Skip to main content
Log in

Experimental investigation on the suitability of flexible pressure sensor for wrist pulse measurement

  • Original Paper
  • Published:
Health and Technology Aims and scope Submit manuscript

Abstract

Pulse examination at the radial artery of the wrist is a most apparent diagnosis technique. Wrist pulse carries rich information about the cardiovascular system of human body. An investigation is made here to suggest suitable flexible type of thin film pressure sensor to measure the wrist pulse as per Ayurvedic medicine system. Primary objective of this work is to suggest a sensor which exhibits optimum spatial features and SNR values. Force Sensing Resistor (FSR), piezoresistive and piezoelectric thin film sensors are considered under this study. Piezoelectric sensor shows good performance in the quality of the pulse with 22 dB SNR. Further experimentation is conducted to find out transmissivity, repeatability and susceptibility to motion artifact. Trasnsmissivities of 0.91, 0.68 and 0.64 are obtained for piezoelectric, piezoresistive and FSR sensors respectively. Piezoresistive and FSR show repeatability error of ±8% and ± 7% while measuring pulse amplitude under standard force. Noise due to motion artifact for each type of sensors are recorded and compared with the standard Gaussian distribution function with the help of histogram. Collectively, piezoelectric sensor exhibits good spatial features, high transmissivity and comparatively low susceptibility to motion artifact.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12

Similar content being viewed by others

References

  1. Nakajima K, Tamura T, Miike H. Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering technique. Med Eng Phys. 1996;18(5):65–372.

    Article  Google Scholar 

  2. Mendelson Y, Ochs BD. Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography. IEEE Trans Biomed Eng. 1988;35(10):798–805.

    Article  Google Scholar 

  3. Lee QY, Chan GSH, Redmond SJ, Middleton PM, Steel E, Malouf P, et al. N. H. Lovell "classification of low systemic vascular resistance using photoplethysmogram and routine cardiovascular measurements" proc. Annu. Int Conf IEEE Eng Med Biol Soc. 2010:1930–3.

  4. Zhang A. H. Wang "real-time detection system for photoelectric pulse signals" proc. IEEE Int Conf Bus ManagElectron Inform. 2011:498–501.

  5. Doupis J, Papanas N, Cohen A, McFarlan L, Horton E. Pulse wave analysis by Applanation tonometry for the measurement of arterial stiffness. Open Cardiovasc Med J. 2016;10:188–95.

    Article  Google Scholar 

  6. Yoo SK, Shin KY, Lee TB, Jin SO. New pulse wave measurement method using different hold-down wrist pressures according to individual patient characteristics. SpringerPlus. 2013;2:406.

    Article  Google Scholar 

  7. Renevey P, Vetter R, Krauss J, Celka P, Depeursinge Y. Wrist-located pulse detection using IR signals activity and nonlinear artifact cancellation. Proc Annu Int Conf IEEE Eng Med Biol Soc. 2001;3:3030–3.

    Google Scholar 

  8. Kwak YH, Kim W, Park KB, Kim K, Seo S. Flexible heartbeat sensor for wearable device. Biosensors Bioelectron. 2017;94(15):250–5.

    Article  Google Scholar 

  9. Aritomo M, Yonezawa Y. A wrist-mounted activity and pulse recording system. In Proc of the First Joint BMES/EMBS Conf. 1999;2:693.

    Article  Google Scholar 

  10. Rangaprakash D, Narayana Dutt D. Study of wrist pulse signals using time domain spatial features. Comput Electr Eng. 2015;45:100–7.

    Article  Google Scholar 

  11. Hu C-S, Chung Y-F, Yeh C-C, Luo C-H. Temporal and spatial properties of arterial pulsation measurement using pressure sensor array. Evidence-Based Complementary Alternative Med. 2012;2012:1–9.

    Google Scholar 

  12. Joshi AB, Kalange AE, Bodas D, Gangal SA. Simulations of piezoelectric pressure sensor for radial artery pulse measurement. Mater Sci Eng B. 2010;168(1–3):250–3.

