar AJ, Yaqub A, Adeeb L. Intralenticular foreign body with a clear lens. J Coll Physicians Surg Pak. 2010;20(3):214–5.PubMedGoogle Scholar
  15. 15.
    Gor DM, Kirsch CF, Leen J, Turbin R, Von Hagen S. Radiologic differentiation of intraocular glass: evaluation of imaging techniques, glass types, size, and effect of intraocular hemorrhage. AJR Am J Roentgenol. 2001;177(5):1199–203.CrossRefGoogle Scholar
  16. 16.
    Deramo VA, Shah GK, Baumal CR, Fineman MS, Correa ZM, Benson WE, Rapuano CJ, Cohen EJ, Augsburger JJ. Ultrasound biomicroscopy as a tool for detecting and localizing occult foreign bodies after ocular trauma. OPHTHALMOLOGY. 1999;106(2):301–5.CrossRefGoogle Scholar
  17. 17.
    Berinstein DM, Gentile RC, Sidoti PA, Stegman Z, Tello C, Liebmann JM, Ritch R. Ultrasound biomicroscopy in anterior ocular trauma. Ophthalmic Surg Lasers. 1997;28(3):201–7.PubMedGoogle Scholar
  18. 18.
    Mahendradas P, Vijayan PB, Avadhani K, Garudadri S, Shetty BK. Usefulness of anterior segment optical coherence tomography in the demonstration of intralenticular foreign body in traumatic cataract. Can J Ophthalmol. 2010;45(4):413–4.CrossRefGoogle Scholar
  19. 19.
    LoBue TD, Deutsch TA, Lobick J, Turner DA. Detection and localization of nonmetallic intraocular foreign bodies by magnetic resonance imaging. Arch Ophthalmol. 1988;106(2):260–1.CrossRefGoogle Scholar
  20. 20.
    Patel SN, Langer PD, Zarbin MA, Bhagat N. Diagnostic value of clinical examination and radiographic imaging in identification of intraocular foreign bodies in open globe injury. Eur J Ophthalmol. 2012;22(2):259–68.CrossRefGoogle Scholar

Copyright information

© The Author(s). 2019

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Authors and Affiliations

  1. 1.Eye Center, Second Affiliated Hospital, School of MedicineZhejiang UniversityHangzhouChina
  2. 2.The Second People’s Hospital of QuzhouQuzhouChina

Personalised recommendations