Skip to main content
Log in

Plaque modification using a cutting balloon is more effective for stenting of heavily calcified lesion than other scoring balloons

  • Original Article
  • Published:
Cardiovascular Intervention and Therapeutics Aims and scope Submit manuscript

Abstract

Cutting balloons (CBs) and other scoring balloons are known to be useful for plaque modification in heavily calcified lesions. There have been some reports of the efficacy of these balloons compared to conventional balloons. However, there have been no reports exploring which balloon is most effective among these three types of balloons. We, therefore, compared these three balloons with respect to effectiveness in plaque modification of calcified lesions. We retrospectively investigated 201 cases using these three balloons from April 2015 to December 2017. Of these cases, 156 with severe calcified lesions that had undergone intravascular ultrasound (IVUS) or optical frequency domain imaging (OFDI) were enrolled. The ratio of severe calcified lesion was higher in the CB group than in the groups of other balloons (p = 0.001), and IVUS and OFDI showed that a CB was more effective in plaque modification than the other balloons. The acute gain (minimum stent diameter minus minimum lumen diameter) and acute cross-sectional area (CSA) gain (minimum stent area minus minimum lumen area) were both larger in the CB group than in the others, and the stent symmetry index (minimum stent diameter/maximum stent diameter) showed that the CB group more closely approximated a perfect circle than the other groups (p = 0.0001, 0.006 and 0.002 for the acute gain, acute CSA gain and the stent symmetry index). Similar results were obtained in cases without rotational atherectomy. These data suggest that CB is more effective for plaque modification in cases of severe calcified lesions than other scoring balloons.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

Abbreviations

PCI:

Percutaneous intervention

DES:

Drug-eluting stent

BMS:

Bare metal stent

CB:

Cutting balloon

FDI:

Optical frequency domain imaging

IVUS:

Intravascular ultrasound

CSA:

Cross-sectional area

References

  1. Madhavan MV, Tarigopula M, Mintz GS, Maehara A, Stone GW, Généreux P. Coronary artery calcification: pathogenesis and prognostic implications. J Am Coll Cardiol. 2014;63(17):1703–14.

    Article  CAS  PubMed  Google Scholar 

  2. Vliegenthart R, Oudkerk M, Hofman A, Oei HH, van Dijck W, van Rooij FJ, et al. Coronary calcification improves cardiovascular risk prediction in the elderly. Circulation. 2005;112:572–7.

    Article  PubMed  Google Scholar 

  3. Vavuranakis M, Toutouzas K, Stefanadis C, Chrisohou C, Markou D, Toutouzas P. Stent deployment in calcified lesions: can we overcome calcific restraint with high-pressure balloon inflations? Catheter Cardiovasc Interv. 2001;52(2):164–72.

    Article  CAS  PubMed  Google Scholar 

  4. Fitzgerald PJ, Ports TA, Yock PG. Contribution of localized calcium deposits to dissection after angioplasty. An observational study using intravascular ultrasound. Circulation. 1992;86(1):64–70.

    Article  CAS  PubMed  Google Scholar 

  5. Tan K, Sulke N, Taub N, Sowton E. Clinical and lesion morphologic determinants of coronary angioplasty success and complications: current experience. J Am Coll Cardiol. 1995;25(4):855–65.

    Article  CAS  PubMed  Google Scholar 

  6. Virmani R, Farb A, Burke AP. Coronary angioplasty from the perspective of atherosclerotic plaque: morphologic predictors of immediate success and restenosis. Am Heart J. 1994;127(1):163–79.

    Article  CAS  PubMed  Google Scholar 

  7. Moussa I, Ellis SG, Jones M, Kereiakes DJ, McMartin D, Rutherford B, Mehran R, et al. Impact of coronary culprit lesion calcium in patients undergoing paclitaxel-eluting stent implantation (a TAXUS-IV sub study). Am J Cardiol. 2005;96(9):1242–7.

    Article  PubMed  Google Scholar 

  8. Seo A, Fujii T, Inoue T, Onoda S, Koga A, Tanaka Y, et al. Initial and long-term outcomes of sirolimus-eluting stents for calcified lesions compared with bare-metal stents. Int Heart J. 2007;48(2):137–47.

    Article  PubMed  Google Scholar 

  9. Khattab AA, Otto A, Hochadel M, Toelg R, Geist V, Richardt G. Drug-eluting stents versus bare metal stents following rotational atherectomy for heavily calcified coronary lesions: late angiographic and clinical follow-up results. J Interv Cardiol. 2007;20(2):100–6.

