Duodenal perforations due to biliary stenting migration, although rare, can occur. We report a unique case of duodenal perforation due to a large in length plastic stent with no (or marginal) migration, which ended up in the root of the mesentery, explaining the normal laboratory values and minimal imaging findings observed. Any clinical symptom during the postprocedural period should raise the suspicion of a major complication and prompt quick management decisions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Soehendra N, Reynders-Frederix V. Palliative bile duct drainage—a new endoscopic method of introducing a transpapillary drain. Endoscopy. 1980;12:8–11.

    Article  CAS  PubMed  Google Scholar 

  2. ASGE Standards of Practice Committee, et al. The role of ERCP in benign diseases of the biliary tract. Gastrointest Endosc. 2015;81:795–803.

    Article  Google Scholar 

  3. Dumonceau JM, Tringali A, Blero D, et al. Biliary stenting: indications, choice of stents and results: European Society of Gastrointestinal Endoscopy (ESGE) clinical guideline. Endoscopy. 2012;44:277–98.

    Article  PubMed  Google Scholar 

  4. ASGE Standards of Practice Committee, et al. Adverse events associated with ERCP. Gastrointest Endosc. 2017;85:32–47.

    Article  Google Scholar 

  5. Johanson JF, Schmalz MJ, Geenen JE. Incidence and risk factors for biliary and pancreatic stent migration. Gastrointest Endosc. 1992;38:341–6.

    Article  CAS  PubMed  Google Scholar 

  6. Miller G, Yim D, Macari M, et al. Retroperitoneal perforation of the duodenum from biliary stent erosion. Curr Surg. 2005;62:512–5.

    Article  PubMed  Google Scholar 

  7. Fatima J, Baron TH, Topazian MD, et al. Pancreaticobiliary and duodenal perforations after periampullary endoscopic procedures: diagnosis and management. Arch Surg. 2007;142:448–54.

    Article  PubMed  Google Scholar 

  8. Arhan M, Odemiş B, Parlak E, et al. Migration of biliary plastic stents: experience of a tertiary center. Surg Endosc. 2009;23:769–75.

    Article  PubMed  Google Scholar 

  9. Bagul A, Pollard C, Dennison AR. A review of problems following insertion of biliary stents illustrated by an unusual complication. Ann R Coll Surg Engl. 2010;92:W27–31.

    Article  PubMed  Google Scholar 

  10. Namdar T, Raffel AM, Topp SA, et al. Complications and treatment of migrated biliary endoprostheses: a review of the literature. World J Gastroenterol. 2007;13:5397–9.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Konstantinos Ekmektzoglou.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Human/animal rights

All procedures followed were in accordance with the ethical standards of the responsible committee on human experimentation (institutional and national) and with the Helsinki Declaration of 1975, as revised in 2008(5).

Informed consent

Informed consent was obtained from the patients included in the study.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ekmektzoglou, K., Nikou, E., Apostolopoulos, P. et al. Size does matter: when a large plastic biliary stent ends up in the root of the mesentery. Clin J Gastroenterol 12, 102–105 (2019). https://doi.org/10.1007/s12328-018-0914-9