Abstract

Chip-based flow-through PCR implements the PCR as a continuous process for nucleic acid analytics. The sample is transported in a winding channel through temperature zones required for denaturation, annealing and extension. Main fields of application are the monitoring of continuous processes for rapid identification of contaminants and quality control as well as high throughput screening of cells or microorganisms. A modular arrangement with five heating zones for flow-through PCR is discussed and evaluated. The special heater arrangement allows the implementation of up to 40 cycles on the footprint of a microscope slide, which is placed on top of a 5 zones heating plate. Liquid/liquid two phase flow of PCR reaction mixture and mineral oil have been applied to create a segmented flow process scheme. In that way, the developed system may provide flow-through PCR as a unit operation for the droplet based microfluidics platform. The single use of disposable devices is commonly preferred due to the sensitivity of the PCR process to contaminations. All-glass microfluidic chips and disposable chip devices, made from polycarbonate as a replication with identically geometry, have been fabricated and tested. For the first time, microchannel geometries with nearly circular profile developed by all-glass technology have been transferred to mass fabrication by injection compression molding. Both devices have been successfully applied for the detection of the tumor suppressor gene p53. Although product yield and selectivity of the amplification process do not depend on the chip material, a well defined, reliable segmented flow regime could only be realized in the all-glass chip.

Keywords

lab-on-a-chip PCR microfluidics two-phase-flow injection molding point-of-care biomedical 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. [1]
    Sakai R K, Scharf S, Faloona F, Mullis K B, Horn G T, Erlich H A, Arnheim N. Enzymatic amplification of β-globin genomic sequences and restriction site analysis for diagnosis of sick cell anemia. Science, 1985, 230, 1350–1354.CrossRefGoogle Scholar
  2. [2]
    Mullis K B, Ferré F, Gibbs R A. The Polymerase Chain Reaction, Birkhäuser, Boston, 1994.CrossRefGoogle Scholar
  3. [3]
    Chen L, Manz A, Day P J R. Total nucleic acid analysis integrated on microfluidic devices. Lab on A Chip, 2007, 7, 1413–1423.CrossRefGoogle Scholar
  4. [4]
    Lee S J, Lee S Y. Micro total analysis system (micro-TAS) in biotechnology. Appl. Microbiol. Biotechnol., 2004, 64, 289–299.CrossRefGoogle Scholar
  5. [5]
    Vilkner T, Janasek D, Manz A. Micro total analysis systems. Recent developments. Anal. Chem., 2004, 76, 3373–3385.CrossRefGoogle Scholar
  6. [6]
    Manz A, Graber N, Widmer H M. Miniaturized total chemical analysis systems: A novel concept for chemical sensing. Sensors and Actuators B: Chemical, 1990, 1, 244–248.CrossRefGoogle Scholar
  7. [7]
    Felbel J, Reichert A, Kielpinskl M, Urban M, Henkel T, Hafner N, Dürst M, Weber J. Reverse transcription-polymerase chain reaction (RT-PCR) in flow-through micro-reactors: Thermal and fluidic concepts. Chemical Engineering Journal, 2008, 135, 298–302.CrossRefGoogle Scholar
  8. [8]
    Becker H, Klemm R, Gärtner C. Reliable continuous-flow PCR from polymerase kits and on-chip cell extracted DNA. Proceedings of the 11th International Conference on Miniaturized Systems for Chemistry and Life Sciences μTAS, Paris, France, 2007, 1273–1275.Google Scholar
  9. [9]
    Henkel T, Bermig T, Kielpinskl M, Grodrian A, Metze J, Köhler J M. Chip modules for generation and manipulation of fluid segments for micro serial flow processes. Chemical Engineering Journal, 2004, 101, 439–445.CrossRefGoogle Scholar
  10. [10]
    Kreutzer M T, Gunther A, Jensen K F. Sample dispersion for segmented flow in microchannels with rectangular cross section. Analytical Chemistry, 2008, 80, 1558–1567.CrossRefGoogle Scholar
  11. [11]
    Kreutzer M T, Kapteijn F, Moulijn J A, Heiszwolf J J. Multiphase monolith reactors: Chemical reaction engineering of segmented flow in microchannels. Chemical Engineering Science, 2005, 60, 5895–5916.CrossRefGoogle Scholar
  12. [12]
    Kutchoukov V G, Laugere F, van der Vlist W, Pakula L, Garini Y, Bossche A. Fabrication of nanofluidic devices using glass-to-glass anodic bonding. Sensors and Actuators A: Physical, 2004, 114, 521–527.CrossRefGoogle Scholar
  13. [13]
    Brugger R. Galvanic nickel plating, 2nd ed., Eugen G. Leuze Verlag, Saulgau/Württ, Germany, 1984. (in German)Google Scholar
  14. [14]
    Gale B K, Sundberg S O, Eddings M A, Hatch A, Ho T, Kim J. Low-cost MEMS technologies. In: Comprehensive Microsystems, Elsevier, Oxford, 2008, 1, 341–378.CrossRefGoogle Scholar

Copyright information

© Jilin University 2008

Authors and Affiliations

  • Anett Reichert
    • 1
  • Jana Felbel
    • 1
  • Mark Kielpinski
    • 1
  • Matthias Urban
    • 1
  • Benno Steinbrecht
    • 2
  • Thomas Henkel
    • 1
    Email author
  1. 1.Microfluidics DepartmentInstitute of Photonic TechnologyJenaGermany
  2. 2.Arvato Digital Services Manufacturing EMEAGüterslohGermany

Personalised recommendations