Study on Protective Relay Operation in a Power Distribution System with a Trigger-Type SFCL Using Twice Triggering Operations

  • Sung-Hun Lim
  • Jin-Seok Kim
Regular Paper
  • 4 Downloads

Abstract

This paper proposes a trigger type superconducting fault current limiter (SFCL), which consists of a switch, two superconducting modules, and two series connected current limiting resistances (CLRs), using twice triggering operations. The suggested trigger type SFCL has twice the triggering operations according to the amplitude of the fault current. However, these operations are thought to affect the operation of the protective relay in a power distribution system. According to the fault conditions that affect the operation of the protective relay in a power distribution system, the fault location was selected. With two representative fault locations, the fault current limiting and the bus-voltage sag suppressing characteristics in a power distribution system with the suggested SFCL were analyzed. For comparative studies, the operation of the protective relay due to the conventional trigger type SFCL using one CLR was additionally described.

Keywords

Trigger type superconducting fault current limiter (SFCL) Twice triggering operations Fault current Protective relay Fault current limiting and bus-voltage sag suppressing characteristics 

Notes

Acknowledgements

This work was supported by the National Research Foundation of Korea (NRF) Grant Funded by the Korea government (MOE) (No. 2017R1D1A1B03036530).

References

  1. 1.
    A. J. Power, An overview of transmission fault currents, in Colloquian on fault limiters-look at tomorrow. IEE London, Digest 1995/026 (1995)Google Scholar
  2. 2.
    E. Thuries, V.D. Pham, Y. Laumond, T. Verhaege, A. Fevrier, M. Collet, M. Bekhaled, Toward the superconducting fault current limiter. IEEE Trans. Power Deliv. 6(2), 801–808 (1991)CrossRefGoogle Scholar
  3. 3.
    W. Paul, M. Chen, Superconducting control for surge currents. IEEE Spectr. 35, 49–54 (1998)CrossRefGoogle Scholar
  4. 4.
    L. Ye, A. Campbell, Behavior investigations of superconducting fault current limiters in power systems. IEEE Trans. Appl. Supercond. 16(2), 662–665 (2006)CrossRefGoogle Scholar
  5. 5.
    T. Hori, A. Otani, K. Kaiho, I. Yamaguchi, M. Morita, S. Yanabu, Study of superconducting fault current limiter using vacuum interrupter driven by electromagnetic repulsion force for commutating switch. IEEE Trans. Appl. Supercond. 16(4), 1999–2003 (2006)CrossRefGoogle Scholar
  6. 6.
    T. Hori, M. Endo, T. Koyama, I. Yamaguchi, K. Kaiho, M. Furuse, S. Yanabu, Study of kV class current limiting unit with YBCO thin films. IEEE Trans. Appl. Supercond. 17(2), 1986–1989 (2007)CrossRefGoogle Scholar
  7. 7.
    S.-H. Lim, J.-C. Kim, B.-W. Lee, Improvement of recovery characteristics of a flux-lock type SFCL using a superconductor’s trigger. IEEE Trans. Appl. Supercond. 20(3), 1182–1185 (2010)CrossRefGoogle Scholar
  8. 8.
    S.-H. Lim, Analysis on current limiting characteristics of a flux-lock type SFCL with two triggering current levels. Physica C 471, 1354–1357 (2011)CrossRefGoogle Scholar
  9. 9.
    S.-H. Lim, I.-K. You, J.-C. Kim, Study on peak current limiting characteristics of a flux-lock type SFCL using its third winding. IEEE Trans. Appl. Supercond. 21(3), 1275–1279 (2011)CrossRefGoogle Scholar

Copyright information

© The Korean Institute of Electrical and Electronic Material Engineers 2018

Authors and Affiliations

  1. 1.Department of Electrical EngineeringSoongsil UniversitySeoulKorea
  2. 2.Department of Electrical EngineeringSeoil UniversitySeoulKorea

Personalised recommendations