Abstract
Based on CT scanning pictures from a volunteer’s knee joint, a three-dimensional finite element model of the healthy human knee joint is constructed including complete femur, tibia, fibular, patellar and the main cartilage and ligaments. This model was validated using experimental and numerical results obtained from other authors. The pressure distribution of contact surfaces of knee joint are calculated and analyzed under the load action of ‘heel strike’, ‘single limb stance’ and ‘toe-off’. The results of the gait cycle are that the contact areas of medial cartilage are larger than that of lateral cartilage; the contact force and contact areas would grow larger with the load increasing; the pressure of lateral meniscus is steady, relative to the significant variation of peak pressure in medial meniscus; and the peak value of contact pressure on all components are usually found at about 45% of the gait cycle.
Similar content being viewed by others
References
Bendjaballah, M.Z., Shirazi-Adl, A. and Zukor, D.J., Biomechanics of the human knee joint in compression: reconstruction, mesh generation and finite element analysis. Knee, 1995, 2: 69–79.
Beynnon B., Yu J., Huston D., etc., A sagittal plane model of the knee and cruciate ligaments with application of a sensitivity analysis. ASME Journal of Biomechanical Engineering, 1996, 118: 227–239
Heegard, J., Leyvraz, P.F. and Curnier, A., etc., The biomechanics of the human patella during passive knee flexion. Journal of Biomechanics, 1995, 28: 1265–1279.
Périé, D. and Hobatho M.C., In vivo determination of contact areas and pressure of the femorotibial joint using nonlinear finite element analysis. Clinical Biomechanics, 1998, 13: 394–402.
Li, G., Gill, J. and Kanamori, A., etc., A validated three-dimensional computational model of a human joint. ASME Journal of Biomechanical Engineering, 1999, 121: 657–662.
Peña, E., Calvo, B. and Martinez, M.A., etc., A three-dimensional finite element analysis of the combined behaviour of ligaments and menisci in the healthy human knee joint. Journal of Biomechanics, 2006, 39: 1686–1701.
Shirazi-Adl, A. and Mesfar, W., Effect of tibial tubercle elevation on biomechanics of the entire knee joint under muscle loads. Clinical Biomechanics, 2007, 22: 344–351.
Armstrong, C., Lai, W. and Mow, V., An analysis of the unconfined compression of articular cartilage. ASME Journal of Biomechanical Engineering, 1984, 106: 165–173.
Murakam, T., The lubrication in natural synovial joints and joint prostheses. JSME International Journal, 1990, 33: 465–474.
Taylor, S.J.G., Walker, P.S. and Perry J.S., etc., The forces in the distal femur and the knee during walking and other activities measured by telemetry. Journal of Arthroplasty, 1998, 13: 428–437.
Hao, Z.X., Jin, D.W. and Zhang, J.C., etc., Finite element analysis of in vivo tibio-femora l con tact features with menisci. Journal of Tsinghua University, 2008, 48(2): 176–179.
Ashvin, T., James, C.H.G. and Shamal D.D., Contact stresses in the knee joint in deep flexion. Medical Engineering & Physics, 2005, 27: 329–335.
Godest, A.C., Beaugonin, M. and Haug, E., etc., Simulation of a knee joint replacement during a gait cycle using explicit element analysis. Journal of Biomechanics, 2002, 35(2): 267–275.
Jia, X.H., Zhang, M., Lee, W.C.C., Load transfer mechanics between trans-tibial prosthetic socket and residual limb-dynamic effects. Journal of Biomechanics, 2004, 37: 1371–1377.
Author information
Authors and Affiliations
Additional information
Project supported by the National Natural Science Foundation of China (No. 10702048).
Rights and permissions
About this article
Cite this article
Guo, Y., Zhang, X. & Chen, W. Three-dimensional Finite Element Simulation of Total Knee Joint in Gait Cycle. Acta Mech. Solida Sin. 22, 347–351 (2009). https://doi.org/10.1016/S0894-9166(09)60283-4
Received:
Revised:
Published:
Issue Date:
DOI: https://doi.org/10.1016/S0894-9166(09)60283-4