Technical Evaluation and Optimization of Phasor Measurement Unit Using CSIR-NPL PMU Calibrator System to Ensure Reliability

  • Case Report
  • Published:
MAPAN Aims and scope Submit manuscript

Abstract

The technological enhancements and new startups in India have led to a tremendous increase in the power demand. The grids are being made smart, more efficient and reliable to meet not only the growing energy demands but also to prevent blackouts. The synchrophasor technology is evolving, explored and used by the power sectors for real-time measurements with phasor measurement unit (PMU) as the main elemental device. Industries developing PMUs must ensure that it should comply the IEEE C37.118.1-2011 and C37.118.1a-2014 synchrophasor standards, as the corrective action taken by power grid in real-time environment will depend on the PMU data. The optimization of PMU ensures that the measurement results are as per the IEEE synchrophasor standards leading to improvement in its performance. Here, we had evaluated the performance of an industrial PMU using CSIR-NPL PMU calibration system. The evaluation was done under static and dynamic conditions. This analysis represents the capability of PMU testing and calibration at CSIR-NPL and also ensures that the PMU that will be used in real time on the fields reports precise data. PMU-Cal facility can handle all the steady-state and dynamic-state tests for both M class and P class configured PMU at all desired frame rates. This system is traceable to its respective primary standards and is functional to cater the needs of power sector in terms of PMU calibration and testing.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

References

  1. https://www.ibef.org/download/Power-February-20181.pdf

  2. V. K. Agrawal, P. K. Agarwal and R. Kumar, Experience of commissioning of PMUs Pilot Project in the Northern Region of India, in: 16th National Power Systems Conference, India (2010)

  3. M. Adamiak, W. Premerlani and B. Kasztenny, Synchro phasors: definition, measurement, and application, in Proceedings of the 59th Annual Georgia Tech Protective Relaying, Atlanta, GA, pp. 27–29

  4. V. K. Agrawal, P. K. Agrawal and H. Rathour, Application of PMU Based Information in Improving the Performance of Indian Electricity Grid, in Proceedings of National power Systems Conference, India (2012)

  5. X. Wang, D. Shi, Z. Wang, C. Xu, Q. Zhang, X. Zhang and Z. Yu, Online calibration of phasor measurement unit using density-based spatial clustering, IEEE Trans. Power Deliv., 33(3) (2018) 1081–1090

    Article  ADS  Google Scholar 

  6. Y. Hu and D. Novosel, Progresses in PMU testing and calibration, in Proceedings of 3rd International Conference on Electric Utility Deregulation and Restructuring and Power Technologies, China (2008), pp. 150–155

  7. P. Komarnicki, C. Dzienis, Z. A. Styczynski, J. Blumschein and V. Centeno, Practical experience with PMU system testing and calibration requirements, in Proceedings of IEEE Power and Energy Society General Meeting, USA (2008) pp. 1–5

  8. K. Narendra, Z. Zhang, J. Lane, B. Lackey and E. Khan, Calibration and testing of TESLA phasor measurement unit (PMU) using double F6150 test instrument, in Proceedings of iREP Symposium—Bulk Power System Dynamics and Control—VII. Revitalizing Operational Reliability, USA (2007) pp. 1–13

  9. R. Sharma, A. K. Saxena, V. N. Ojha and P. C. Kothari, SI units (Monograph) [NPL, New Delhi] (2000) 17

  10. S. Yadav, A. Zafer, A. Kumar, N. D. Sharma and D. K. Aswal, Role of national pressure and vacuum metrology in indian industrial growth and their global metrological equivalence, MAPAN-J. Metrol. Soc India 33(4) (2018) 347–359

    Google Scholar 

  11. 6135A-PMU-brochure-Fluke

  12. IEEE Standard for Synchrophasor Measurements for Power Systems C37.118.1a-2014

  13. IEEE Standard for Synchrophasor Measurements for Power Systems C37.118.1a-2011

Download references

Acknowledgements

The authors would like to thank Dr. D. K. Aswal, Director CSIR-NPL for his guidance and kind permission to present this work. The authors would also like to thank Mr. Inder Mohan Sood (VCL) and Mr. Amreek Singh for their valuable contributions, technical discussions and all kinds of logistic support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Anish Bhargav.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bhargav, A., Ahmad, S., Kumari, S. et al. Technical Evaluation and Optimization of Phasor Measurement Unit Using CSIR-NPL PMU Calibrator System to Ensure Reliability. MAPAN 35, 117–124 (2020). https://doi.org/10.1007/s12647-019-00346-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12647-019-00346-4

Keywords

Navigation