Comparison of model-based flow rate estimation methods in frequency-converter-driven pumps and fans

  • Original Article
  • Published:
Energy Efficiency Aims and scope Submit manuscript

Abstract

Fluid handling systems such as pump and fan systems are found to have a significant potential for energy efficiency improvements. To determine the energy-saving potential, there is a need for easily implementable methods to monitor the system output. This essential information provides an opportunity to identify inefficient operation of the fluid handling system and to control the output of the pumping system according to process needs. Model-based pump or fan monitoring methods implemented in variable-speed drives have proven to be able to give information on the system output without additional metering; however, the present model-based methods may not be usable or sufficiently accurate in the whole operation range of the fluid handling device. To apply model-based system monitoring in a wider selection of systems and to improve the accuracy of the monitoring, this paper proposes a new method for pump and fan output monitoring with variable-speed drives. The method uses a combination of already known operating point estimation methods. Laboratory measurements are used to verify the benefits and applicability of the improved estimation method, and the new method is compared with five previously introduced model-based estimation methods. According to the laboratory measurements, the new estimation method is the most accurate and reliable of the model-based estimation methods.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  • Ahonen, T., Tamminen, J., Ahola, J., Viholainen, J., Aranto, N., & Kestilä, J. (2010). Estimation of pump operational state with model-based methods. Energy Conversion and Management, 51(6), 1319–1325.

    Article  Google Scholar 

  • Ahonen, T., Tamminen, J., Ahola, J., & Niemelä, M. (2011). Accuracy study of frequency converter estimates used in the sensorless diagnostics of induction-motor-driven systems. In: Proceedings of the European Conference on Power Electronics and Applications, August 30–September 2, 2011, Birmingham, UK.

  • Ahonen, T., Tamminen, J., Ahola, J., & Kestila, J. (2012). Frequency-converter-based hybrid estimation method for the centrifugal pump operational state. Transactions on Industrial Electronics, 59(12), 4803–4809.

    Article  Google Scholar 

  • Binder, A. (2008). Potentials for energy saving with modern drive technology—a survey. In: Proceedings of international symposium power electronics electrical drives automation and motion 2008, June 11–13, 2008, Ischia, Italy.

  • da Costa Bortoni, E., de Almeida, R. A., & Viana, A. N. C. (2008). Optimization of parallel variable-speed-driven centrifugal pumps operation. Energy Efficiency, 1(3), 167–173.

    Article  Google Scholar 

  • de Almeida, A. T., Fonseca, P., Falkner, H., & Bertoldi, P. (2003). Market transformation of energy-efficient motor technologies in the EU. Energy Policy, 31(6), 563–575.

    Article  Google Scholar 

  • de Almeida, A. T., Ferreira, F. J. T. E., & Both, D. (2005). Technical and economical considerations in the application of variable-speed drives with electric motor systems. IEEE Transactions on Industrial Applications, 41(1), 136–144.

    Article  Google Scholar 

  • European Parliament (2009). Decision no 406/2009/EC of the European Parliament and of the Council of 23 April 2009 on the effort of member states to reduce their greenhouse gas emissions to meet the community’s greenhouse gas emission reduction commitments up to 2020 (“Effort Sharing Decision”).

  • Ferreira, F. J. T. E., Fong, J. A. C., & de Almeida, A. T. (2011). Ecoanalysis of variable-speed drives for flow regulation in pumping systems. IEEE Transactions on Industrial Electronics, 58(6), 2117–2125.

    Article  Google Scholar 

  • Hammo, S., & Viholainen, J. (2006). Providing flow measurement in parallel pumping systems from variable speed drives. World Pumps, 2006(483), 30–33.

    Article  Google Scholar 

  • ISO (2012) Industrial fans—tolerances, methods of conversion and technical data presentation. 13448 Standard. Geneva, ISO.

  • Kernan, D.J., Sabini, E.P., Ganzon, N.W., & Stavale, A.E. (2011). Method for determining pump flow without the use of traditional sensors. U.S. Patent no. 7,945,411 B2.

  • Liu, M. (2002). Variable speed drive volumetric tracking (VSDVT) for airflow control in variable air volume (VAV) systems. In: Proceedings of symposium of improving building systems in hot and humid climates 2002, May 20–22, 2002, Houston, Texas, USA.

  • Marchi, A., Simpson, R., & Ertugrul, N. (2012). Assessing variable speed pump efficiency in water distribution systems. Drinking Water Engineering and Science, 7, 47–65.

    Article  Google Scholar 

  • Muszýnski, P. (2010). Impeller pumps: relating η and n. World Pumps, 2010(7), 25–29.

    Article  Google Scholar 

  • Nash, J. N. (1996). Direct torque control, induction motor vector control without an encoder. IEEE Transactions on Industrial Applications, 33(2), 333–341.

    Article  Google Scholar 

  • Pumps, S. (2010). Centrifugal pump handbook (3rd ed.). New York: Elsevier. ISBN 978-0-7506-8612-9.

    Google Scholar 

  • Tamminen, J., Ahonen, T., Ahola, J., & Kestilä, J. (2011). Sensorless flow rate estimation in frequency-converter-driven fans. In: Proceedings of the European conference on power electronics and applications 2011, August 30–September 2, 2011, Birmingham, UK.

  • Viholainen, J., Tamminen, J., Ahonen, T., & Vakkilainen, E. (2011). Benefits of using multiple variable-speed-drives in parallel pumping systems. In: Proceedings of international conference on energy efficiency in motor driven systems 2011, September 2–4, 2011, Alexandria, Virginia, USA.

  • Viholainen, J., Tamminen, J., Ahonen, T., Ahola, J., Vakkilainen, E., & Soukka, R. (2013). Energy-efficient control strategy for variable speed-driven parallel pumping systems. Energy Efficiency, 6(3), 495–509.

    Article  Google Scholar 

  • Wang, G., & Liu, M. (2005). Development of power-head based fan airflow station. In: Proceedings of international conference for enhanced building operations, October 11–13, 2005, Pittsburgh, Pennsylvania, USA.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jussi Tamminen.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tamminen, J., Viholainen, J., Ahonen, T. et al. Comparison of model-based flow rate estimation methods in frequency-converter-driven pumps and fans. Energy Efficiency 7, 493–505 (2014). https://doi.org/10.1007/s12053-013-9234-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12053-013-9234-6

Keywords

Navigation