Effectiveness of contaminant confinement in office spaces equipped with ceiling personalized ventilation system

  • Research Article
  • Indoor/Outdoor Airflow and Air Quality
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

Creating a micro-environment around infected occupants constitutes an effective strategy in reducing contaminants spread insuring a relatively clean macroclimate decreasing the risk of infection for occupants circulating in an office space. In this work, the ability of ceiling personalized ventilation (CPV) system assisted by desk fans (DF) or chair fans (CF) was studied with respect to confining contaminants spread in typical office space while considering possible occupant shift. A 3D computational fluid dynamics (CFD) model was developed to simulate particle spread. The developed model was validated experimentally with respect to concentration values using a thermal manikin in a climatic chamber with controlled particle generation. A parametric study was followed to determine the effect of the occupant shift from CPV design position, the CPV+DF or CF configuration, and the canopy angle on confinement performance for minimal particle spread in the space. The CPV jet and diffusers’ flow canopy favored particle deposition within the microclimate region leading to their removal from indoor air. For no occupant shift, assisting the CPV jet by DF or CF was very efficient in particle confinement. However, in the cases of critical backward occupant shift, flow asymmetry was formed around the occupant leading to particle spread and leading to asymmetry attenuation when operated with CF. The highest particle confinement was obtained for a canopy angle of 45° for the case of CPV assisted by CF due to forming a recirculation zone between the CPV and jet diffusers; hence trapping particles and reducing their spread to the macroclimate. It was found that a total supply flow rate of 60 L/s for MV is required compared to 43.5 L/s for the optimal CPV design, for equivalent average particle concentration within the macroclimate zone at the critical generation plane, leading to 62% reduction in power consumption of the supply fan.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • ASME (2004). Addenda to ASME AG-1–2003 Code on Nuclear Air and Gas Treatment. New York: American Society of Mechanical Engineers.

    Google Scholar 

  • ASHRAE (2009). ASHRAE Handbook—Fundamentals. Atlanta: American Society of Heating Air-conditioning and Refrigeration Engineers.

    Google Scholar 

  • ASHRAE (2013). Ventilation for Acceptable Indoor Air Quality. ANSI/ASHRAE Standard 62.1-2013. Atlanta: American Society of Heating, Air-Conditioning and Refrigeration Engineers.

    Google Scholar 

  • ANSYS (2016). ANSYS Software 17.2. Available at http://www.ansys.com.

    Google Scholar 

  • Bolashikov ZD, Melikov AK, Kranek M (2009). Improved performance of personalized ventilation by control of the convection flow around an occupant’s body. ASHRAE Transactions, 115(2): 421–431.

    Google Scholar 

  • Bolashikov ZD, Melikov AK, Kranek M (2010). Control of the free convective flow around the human body for enhanced inhaled air quality: Application to a seat-incorporated personalized ventilation unit. HVAC&R Research, 16: 161–188.

    Article  Google Scholar 

  • Bolashikov ZD, Barova M, Melikov AK (2015). Wearable personal exhaust ventilation: Improved indoor air quality and reduced exposure to air exhaled from a sick doctor. Science and Technology for the Built Environment, 21: 1117–1125.

    Article  Google Scholar 

  • Brook RD, Franklin B, Cascio W, Hong Y, Howard G, Lipsett M, Luepker R, Mittleman M, Samet J, Smith SC, Tager I (2004). Air pollution and cardiovascular disease: A statement for healthcare professionals from the expert panel on population and prevention science of the American Heart Association. Circulation, 109: 2655–2671.

    Article  Google Scholar 

  • Bruce N, Perez-Padilla R, Albalak R (2000). Indoor air pollution in developing countries: A major environmental and public health challenge. Bulletin of the World Health Organization, 78: 1078–1092.

    Google Scholar 

  • Cermak R, Melikov AK, Forejt L, Kovar O (2006). Performance of personalized ventilation in conjunction with mixing and displacement ventilation. HVAC&R Research, 12: 295–311.

    Article  Google Scholar 

  • Chen F, Yu SCM, Lai ACK (2006). Modeling particle distribution and deposition in indoor environments with a new drift–flux model. Atmospheric Environment, 40: 357–367.

    Article  Google Scholar 

  • Chen Q, McDevitt JJ, Gupta JK, Jones BW, Mazumdar S, Poussou SB (2012). Infectious disease transmission in airliner cabins. Report No. RITE-ACER-CoE-2012-01.

    Google Scholar 

  • El-Fil B, Ghaddar N, Ghali K (2016). Optimizing performance of ceiling-mounted personalized ventilation system assisted by chair fans: Assessment of thermal comfort and indoor air quality. Science and Technology for the Built Environment, 22: 412–430.

    Article  Google Scholar 

  • Englert N (2004). Fine particles and human health—A review of epidemiological studies. Toxicology Letters, 149: 235–242.

