Abstract

Bile acid authentic standards were used as model compounds to quantitatively evaluate complex in-source phenomenon on a UPLC-ESI-TOF-MS operated in the negative mode. Three different diameter columns and a ceramic-based microfluidic separation device were utilized, allowing for detailed descriptions of bile acid behavior across a wide range of flow regimes and instantaneous concentrations. A custom processing algorithm based on correlation analysis was developed to group together all ion signals arising from a single compound; these grouped signals produce verified compound spectra for each bile acid at each on-column mass loading. Significant adduction was observed for all bile acids investigated under all flow regimes and across a wide range of bile acid concentrations. The distribution of bile acid containing clusters was found to depend on the specific bile acid species, solvent flow rate, and bile acid concentration. Relative abundancies of each cluster changed non-linearly with concentration. It was found that summing all MS level (low collisional energy) ions and ion-neutral adducts arising from a single compound improves linearity across the concentration range (0.125–5 ng on column) and increases the sensitivity of MS level quantification. The behavior of each cluster roughly follows simple equilibrium processes consistent with our understanding of electrospray ionization mechanisms and ion transport processes occurring in atmospheric pressure interfaces.

Graphical Abstract

Keywords

Electrospray Ion-neutral clustering Adduction Liquid chromatography Time-of-flight Mass spectrometry Bile acids Quantification 

Notes

Acknowledgments

The authors acknowledge Waters Corporation for postdoctoral research funding and support for this project. The authors also acknowledge Angela Doneanu of Waters Corporation for technical support.

Supplementary material

13361_2017_1878_MOESM1_ESM.docx (3 mb)
ESM 1 (DOCX 3046 kb)

