Extending the Application Field of Vacuum Circuit Breakers to Generators for Capacities up to 400 MW

  • Electrical Part of Thermal and Nuclear Power Plants
  • Published:
Thermal Engineering Aims and scope Submit manuscript

Abstract

The progress that has been achieved in the development and manufacture of vacuum circuit breakers opens the possibility of using them for a wider range of applications at power plants, including as generator circuit breakers. Such characteristics of modern vacuum circuit breakers as increased breaking capacity and high switching life are factors that make them closer in competitiveness to SF6 circuit breakers for generators with capacities up to 400 MW. The article considers problem aspects relating to clearing of short-circuit faults in the generator voltage circuits and interruption of out-of-phase making currents and no-load currents of generator transformers. Conditions leading to a longer period of time to the moment at which the switched current crosses zero are considered. It is pointed out that, unlike the IEC/IEEE Standard 62271-37-013, GOST (State Standard) R 52565-2006 does not specify the requirements for generator circuit breakers in full. The article gives the voltage drop values across the arc for different design versions of vacuum circuit breaker contacts and shows the effect the arc in a vacuum circuit breaker has on the time delay to the moment at which the current crosses zero. The standardized parameters of transient recovery voltage across the generator circuit breaker contacts are estimated along with the contact gap electric strength recovery rates ensured by modern arc quenching chambers. The switching overvoltages arising when vacuum circuit breakers interrupt short-circuit currents and no-load currents of generator transformers are analyzed. The article considers the most probable factors causing the occurrence of switching overvoltages, including current chopping, repeated breakdowns of the circuit breaker contact gap, and virtual current chopping. It is found that, unlike repeated breakdowns and virtual current chopping, an actual current chopping does not give rise to dangerous switching overvoltages. The article also determines the vacuum circuit breaker application field boundaries in which dangerous switching overvoltages may occur that would require additional measures for limiting them.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. GOST R 52565-2006. Alternating-Current Circuit-Breakers for Voltages from 3 to 750 kV. General Specifications (Standartinform, Moscow, 2007).

  2. IEC/IEEE 62271-37-013 High-Voltage Switchgear and Controlgear — Part 37-013: Alternating-Current Generator Circuit-Breakers (Int. Electrotechnical Commission, 2015).

  3. P. A. Sheiko, “6–24 kV generator circuit breakers. The problem of choice and application,” Nov. Elektrotekh., No. 2, 70–72 (2006).

    Google Scholar 

  4. A. N. Nazarychev, “Analysis of main advantages of the use of vacuum circuit breakers,” Energoekspert, No. 4–5, 58–63 (2007).

    Google Scholar 

  5. K. Venna, N. Anger, and T. Kleinert, “Role of vacuum generator circuit breaker in improving the plant efficiency & protecting the generators up to 450 MVA,” in Proc. POWER-GEN Europe 2016, Milan, June 21–23, 2016 (PennWell, 2016).

    Google Scholar 

  6. Test Order No. 14-00626, Hochspannungs-und Schaltleistungsprüfungen, Schalter-3AH36 (Siemens AG, 2015).

  7. R. K. Smith, R. W. Long, and D. L. Burminghan, “Vacuum interrupters for generator circuit breakers they’re not just for distribution circuits breakers anymore,” in Proc. 17th CIRED Conf. on Electricity Distribution, Barcelona, May 12–15, 2003 (CIRED, 2003).

    Google Scholar 

  8. S. A. Ul’yanov, Electromagnetic Transients in Electric Systems. Textbook (Energiya, Moscow, 1970) [in Russian].

  9. D. Braun and G. Koeppl, “Transient recovery voltages during the switching under out-of-phase conditions,” in Proc. Int. Conf. on Power Systems Transients (IPST 2003), New Orleans, Sept. 28–Oct. 2, 2003.

  10. W. M. C. van den Heuvel, Doctoral Dissertation in Engineering (Technische Hogeschool Eindhoven, Eindhoven, 1966). doi 10.6100/IR76586

    Google Scholar 

  11. M. Murano, S. Yanabu, H. Ohashi, H. Ishizuka, and T. Okazaki, “Current chopping phenomena of medium voltage circuit breakers,” IEEE Trans. Power Appar. Syst. 96, 143–149 (1977).

    Article  Google Scholar 

  12. R. D. Garzon, High Voltage Circuit Breakers. Design and Applications (CRC, New York, 2002). doi 10.1109/ MEI.1998.730820

    Book  Google Scholar 

  13. G. Evdokunin and S. Titenkov, “Overvoltages in 6(10) kV grids are caused by both vacuum and SF6 circuit breakers,” Nov. Elektrotekh., No. 5, 27–29 (2002).

    Google Scholar 

  14. V. S. Larin, A. K. Lokhanin, and P. A. Sheiko, “A study of switching overvoltages caused by the work of vacuum generator circuit breakers VGG-10 and VGGm-10 at Kamskaya GES,” Elektrichestvo, No. 9, 31–40 (2011).

    Google Scholar 

  15. Degtyarev I. L. Candidate’s Dissertation in Engineering (Novosibirsk State Technical Univ., Novosibirsk, 2006).

    Google Scholar 

  16. A. Mueller, “Switching phenomena in medium voltage systems. Good engineering practice on the application of vacuum circuit-breakers and contactors,” in Proc. 2011 Eur. Conf. on Electrical and Instrumentation Applications in the Petroleum & Chemical Industry (PCIC Europe), Rome, June 7–9, 2011 (IEEE, New York, 2011).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to K. Venna.

Additional information

Original Russian Text © K. Venna, Yu.P. Gusev, E.P. Oknin, G.Ch. Cho, 2018, published in Teploenergetika.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Venna, K., Gusev, Y.P., Oknin, E.P. et al. Extending the Application Field of Vacuum Circuit Breakers to Generators for Capacities up to 400 MW. Therm. Eng. 65, 200–207 (2018). https://doi.org/10.1134/S0040601518040092

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1134/S0040601518040092

Keywords

Navigation