    Article  Google Scholar 

  • Fanger PO, Lauridsen J, Bluyssen P, Clausen G (1988). Air pollution sources in offices and assembly halls, quantified by the olf unit. Energy and Buildings, 12: 7–19.

    Article  Google Scholar 

  • Guo H, Lee SC, Chan LY, Li WM (2004). Risk assessment of exposure to volatile organic compounds in different indoor environments. Environmental Research, 94: 57–66.

    Article  Google Scholar 

  • Habchi C, Ghali K, Ghaddar N (2015a). Displacement ventilation zonal model for particle distribution resulting from high momentum respiratory activities. Building and Environment, 90: 1–14.

    Article  Google Scholar 

  • Habchi C, Ghali K, Ghaddar N, Shihadeh A (2015b). Chair fanenhanced displacement ventilation for high IAQ: Effects on particle inhalation and stratification height. Building and Environment, 84: 68–79.

    Article  Google Scholar 

  • Habchi C, Chakroun W, Alotaibi S, Ghali K, Ghaddar N (2016a). Effect of shifts from occupant design position on performance of ceiling personalized ventilation assisted with desk fan or chair fans. Energy and Buildings, 117: 20–32.

    Article  Google Scholar 

  • Habchi C, Ghali K, Ghaddar N, Chakroun W, Alotaibi S (2016b). Ceiling personalized ventilation combined with desk fans for reduced direct and indirect cross-contamination and efficient use of office space. Energy Conversion and Management, 111: 158–173.

    Article  Google Scholar 

  • He C, Morawska, L, Hitchins J, Gilbert D (2004). Contribution from indoor sources to particle number and mass concentrations in residential houses. Atmospheric Environment, 38: 3405–3415.

    Article  Google Scholar 

  • Kaczmarczyk J, Melikov A, Bolashikov Z, Nikolaev L, Fanger PO (2006). Human response to five designs of personalized ventilation. HVAC&R Research, 12: 367–384.

    Article  Google Scholar 

  • Keblawi A, Ghaddar N, Ghali K (2011). Model-based optimal supervisory control of chilled ceiling displacement ventilation system. Energy and Buildings, 43: 1359–1370.

    Article  Google Scholar 

  • Klepeis NE, Nelson WC, Ott WR, Robinson JP, Tsang AM, Switzer P, Behar JV, Hern SC, Engelmann WH (2001). The National Human Activity Pattern Survey (NHAPS): A resource for assessing exposure to environmental pollutants. Journal of Exposure Analysis and Environmental Epidemiology, 11: 231–252.

    Article  Google Scholar 

  • Khalifa HE, Janos MI, Dannenhoffer JF 2009. Experimental investigation of reduced-mixing personal ventilation jets. Building and Environment, 44: 1551–1558.

    Article  Google Scholar 

  • Lo LJ, Novoselac A (2010). Localized air-conditioning with occupancy control in an open office. Energy and Buildings, 42: 1120–1128.

    Article  Google Scholar 

  • Makhoul A, Ghali K, Ghaddar N (2013a). Desk fans for the control of the convection flow around occupants using ceiling mounted personalized ventilation. Building and Environment, 59: 336–348.

    Article  Google Scholar 

  • Makhoul A, Ghali K, Ghaddar N, Chakroun W (2013b). Investigation of particle transport in offices equipped with ceiling-mounted personalized ventilators. Building and Environment, 63: 97–107.

    Article  Google Scholar 

  • Makhoul A, Ghali K, Ghaddar N (2013c). Low-mixing coaxial nozzle for effective personalized ventilation. Indoor and Built Environment, 24: 225–243.

    Article  Google Scholar 

  • Makhoul A, Ghali K, Ghaddar N (2013d). The energy saving potential and the associated thermal comfort of displacement ventilation systems assisted by personalised ventilation. Indoor and Built Environment, 22: 508–519.

    Article  Google Scholar 

  • Melikov AK (2004). Personalized ventilation. Indoor Air, 14(s7): 157–167.

    Article  MathSciNet  Google Scholar 

  • Melikov AK (2015). Human body micro-environment: The benefits of controlling airflow interaction. Building and Environment, 91: 70–77.

    Article  Google Scholar 

  • Morawska L (2006). Droplet fate in indoor environments, or can we prevent the spread of infection? Indoor Air, 16: 335–347.

    Article  Google Scholar 

  • Nazaroff WW (2004). Indoor particle dynamics. Indoor Air, 14(s7): 175–183.

    Article  Google Scholar 

  • Nguyen TA, Aiello M (2013). Energy intelligent buildings based on user activity: A survey. Energy and Buildings, 56: 244–257.

    Article  Google Scholar 

  • Nicas M, Nazaroff WW, Hubbard A (2005). Toward understanding the risk of secondary airborne infection: Emission of respirable pathogens. Journal of Occupational and Environmental Hygiene, 2: 143–154.