References

  1. 1.
    Broeckling, C.D., Ganna, A., Layer, M., Brown, K., Sutton, B., Ingelsson, E., Peers, G., Prenni, J.E.: Enabling efficient and confident annotation of LC-MS metabolomics data through MS1 spectrum and time prediction. Anal. Chem. 88, 9226–9234 (2016)CrossRefGoogle Scholar
  2. 2.
    Alechaga, É., Moyano, E., Galceran, M.T.: Ion-molecule adduct formation in tandem mass spectrometry. Anal. Bioanal. Chem. 408, 1269–1277 (2016)CrossRefGoogle Scholar
  3. 3.
    Keller, B.O., Sui, J., Young, A.B., Whittal, R.M.: Interferences and contaminants encountered in modern mass spectrometry. Anal. Chim. Acta 627, 71–81 (2008)Google Scholar
  4. 4.
    Kruve, A., Kaupmees, K.: Adduct formation in ESI/MS by mobile phase additives. J. Am. Soc. Mass Spectrom. 28, 887–894 (2017)Google Scholar
  5. 5.
    Li, X.-F., Ma, M., Scherban, K., Tam, Y.K.: Liquid chromatography-electrospray mass spectrometric studies of ginkgolides and bilobalide using simultaneous monitoring of proton, ammonium and sodium adducts. Analyst 127, 641–646 (2002)Google Scholar
  6. 6.
    Metwally, H., McAllister, R.G., Konermann, L.: Exploring the mechanism of salt-induced signal suppression in protein electrospray mass spectrometry using experiments and molecular dynamics simulations. Anal. Chem. 87, 2434–2442 (2015)CrossRefGoogle Scholar
  7. 7.
    Gamero-Castaño, M., Fernández De La Mora, J.: Mechanisms of electrospray ionization of singly and multiply charged salt clusters. Anal. Chim. Acta. 406, 67–91 (2000)CrossRefGoogle Scholar
  8. 8.
    Zook, D.R., Bruins, A.P.: On cluster ions, ion transmission, and linear dynamic range limitations in electrospray (ionspray) mass spectrometry. Int. J. Mass Spectrom. Ion Processes. 162, 129–147 (1997)CrossRefGoogle Scholar
  9. 9.
    Meng, C.K., Fenn, J.B.: Formation of charged clusters during electrospray ionization of organic solute species. Org. Mass Spectrom. 26, 542–549 (1991)CrossRefGoogle Scholar
  10. 10.
    Dole, M., Mack, L.L., Hines, R.L., Mobley, R.C., Ferguson, L.D., Alice, M.B., Malcolm Dole, L.L.M., Marck, L.L., Hines, L., Mobley, R.C., Ferguson, L.D., Alice, M.B.: Molecular beams of macroions. J. Chem. Phys. 49, 2240–2249 (1968)CrossRefGoogle Scholar
  11. 11.
    Thomson, B.A.: Atmospheric pressure ionization and liquid chromatography/mass spectrometry—together at last. J. Am. Soc. Mass Spectrom. 9, 187–193 (1998)CrossRefGoogle Scholar
  12. 12.
    Thomson, B.A., Iribarne, J.V., Dziedzic, P.J.: Liquid ion evaporation/mass spectrometry/mass spectrometry for the detection of polar and labile molecules. Anal. Chem. 54, 2219–2224 (1982)CrossRefGoogle Scholar
  13. 13.
    Thomson, B.A., Iribarne, J.: V: Field induced ion evaporation from liquid surfaces at atmospheric pressure. J. Chem. Phys. 71, 4451–4463 (1979)CrossRefGoogle Scholar
  14. 14.
    Iribarne, J.V., Thomson, B.A.: On the evaporation of small ions from charged droplets. J. Chem. Phys. 64, 2287 (1976)CrossRefGoogle Scholar
  15. 15.
    Hayes, J.M., Small, G.J.: Supersonic jets, rotational cooling, and analytical chemistry. Anal. Chem. 55, 565A–574A (1983)CrossRefGoogle Scholar
  16. 16.
    Proctor, C.J., Todd, J.F.J.: Atmospheric pressure ionization mass spectrometry. Org. Mass Spectrom. 18, 509–516 (1983)CrossRefGoogle Scholar
  17. 17.
    Carroll, D.I., Dzidic, I., Horning, E.C., Stillwell, R.N.: Atmospheric pressure ionization mass spectrometry. Appl. Spectrosc. Rev. 17, 337–406 (1981)CrossRefGoogle Scholar
  18. 18.
    Whitehouse, C.M., Dreyer, R.N., Yamashita, M., Fenn, J.B.: Electrospray interface for liquid chromatographs and mass spectrometers. Anal. Chem. 57, 675–679 (1985)CrossRefGoogle Scholar
  19. 19.
    Klee, S., Derpmann, V., Wißdorf, W., Klopotowski, S., Kersten, H., Brockmann, K.J., Benter, T., Albrecht, S., Bruins, A.P., Dousty, F., Kauppila, T.J., Kostiainen, R., O ’Brien, R., Robb, D.B., Syage, J.A.: Are clusters important in understanding the mechanisms in atmospheric pressure ionization? Part 1: Reagent ion generation and chemical control of ion populations. J. Am. Soc. Mass Spectrom. 25, 1310–1321 (2014)CrossRefGoogle Scholar