    Article  PubMed  Google Scholar 

  10. Rathore S, Matsuo H, Terashima M, Kinoshita Y, Kimura M, Tsuchikane E, et al. Rotational atherectomy for fibro-calcific coronary artery disease in drug eluting stent era: procedural outcomes and angiographic follow-up results. Catheter Cardiovasc Interv. 2010;75(6):919–27.

    PubMed  Google Scholar 

  11. Kuntz RE, Safian RD, Carrozza JP, Fishman RF, Mansour M, Baim DS. The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting. Circulation. 1992;86(6):1827–35.

    Article  CAS  PubMed  Google Scholar 

  12. Vaquerizo B, Serra A, Miranda F, Triano JL, Sierra G, Delgado G, et al. Aggressive plaque modification with rotational atherectomy and/or cutting balloon before drug-eluting stent implantation for the treatment of calcified coronary lesions. J Interv Cardiol. 2010;23(3):240–8.

    Article  PubMed  Google Scholar 

  13. Tang Z, Bai J, Su SP, Lee PW, Peng L, Zhang T, et al. Aggressive plaque modification with rotational atherectomy and cutting balloon for optimal stent expansion in calcified lesions. J Geriatr Cardiol. 2016;13(12):984–91.

    CAS  PubMed  PubMed Central  Google Scholar 

  14. Li Q, He Y, Chen L, Chen M. Intensive plaque modification with rotational atherectomy and cutting balloon before drug-eluting stent implantation for patients with severely calcified coronary lesions: a pilot clinical study. BMC Cardiovasc Disord. 2016;16:112.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  15. Jinnouchi H, Kuramitsu S, Shinozaki T, Hiromasa T, Kobayashi Y, Takeji Y, et al. Five-year clinical outcomes after drug-eluting stent implantation following rotational atherectomy for heavily calcified lesions. Circ J. 2018;82(4):983–91.

    Article  PubMed  Google Scholar 

  16. Okura H, Hayase M, Shimodozono S, Kobayashi T, Sano K, Matsushita T, REDUCE Investigators, et al. Restenosis Reduction by Cutting Balloon Evaluation. Mechanisms of acute lumen gain following cutting balloon angioplasty in calcified and noncalcified lesions: an intravascular ultrasound study. Catheter Cardiovasc Interv. 2002;57(4):429–36.

    Article  PubMed  Google Scholar 

  17. Albiero R, Silber S, Di Mario C, Cernigliaro C, Battaglia S, Reimers B, RESCUT Investigators, et al. Cutting balloon versus conventional balloon angioplasty for the treatment of in-stent restenosis: results of the restenosis cutting balloon evaluation trial (RESCUT). J Am Coll Cardiol. 2004;43(6):943–9.

    Article  PubMed  Google Scholar 

  18. Ozaki Y, Yamaguchi T, Suzuki T, Nakamura M, Kitayama M, Nishikawa H, et al. Impact of cutting balloon angioplasty (CBA) prior to bare metal stenting on restenosis. Circ J. 2007;71(1):1–8.

    Article  PubMed  Google Scholar 

  19. de Ribamar Costa J, Jr Mintz GS, Carlier SG, Mehran R, Teirstein P, et al. Nonrandomized comparison of coronary stenting under intravascular ultrasound guidance of direct stenting without predilation versus conventional predilation with a semi-compliant balloon versus predilation with a new scoring balloon. Am J Cardiol. 2007;100(5):812–7.

    Article  Google Scholar 

  20. Kanda Y. Investigation of the freely available easy-to-use software ‘EZR’ for medical statistics. Bone Marrow Transplant. 2013;48(3):452–8.

    Article  CAS  Google Scholar 

  21. Barath P, Fishbein MC, Vari S, Forrester JS. Cutting balloon: a novel approach to percutaneous angioplasty. Am J Cardiol. 1991;68(11):1249–52.

    Article  CAS  PubMed  Google Scholar 

Download references

Funding

This research received no grant from any funding agency in the public, commercial or not-for-profit sectors.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ryuichi Matsukawa.

Ethics declarations

Conflict of interest

The author’s declare that they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Matsukawa, R., Kozai, T., Tokutome, M. et al. Plaque modification using a cutting balloon is more effective for stenting of heavily calcified lesion than other scoring balloons. Cardiovasc Interv and Ther 34, 325–334 (2019). https://doi.org/10.1007/s12928-019-00578-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12928-019-00578-w

Keywords

Navigation