    Article  Google Scholar 

  • Russo JS, Dang TQ, Khalifa HE (2009). Computational analysis of reduced-mixing personal ventilation jets. Building and Environment, 44: 1559–1567.

    Article  Google Scholar 

  • Spengler JD, Sexton K (1983). Indoor air pollution: a public health perspective. Science, 221(4605): 9–17.

    Article  Google Scholar 

  • Sun W, Cheong KWD, Melikov AK (2012). Subjective study of thermal acceptability of novel enhanced displacement ventilation system and implication of occupants’ personal control. Building and Environment, 57: 49–57.

    Article  Google Scholar 

  • Sundell J (2004). On the history of indoor air quality and health. Indoor Air, 14(s7): 51–58.

    Article  Google Scholar 

  • Tashtoush B, Molhim M, Al-Rousan M (2005). Dynamic model of an HVAC system for control analysis. Energy, 30: 1729–1745.

    Article  Google Scholar 

  • Viegi G, Simoni M, Scognamiglio A, Baldacci S, Pistelli F, Carrozzi L, Annesi-Maesano I (2004). Indoor air pollution and airway disease. The International Journal of Tuberculosis and Lung Disease, 8: 1401–1415.

    Google Scholar 

  • Wang M, Lin CH, Chen Q (2012). Advanced turbulence models for predicting particle transport in enclosed environments. Building and Environment, 47: 40–49.

    Article  Google Scholar 

  • Yang B, Sekhar SC (2007). Three-dimensional numerical simulation of a hybrid fresh air and recirculated air diffuser for decoupled ventilation strategy. Building and Environment, 42: 1975–1982.

    Article  Google Scholar 

  • Yang B, Sekhar SC (2008). The influence of evenly distributed ceiling mounted personalized ventilation devices on the indoor environment. International Journal of Ventilation, 7: 99–112.

    Article  Google Scholar 

  • Yang B, Melikov AK, Sekhar SC (2009). Performance evaluation of ceiling mounted personalized ventilation system. ASHRAE Transactions, 115(2): 395–406.

    Google Scholar 

  • Yang B, Sekhar SC, Melikov AK (2010a). Ceiling-mounted personalized ventilation system integrated with a secondary air distribution system—A human response study in hot and humid climate. Indoor Air, 20: 309–319.

    Article  Google Scholar 

  • Yang B, Sekhar SC, Melikov AK (2010b). Ceiling mounted personalized ventilation system in hot and humid climate —An energy analysis. Energy and Buildings, 42: 2304–2308.

    Article  Google Scholar 

  • Yang B, Sekhar SC (2014). Interaction of dynamic indoor environment with moving person and performance of ceiling mounted personalized ventilation system. Indoor and Built Environment, 23: 920–932.

    Article  Google Scholar 

  • Yang J, Sekhar SC, Cheong D, Raphael B (2014). Performance evaluation of an integrated Personalized Ventilation–Personalized Exhaust system in conjunction with two background ventilation systems. Building and Environment, 78: 103–110.

    Article  Google Scholar 

  • Zhang Z, Chen Q (2006). Experimental measurements and numerical simulations of particle transport and distribution in ventilated rooms. Atmospheric Environment, 40: 3396–3408.

    Article  Google Scholar 

  • Zhang Z, Chen Q (2007). Comparison of the Eulerian and Lagrangian methods for predicting particle transport in enclosed spaces. Atmospheric Environment, 41: 5236–5248.

    Article  Google Scholar 

  • Zhang H, Arens E, Kim D, Buchberger E, Bauman F, Huizenga C (2010). Comfort, perceived air quality, and work performance in a low-power task–ambient conditioning system. Building and Environment, 45: 29–39.

    Article  Google Scholar 

  • Zhao B, Zhang Y, Li X, Yang X, Huang D (2004). Comparison of indoor aerosol particle concentration and deposition in different ventilated rooms by numerical method. Building and Environment, 39: 1–8.

    Article  Google Scholar 

  • Zhao B, Guan P (2007). Modeling particle dispersion in personalized ventilated room. Building and Environment, 42: 1099–1109.

    Article  Google Scholar 

  • Zhao B, Chen C, Tan Z (2009). Modeling of ultrafine particle dispersion in indoor environments with an improved drift flux model. Journal of Aerosol Science, 40: 29–43.

    Article  Google Scholar 

Download references

Acknowledgements

The authors would like to acknowledge the financial support of Kuwait Foundation for Advancement of Science (KFAS), Project No P314-35EM-01.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nesreen Ghaddar.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Alotaibi, S., Chakroun, W., Habchi, C. et al. Effectiveness of contaminant confinement in office spaces equipped with ceiling personalized ventilation system. Build. Simul. 11, 773–786 (2018). https://doi.org/10.1007/s12273-018-0437-9

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-018-0437-9

Keywords

Navigation