  20. 20.
    Albrecht, S., Klopotowski, S., Derpmann, V., Klee, S., Brockmann, K.J., Stroh, F., Benter, T.: Studies of the mechanism of the cluster formation in a thermally sampling atmospheric pressure ionization mass spectrometer. Rev. Sci. Instrum. 85, 14102 (2014)CrossRefGoogle Scholar
  21. 21.
    Derpmann, V., Albrecht, S., Benter, T.: The role of ion-bound cluster formation in negative ion mass spectrometry. Rapid Commun. Mass Spectrom. 26, 1923–1933Google Scholar
  22. 22.
    Zook, D.R., Grimsrud, E.P.: Detection mass bias in atmospheric pressure ionization mass spectrometry. J. Am. Soc. Mass Spectrom. 2, 232–239 (1991)CrossRefGoogle Scholar
  23. 23.
    Kuhl, C., Tautenhahn, R., Böttcher, C., Larson, T.R., Neumann, S.: CAMERA: an integrated strategy for compound spectra extraction and annotation of liquid chromatography/mass spectrometry data sets. Anal. Chem. 84, 283–289 (2012)CrossRefGoogle Scholar
  24. 24.
    Broeckling, C.D., Afsar, F.A., Neumann, S., Ben-Hur, A., Prenni, J.E.: RAMClust: a novel feature clustering method enables spectral-matching-based annotation for metabolomics data. Anal. Chem. 86, 6812–6817 (2014)CrossRefGoogle Scholar
  25. 25.
    Mahieu, N.G., Spalding, J.L., Gelman, S.J., Patti, G.J.: Defining and detecting complex peak relationships in mass spectral data: the Mz.unity algorithm. Anal. Chem. 88, 9037–9046 (2016)CrossRefGoogle Scholar
  26. 26.
    Humbert, L., Maubert, M.A., Wolf, C., Duboc, H., Mahé, M., Farabos, D., Seksik, P., Mallet, J.M., Trugnan, G., Masliah, J., Rainteau, D.: Bile acid profiling in human biological samples: comparison of extraction procedures and application to normal and cholestatic patients. J. Chromatogr. B. 899, 135–145 (2012)CrossRefGoogle Scholar
  27. 27.
    Sarafian, M.H., Lewis, M.R., Pechlivanis, A., Ralphs, S., Mcphail, M.J.W., Patel, V.C., Dumas, M.-E., Holmes, E., Nicholson, J.K.: Bile acid profiling and quantification in biofluids using ultra- performance liquid chromatography tandem mass spectrometry. Anal. Chem. 87(19), 9662–9670 (2015)CrossRefGoogle Scholar
  28. 28.
    Wishart, D.S., Jewison, T., Guo, A.C., Wilson, M., Knox, C., Liu, Y., Djoumbou, Y., Mandal, R., Aziat, F., Dong, E., Bouatra, S., Sinelnikov, I., Arndt, D., Xia, J., Liu, P., Yallou, F., Bjorndahl, T., Perez-Pineiro, R., Eisner, R., Allen, F., Neveu, V., Greiner, R., Scalbert, A.: HMDB 3.0-the human metabolome database in 2013. Nucleic Acids Res. 41, (2013)Google Scholar
  29. 29.
    Wolff, J.C., Eckers, C., Sage, A.B., Giles, K., Bateman, R.: Accurate mass liquid chromatography/mass spectrometry on quadrupole orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 2. Applications using the dual-electrospray ion source. Anal. Chem. 73, 2605–2612 (2001)CrossRefGoogle Scholar
  30. 30.
    Eckers, C., Wolff, J.-C., Haskins, N.J., Sage, A.B., Giles, K., Bateman, R., Pharmaceuticals, S.B., Frontiers, N., Park, S., Avenue, T., Cm, E.: Accurate mass liquid chromatography / mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays . 1 . Proof of concept. Anal. Chem. 72, 3683–3688 (2000)CrossRefGoogle Scholar
  31. 31.
    Plumb, R.S., Johnson, K.A., Rainville, P., Smith, B.W., Wilson, I.D., Castro-Perez, J.M., Nicholson, J.K.: UPLC/MSE; a new approach for generating molecular fragment information for biomarker structure elucidation. Rapid Commun. Mass Spectrom. 20, 1989–1994 (2006)CrossRefGoogle Scholar
  32. 32.
    Madala, N.E., Steenkamp, P.A., Piater, L.A., Dubery, I.A.: Collision energy alteration during mass spectrometric acquisition is essential to ensure unbiased metabolomic analysis. In: Analytical and bioanalytical chemistry. pp. 367–372 (2012)Google Scholar
  33. 33.
    Rew, R., Davis, G.: NetCDF: An interface for scientific data access. IEEE Comput. Graph. Appl. 10, 76–82 (1990)CrossRefGoogle Scholar
  34. 34.
    Benton, H.P., Want, E.J., Ebbels, T.M.D.: Correction of mass calibration gaps in liquid chromatography–mass spectrometry metabolomics data. Bioinforma. Appl. Note 26, 2488–2489 (2010)Google Scholar
  35. 35.