    Article  Google Scholar 

  13. Selvaraj N, Shelley KH, Silverman DG, Stachenfeld N, Galante N, Florian JP, et al. A novel approach using time frequency analysis of pulse-oximeter data to detect progressive hypovolemia in spontaneously breathing healthy subjects. IEEE Trans Biomed Eng. 2011;58(8):2272–9.

    Article  Google Scholar 

  14. Wang P, Zuo W, Zhang D. A compound pressure signal acquisition system for multichannel wrist pulse signal analysis. IEEE Trans Instrum Meas. 2014;63(6):1556–65.

    Article  Google Scholar 

  15. Zuo W, Wang P, Zhang D. Comparison of three different types of wrist pulse signals by their physical meanings and diagnosis performance. IEEE J Biomed Health Inform. 2016;20(1):119–27.

    Article  Google Scholar 

  16. Wang P, Zuo W, Zhang H, Zhang D. "Design and implementation of a multi-channel pulse signal acquisition system" proc. IEEE Int Conf Biomed Eng Informat. 2012:1063–7.

  17. Wang D, Zhang D, Lu G. A novel multichannel wrist pulse system with different sensor arrays. IEEE Trans Instrum Meas. 2015;64(7):2020–34.

    Article  Google Scholar 

  18. Mi X, Nakazawa F. A multipoint thin film polymer pressure/force sensor to visualize traditional medicine palpations. IEEE SENSORS 2014 Proc, Valencia. 2014:843–6.

  19. V. D. Lad Secrets of the Pulse Albuquerque NM USA:TheAyurvedic Press 1996.

  20. S. UpadhyayNadivijnana (Ancient pulse science).Chaukhambha Sanskrit Pratishthan Delhi 1986.

  21. Hankey A. Establishing the scientific validity of tridosha part 1: Dosha ,Subdosha and DoshaPrakritis. Anc Sci Life. 2010;20(3):6–18.

    Google Scholar 

  22. Joshi A, Kulkarni A, Chandran S, Jayaraman VK, Kulkarni BD. "NadiTarangini: a pulse based diagnostic system," 2007 29th annual international conference of the IEEE engineering in medicine and biology society. Lyon. 2007:2207–10.

  23. Abhinav MS, Kumar M, Anand S, Salhan A, Santhosh J. “Nadiyantra: a robust system design to capture the signals from the radial artery for non-invasive diagnosis,” in bioinformatics and biomedical engineering, 2008. ICBBE 2008. 2nd Int Conf. 2008:1387–90.

  24. Selvan T, Begum M. Nadiaridhal: A pulse based automated diagnostic system, in Electronics Computer Technology (ICECT). 3rd Int Conf. 2011;1:305–8.

    Google Scholar 

  25. Begum M, Poonguzhali R. “Noikanippaan: Nadi diagnosing system,” in recent trends in information technology (ICRTIT). Int Conf. 2011:1049–54.

  26. Kalange AE, Mahale BP, Aghav ST, Gangal SA. Nadiparikshanyantra and analysis of radial pulse, in physics and Technology of Sensors (ISPTS). 1st Int Symposium. 2012;2012:165–8.

    Google Scholar 

  27. N. Arunkumar K. M. M. Sirajudeen. Approximate entropy based ayurvedic pulse diagnosis for diabetics—A case study" Proc. IEEE Int Conf Trendz Inf Sci Comp. 133–135, 2011.

Download references

Funding

The work entitled does not have any type of funding from professional organization.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sukesh Rao M..

Ethics declarations

Conflict of interest

The authors Sukesh Rao M. & Rathnamala Rao have NO potential conflict of interest in Consultancies, Grants Fees, honoraria, Patents, Royalties, Stock or share ownership.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Rao M., S., Rao, R. Experimental investigation on the suitability of flexible pressure sensor for wrist pulse measurement. Health Technol. 9, 143–151 (2019). https://doi.org/10.1007/s12553-018-0264-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12553-018-0264-0

Keywords

Navigation