Advertisement

The Reliability of Polyvinylidene Fluoride Sensor for Intra- and Intersession Measurements

  • Roopa G. Manjunatha
  • Surya Prakash
  • Konandur Rajanna
Original Article
  • 14 Downloads

Abstract

A new nasal sensor has been designed using Polyvinylidene fluoride (PVDF) film using its piezoelectric property to measure nasal patency. The aim of this study is to determine the intra- and intersession reliability of the new PVDF nasal sensor measurement of unilateral and combined nasal parameters in a group of healthy subjects. Two identical nasal sensors: for right nostril (RN) and left nostril (LN) were designed using piezoelectric natured PVDF films. Twenty subjects were studied. To evaluate the repeatability, total three sets of PVDF sensor measurements were recorded, two sets were taken 5 min apart during same session without repositioning the PVDF nasal sensors and two more sets were taken during 1 h apart successively, by repositioning the PVDF nasal sensor. Intraclass correlation coefficients (ICC) of PVDF sensor measurements for intra- and intersession showed a high and greater repeatability over time for all the combined (mean) and unilateral (RN and LN) values. In both healthy and patients, ICC values for both intra- and intersession measurements were ≥ 0.80 confirming strong reliability and also almost all of the coefficients of variation for the same parameters were low (below 10%). PVDF sensor measurements showed good intra- and intersession repeatability and can be recommended for the objective monitoring of nasal patency during diagnosis and follow-up of conditions.

Keywords

PVDF nasal sensor Nasal patency Intra- and intersession repeatability Reliability 

Notes

Acknowledgements

Authors also thank Prof. NS Murthy and Ms. Radhika, Department of Biostatistics, M. S. Ramaiah Medical College, Bangalore, India for their valuable inputs and contributions.

Authors’ Contributions

RGM carried out the design and coordinated the study, participated in most of the experiments and prepared the manuscript. SP provided assistance for clinical data and expertise. All authors have read and approved the content of the manuscript. KR provided expertise in the design of the study, coordinated all the experiments and participated in manuscript preparation.

Compliance with Ethical Standards

Conflict of interest

The authors declare that they have no conflict of interests.

References

  1. 1.
    Scadding G, Hellings P, Alobid I, Bachert C, Fokkens W, van Wijk RG et al (2011) Diagnostic tools in Rhinology EAACI position paper. Clin Transl Allergy 1:2CrossRefPubMedPubMedCentralGoogle Scholar
  2. 2.
    Hilberg O, Jackson AC, Swift DL, Pedersen OF (1989) Acoustic rhinometry: evaluation of nasal cavity geometry by acoustic reflection. J Appl Physiol 66(1):295–303CrossRefPubMedGoogle Scholar
  3. 3.
    Kern EB (1981) Committee report on standardization of rhinomanometry. Rinology 19(4):231–236Google Scholar
  4. 4.
    Fairley JW, Durham LH, Ell SR (1993) Correlation of subjective sensation of nasal patency with nasal peak flow rate. Clin Otolaringol 18(1):19–22CrossRefGoogle Scholar
  5. 5.
    Chaaban M, Jacquelynne PC (2011) Assessing nasal air flow: options and utility. Proc Am Thorac Soc 8:70–78CrossRefPubMedGoogle Scholar
  6. 6.
    Pallanch JF, Mccaffrey TV, Kern EB (1993) Evaluation of nasal breathing function. In: Cummings CW, Fredrickson JM, Harher LA, Krause CJ, Shuller DE (eds) Otolaryngology—head and neck surgery, 2nd edn. Mosby-Year Book, St Louis, pp 1–59Google Scholar
  7. 7.
    Corey JP, Gungor A, Nelson R, Fredberg J, Lai V (1997) A comparison of the nasal cross-sectional areas and volumes obtained with acoustic rhinometry and magnetic resonance imaging. Otolaryngol Head Neck Surg 117(4):349–354CrossRefPubMedGoogle Scholar
  8. 8.
    Silkoff PE, Chakravorty S, Chapnik J, Cole P, Zamel N (1999) Reproducibility of acoustic rhinometry and rhinomanometry in normal subjects. Am J Rhinol 13(2):131–135CrossRefPubMedGoogle Scholar
  9. 9.
    Cheung EJ, Citardi MJ, Fakhri S, Cain J, Batra PS, Luong A (2010) Com-parison of optical rhinometry to acoustic rhinometry using nasal provocation testing with Dermatophagoides farinae. Otolaryngol Head Neck Surg 143(2):290–293CrossRefPubMedGoogle Scholar
  10. 10.
    Al Ahmari MD, Wedzicha JA, Hurst JR (2012) Intersession repeatability of acoustic rhinometry measurements in healthy volunteers. Clin Exp Otorhinolaryngol 5(3):156–160CrossRefPubMedPubMedCentralGoogle Scholar
  11. 11.
    Kawai H (1969) The piezoelectric of polyvinylidene fluoride. Jpn J Appl Phys 8(7):975–976CrossRefGoogle Scholar
  12. 12.
    Manjunatha RG, Rajanna K, Mahapatra DR, Prakash S (2014) Evaluation of polyvinylidene fluoride nasal sensor to assess deviated nasal septum in comparison with peak nasal inspiratory flow measurements. Am J Rhinol Allergy 28(1):e62–e67CrossRefPubMedGoogle Scholar
  13. 13.
    Manjunatha RG, Rajanna K, Mahapatra DR, Nayak MM, Krishnaswamy UM, Srinivasa R (2013) Polyvinylidene fluoride film based nasal sensor to monitor human respiration pattern: an initial clinical study. J Clin Monit Comput.  https://doi.org/10.1007/s10877-013-9486-x Google Scholar
  14. 14.
    Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33(1):159–174CrossRefPubMedGoogle Scholar
  15. 15.
    Starling-Schwanz R, Peake HL, Salome CM, Toelle BG, Ng KW, Marks GB, Lean ML, Rimmer SJ (2005) Repeatability of peak nasal inspiratory flow measurements and utility for assessing the severity of rhinitis. Allergy 60(6):795–800CrossRefPubMedGoogle Scholar

Copyright information

© Association of Otolaryngologists of India 2018

Authors and Affiliations

  • Roopa G. Manjunatha
    • 1
  • Surya Prakash
    • 2
  • Konandur Rajanna
    • 1
  1. 1.Department of Instrumentation and Applied PhysicsIndian Institute of ScienceBangaloreIndia
  2. 2.Department of Ear, Nose and ThroatM. S. Ramaiah Medical College and HospitalBangaloreIndia

Personalised recommendations