    Smith, C.A., Want, E.J., O’maille, G., Abagyan, R., Siuzdak, G.: XCMS: processing mass spectrometry data for metabolite profiling using nonlinear peak alignment, matching, and identification. Anal. Chem. 78(3), 779–787 (2006)CrossRefGoogle Scholar
  36. 36.
    Tautenhahn, R., Bottcher, C., Neumann, S.: Highly sensitive feature detection for high resolution LC/MS. BMC Bioinformatics. 9, 504 (2008)CrossRefGoogle Scholar
  37. 37.
    R Core Development Team: R: a language and environment for statistical computing, 3.2.1, https://www.r-project.org/ (2016)
  38. 38.
    Stein, S.E., Scott, D.R.: Optimization and testing of mass-spectral library search algorithms for compound identification. J. Am. Soc. Mass Spectrom. 5, 859–866 (1994)CrossRefGoogle Scholar
  39. 39.
    Wan, K.X., Vidavsky, I., Gross, M.L.: Comparing similar spectra: from similarity index to spectral contrast angle. J. Am. Soc. Mass Spectrom. 13, 85–88 (2002)CrossRefGoogle Scholar
  40. 40.
    Juraschek, R., Dülcks, T., Karas, M.: Nanoelectrospray – more than just a minimized-flow electrospray ionization source. J. Am. Soc. Mass Spectrom. 10, 300–308 (1999)CrossRefGoogle Scholar
  41. 41.
    Schmidt, A., Karas, M., Dülcks, T.: Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: When does ESI turn into nano-ESI? J. Am. Soc. Mass Spectrom. 14, 492–500 (2003)CrossRefGoogle Scholar
  42. 42.
    Tang, K., Page, J.S., Smith, R.D.: Charge competition and the linear dynamic range of detection in electrospray ionization mass spectrometry. J. Am. Soc. Mass Spectrom. 15, 1416–1423 (2004)CrossRefGoogle Scholar
  43. 43.
    Alfaro, C.M., Uwakweh, A.O., Todd, D.A., Ehrmann, B.M., Cech, N.B.: Investigations of analyte-specific response saturation and dynamic range limitations in atmospheric pressure ionization mass spectrometry. Anal. Chem. 86, 10639–10645 (2014)CrossRefGoogle Scholar
  44. 44.
    Tang, L., Kebarle, P.: Dependence of ion intensity in electrospray mass spectrometry on the concentration of the analytes in the electrosprayed solution. Anal. Chem. 65, 3654–3668 (1993)CrossRefGoogle Scholar
  45. 45.
    Tang, K., Smith, R.D.: Physical/chemical separations in the break-up of highly charged droplets from electrosprays. J. Am. Soc. Mass Spectrom. 12, 343–347 (2001)CrossRefGoogle Scholar
  46. 46.
    Kebarle, P., Tang, L.: From ions in solution to ions in the gas phase – the mechanism of electrospray mass spectrometry. Anal. Chem. 65, 972A–986A (1993)Google Scholar
  47. 47.
    Gabelica, V., De Pauw, E.: Internal energy and fragmentation of ions produced in electrospray sources. Mass Spectrom. Rev. 24, 566–587 (2005)CrossRefGoogle Scholar
  48. 48.
    Brophy, P., Farmer, D.K.: Clustering, methodology, and mechanistic insights into acetate chemical ionization using high-resolution time-of-flight mass spectrometry. Atmos. Meas. Tech. 9, 3969–3986 (2016)CrossRefGoogle Scholar
  49. 49.
    Dziadosz, M.: Influence of buffer concentration on electrospray ionisation of γ-hydroxybutyrate adducts with the components of the mobile phase used in liquid chromatography-tandem mass spectrometry. J. Chromatogr. B. 1008, 240–241 (2016)CrossRefGoogle Scholar
  50. 50.
    Kamel, A.M., Brown, P.R., Munson, B.: Effects of mobile-phase additives, solution pH, ionization constant, and analyte concentration on the sensitivities and electrospray ionization mass spectra of nucleoside antiviral agents. Anal. Chem. 71, 5481–5492 (1999)CrossRefGoogle Scholar
  51. 51.
    Jaeger, C., Méret, M., Schmitt, C.A., Lisec, J.: Compound annotation in liquid chromatography/high-resolution mass spectrometry based metabolomics: robust adduct ion determination as a prerequisite to structure prediction in electrospray ionization mass spectra. Rapid Commun. Mass Spectrom. 31, 1261–1266 (2017)CrossRefGoogle Scholar

Copyright information

© American Society for Mass Spectrometry 2018

Authors and Affiliations

  • Patrick Brophy
    • 1
  • Corey D. Broeckling
    • 1
  • James Murphy
    • 2
  • Jessica E. Prenni
    • 1
  1. 1.Proteomics and Metabolomics FacilityColorado State UniversityFort CollinsUSA
  2. 2.Waters CorporationMilfordUSA

Personalised recommendations