Development of non-contact patient head alignment device (HEAD) for X-ray imaging for skull true lateral projection

  • Original Paper
  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

A Correction to this article was published on 29 March 2021

This article has been updated

Abstract

The purpose of this study was to evaluate the accuracy of the developed auxiliary head alignment device for true X-ray skull lateral projection and evaluate the accuracy of skull true lateral imaging according to the use of this device by applying a skull phantom. The developed non-contact patient head alignment device (HEAD) for radiography was intended to enable someone with minimal experience with X-ray imaging to inspect an accurate skull true lateral projection and ensure the reproducibility of the inspection. The tilting and rotation of the skull X-ray images were evaluated by comparing the positions of the mandibular condylar processes observed from both sides. A paired t test was performed for the differences in tilting and rotational changes before and after using the HEAD for skull lateral projection. In addition, the interclass correlation coefficient (ICC) was used for reliability evaluation according to the use of the HEAD at different times. The mean length of the left and right intervals of both intercondylar processes indicating rotation before and after the use of the HEAD was 7.25 ± 2.62 and 2.24 ± 1.32, respectively (p < 0.01). The upper and lower intervals of both intercondylar processes indicating tilting of the head were 8.18 ± 2.24 without the HEAD and 2.60 ± 1.92 using the device (p < 0.01). Using the developed HEAD, a skull lateral X-ray image with very accurate information for the patient’s diagnosis can be acquired

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

Change history

References

  1. M.J. Diament, J. Allergy Clin. Immunol. 90(3 Pt 2), 442 (1992)

    Article  Google Scholar 

  2. H.J. Yang, R.Y. Liu, Y.L. Liu, Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi 28(6), 457 (2010)

    Google Scholar 

  3. G.H. Chen, J. Zambelli, N. Bevins, Z. Qi, K. Li, Curr. Med. Imaging Rev. 6(2), 90 (2010)

    Article  Google Scholar 

  4. L. Qian, J. Pan, Z.D. Liu, L.J. Li, J. Tan et al., Spinal Cord 51(12), 904 (2013)

    Article  Google Scholar 

  5. M. Bozbuga, A. Ozturk, Z. Ari, K. Sahinoglu, B. Bayraktar et al., Okajimas Folia. Anat. Jpn. 75(1), 33 (1998)

    Article  Google Scholar 

  6. S.R. Sharp, S.M. Patel, R.E. Brown, C. Landes, Clin. Radiol. 73(5), 449 (2018)

    Article  Google Scholar 

  7. R.M. Katz, S. Friedman, M. Diament, S.C. Siegel, G.S. Rachelefsky et al., Allergy Proc. 16(3), 123 (1995)

    Article  Google Scholar 

  8. M. Knorgen, S. Brandt, S. Kosling, Rofo 184(12), 1153 (2012)

    Article  Google Scholar 

  9. M.F. Feres, J.S. Hermann, M. Cappellette Jr., S.S. Pignatari, Int. J. Pediatr. Otorhinolaryngol. 75(1), 1 (2011)

    Article  Google Scholar 

  10. N.A. Marathe, A.A. Dahapute, J.R. Desai, K.P. Dhole, S. Bhaladhare et al., Asian J. Neurosurg. 14(4), 1116 (2019)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Seung-Man Yu.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yu, SM. Development of non-contact patient head alignment device (HEAD) for X-ray imaging for skull true lateral projection. J. Korean Phys. Soc. 78, 550–556 (2021). https://doi.org/10.1007/s40042-021-00108-z

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40042-021-00108-z

Keywords

Navigation